Showing 1 to 16 of 16 for “"Andersen Cascade Impactor"”.
-
Metody testování inhalátorů
… was characterised using both the Next Generation Impactor and Andersen cascade Impactor, the regional deposition was assessed using a 3D printed airway replica of the human respiratory tract. The obtained results are discussed in terms of measurement methodology and compared with computational …
-
Optimizing the development and analysis of solution based metered dose inhalers
… Sizer (APS) used in conjunction with Model 3320 Impactor Inlet was evaluated for analysis of solution metered dose inhalers. The Model 3320 APS series provides rapid aerodynamic size distribution data and coupled with Model 3306 Impactor Inlet allows for the chemical analysis of the Inlet port, …
-
Current Challenges for the Development of Inhaled Medicines
… and Survanta. Lung dose was established using an Andersen cascade impactor and novel methods were developed to collect the aerosol and perform dissolution assays. The solubility and dissolution data were integrated into a physiologically-based pharmacokinetic model (Mimetikos Preludium) to …
-
Numerical Analysis of Respiratory Aerosol Deposition: Effects of Exhalation, Airway Constriction and Electrostatic Charge
… of an aerosol size sampler, an eight-stage Andersen cascade impactor (ACI) was numerically analyzed. The numerical simulations indicated high non-uniformity and recirculation in the flow field. Numerical predictions of retention fraction matched well with existing experiments (0.5 11% …
-
Electrical Behavior of Non-Aqueous Formulations: Role of Electrostatic Interactions in Pressurized Metered Dose Inhalers (pMDIs)
… pMDIs as calibration aerosols with a reference Andersen cascade impactor. The mean cut-off diameters for stages 4-12 obtained following recalibration of the modified ELPI were 0.44, 0.56, 0.70, 1.01, 1.40, 2.12, 3.03, 4.75, 6.37 μm, respectively in comparison to those reported by the …
-
INFLUENCE OF ELECTROSTATIC CHARGE UPON THE DEPOSITION BEHAVIOR OF PHARMACEUTICAL AEROSOLS WITHIN CASCADE IMPACTORS
Cascade impactors, routinely used for in vitro particle size characterization of pharmaceutical aerosols, are calibrated using dilute, charge-neutralized, monodisperse aerosols. But pharmaceutical aerosols are known to generate concentrated, inherently charged, polydisperse aerosol clouds. A …
-
Discovery and Characterization of Small Molecule Inhibitors of Biofilm Formation in Pseudomonas Aeruginosa
… showed outstanding distributive properties in an Andersen cascade impactor model of lung-targeted drug delivery, highlighting the potential of these chelators as nebulized agents to combat P. aeruginosa in Cystic Fibrosis. Previous research showed that production of excess rhamnolipids in P. …
-
IN VITRO MODELS FOR INHALED CORTICOSTEROID (ICS) AEROSOLS: A STUDY OF THEIR BIOPHARMACEUTICS AND PHARMACOLOGY
… (ICSs) is complex, comprised of a cascade of aerosol deposition and dissolution, followed by cellular uptake for local pharmacological action. This project hypothesized that the kinetics of dissolution for certain ICS aerosols generated from inhaler products were kinetically …
-
Developing a method to sample potential resuspension of radioactive contaminants near the former Rocky Flats Technical Plant
… regard to particle size fraction, the use of a cascade impactor to separate aerosols by size can be utilized to relate how deep varied-sized particles might penetrate the human respiratory tract after inhalation. This would not only indicate the presence of radionuclides but also the deposition …
-
Particle size characterization of virus-laden aerosols and evaluation of an electrostatic precipitator to reduce viral airborne transmission
… in pigs under experimentally conditions.The Andersen cascade impactor (ACI) is an air sampler that collects and separates airborne particles into different size intervals. However, particles may bounce upon impact with the collection plates of the ACI and deposit onto the lower stages, …
-
Viral aerosol survivability, Transmission, and sampling in an environmental chamber
… performance of the eight-stage non-viable Andersen cascade impactor was tested first. All six viruses were sampled for one and six hours at 25 deg C and 50% RH. The six-hour samples did not show much higher live virus titers than the one-hour samples, suggesting significant inactivation in …
-
Relative Bio-Equivalence of Salbutamol MDIs Without and With the Attached Spacers. Development and validation of novel HPLC methods for the determination of salbutamol (and terbutaline) in urine excreted post-inhalation for bioequivalence and pharