  1. Corrosion of steel bridge Girder anchor bolts

    … for this project were to explicitly define the anchor bolt corrosion problem in the state of Georgia and recommend action to the Georgia Department of Transportation. The bearing assembly of concern is the plate bearing assembly, in which carbon steel and/or bronze plates are anchored by either …

    gatech Repository record for Corrosion of steel bridge Girder anchor bolts (opens in a new tab)

  2. Reliability analysis of single-headed anchor bolts

    … for predicting the capacity of a single-headed anchor bolt embedded in plain concrete have been recommended in the United States. The capacities computed by these different recommendations, in some cases, differ significantly. The existing differences in current design criteria for anchor bolts …

    vt Repository record for Reliability analysis of single-headed anchor bolts (opens in a new tab)

  3. Turn-of-the-nut tightening of anchor bolts

    Double-nut anchor bolt systems are used in the erection of traffic signal poles, high-mast luminaries, and other highway appurtenances. An absence of a tightening standard for such systems decreases the confidence in their performance under fatigue loading. Past research has shown that a tightening …

    tamu Repository record for Turn-of-the-nut tightening of anchor bolts (opens in a new tab)

  4. Tightening the large diameter anchor bolts of sign, signal, and luminaire structures

    … are experiencing problems associated with loose anchor bolts used in support structures (e.g., overhead signs, high-mast light tower (HMLT), and tall traffic signals). Specifically, MnDOT inspection crews have found loose nuts at most anchor bolt locations, even at some newly installed signs. …

    iastate Repository record for Tightening the large diameter anchor bolts of sign, signal, and luminaire structures (opens in a new tab)

  5. Evaluation of the anchor bolt clearance discrepancies apply for any anchor bolt connections

    … distance (a.k.a. stand-off distance) of the anchor bolt for double-nut moment joints is the distance between the bottom of the leveling nut and the top of concrete foundation. Previous research has investigated the effect of different loading conditions on the behavior of anchor bolts that …

    uab Repository record for Evaluation of the anchor bolt clearance discrepancies apply for any anchor bolt connections (opens in a new tab)

  6. Estudo de bases de pilares metálicos pelo método dos elementos finitos

    … it has been created models using either hooked anchor bolts and thread rods with an end welded nut embedded in the concrete. It was observed in this work the influence of the thickness of a base plate in thebehavior of the components of a steel column base (column, base plate, anchor bolts and …

    brazil-ufmg Repository record for Estudo de bases de pilares metálicos pelo método dos elementos finitos (opens in a new tab)

  7. An analytical and experimental study of the dynamic response of a press

    … response of a bolted press, one with loosened anchor bolts, and one which is isolated. Press performance, in terms of acceleration of the press, velocity of its foundation, and forces transmitted to the foundation, is analyzed in relation to the foundation mass and the stiffness of the …

    must-thes Repository record for An analytical and experimental study of the dynamic response of a press (opens in a new tab)

  8. Response of Continuous Steel I-Girder Bridges Subject to Temperature Variation

    … elements (piercaps, bearing assemblies, bearing anchor bolts). The potential effects of restrained thermal deformation in steel I-girder bridges have not been clearly demonstrated. Additionally, the method provided in AASHTO specifications for orienting guided expansion bearings on horizontally …

    wvu Repository record for Response of Continuous Steel I-Girder Bridges Subject to Temperature Variation (opens in a new tab)

  9. Análise do comportamento e determinação da resistência de chumbadores ancorados em blocos de concreto submetidos a forças horizontais.

    … particular situation of an isolated bolt and two bolts anchored in a concrete block. So, the mathematic formulation of beams on infinite elastic supports is presented, thus simulating the behavior of the anchored bolt. The formulas for calculating the contact strains between curved bodies are …

    brazil-ufmg Repository record for Análise do comportamento e determinação da resistência de chumbadores ancorados em blocos de concreto submetidos a forças horizontais. (opens in a new tab)

  10. Development of Lambda Factors for Masonry Design with Lightweight Grout

    … to normal weight (NW) grout by conducting anchor bolt tests, modulus of rupture tests, diagonal tensile strength tests, and lap splice tests. Two types of lightweight aggregates, expanded clay aggregates (EC) and expanded slate (ES) aggregates, are separately used to make the lightweight …

    clemson Repository record for Development of Lambda Factors for Masonry Design with Lightweight Grout (opens in a new tab)

  11. Stopper-Bearing System – A Solution to Displacement Control of Bridge Decks

    … damaged critical components such as bearings and anchor bolts. To this end, a new bearing system, referred to as a stopperbearing system (SBS), is proposed as one solution to address the vulnerability of bridge bearings and other components. The horizontal displacement of a deck can be limited to …

    tamu Repository record for Stopper-Bearing System – A Solution to Displacement Control of Bridge Decks (opens in a new tab)

  12. Seismic design and retrofit of coupled walls using structural steel

    … plates using structural epoxy and mechanical anchor bolts are investigated. A method for determining the influence of the steel plate retrofit on the shear capacity of the beam is developed. Non-linear dynamic analyses comparing the structural responses of unretrofitted and retrofitted …

    mcgill Repository record for Seismic design and retrofit of coupled walls using structural steel (opens in a new tab)

  13. Theoretical analysis of channel type anchors subjected to pure tensile or pure shear loads

    <p>The use of channel anchors in concrete building construction is relatively new. Although the pullout or shear capacity of single short anchor bolts or welded studs can be reasonably predicted using the concrete failure cone method, a similar pullout or shear capacity prediction relationship has …

    ut-knoxville Repository record for Theoretical analysis of channel type anchors subjected to pure tensile or pure shear loads (opens in a new tab)

  14. Performance and Design Approaches for Perforated Light-frame Wood Shear Walls

    … displacement, and forces in the hold-downs, anchor bolts, and straps. The scope of this study included a literature review of the theoretical background and prior experimental studies, instrumentation plan, construction and physical testing of specimens, data reduction, and a numerical and …

    sdstate Repository record for Performance and Design Approaches for Perforated Light-frame Wood Shear Walls (opens in a new tab)

  15. Evaluation of the Performance of Bridge Steel Pedestals under Low Seismic Loads

    … and lack of adequate connection details for anchor bolts is assessed experimentally and analytically. Full-scale reversed cyclic quasi-static experimental tests are conducted on a 40' bridge specimen rehabilitated with 19" and 33" steel pedestals to determine the modes of deformation and …

    gatech Repository record for Evaluation of the Performance of Bridge Steel Pedestals under Low Seismic Loads (opens in a new tab)

  16. Performance of FRP components and connections for bridge deck systems.

    … results than coupon level results. Mechanical (anchor-bolts) and epoxy adhesive connections, used to connect deck and stringers, exhibited 50% and 85% joint efficiencies, respectively. However, low mechanical connector stiffness limited the composite action between deck and stringers to 39%. …

    wvu Repository record for Performance of FRP components and connections for bridge deck systems. (opens in a new tab)

  17. SIMULATION AND PERFORMANCE OF STEEL SHEET SHEATHED SHEAR WALLS IN CFS-FRAMED BUILDING SYSTEMS

    … magnitude of gravity loads, spacing of shear anchor bolts, track bending rigidity, and presence of a ledger track or finish system were studied with respect to the wall line lateral performance. A parametric study on various wall line configurations based on real building archetype design …

    jhu Repository record for SIMULATION AND PERFORMANCE OF STEEL SHEET SHEATHED SHEAR WALLS IN CFS-FRAMED BUILDING SYSTEMS (opens in a new tab)

  18. Seismic response of uplifting liquid storage tanks

    … the seismic response of uplifting tanks. Both unanchored tanks and partially anchored tanks for which the number of anchor bolts at the base is insufficient to ensure full fixity are considered. The responses examined include the hydrodynamic pressures, the base uplift at critical locations, the …

    rice Repository record for Seismic response of uplifting liquid storage tanks (opens in a new tab)

  19. Assessment of Analytical Procedures for Designing Metal Buildings for Wind Drift Serviceability

    … stiffness even in case of single row of bolts. Moreover, using a two-dimensional (planar) structural model for analysis ignores any load distribution provided by roof and wall sheeting. Simulation of true behavior of base connection and diaphragm stiffness can substantially reduce drift …

    vt Repository record for Assessment of Analytical Procedures for Designing Metal Buildings for Wind Drift Serviceability (opens in a new tab)

  20. Influence of Column-Base Fixity On Lateral Drift of Gable Frames

    … connection contained base plate, column stub, anchor bolts and in some cases grout as its components. The model was mainly subjected to three load cases, namely gravity, wind and gravity plus wind. After performing many analyses, the influence of flexibility of each component on the flexibility …

    vt Repository record for Influence of Column-Base Fixity On Lateral Drift of Gable Frames (opens in a new tab)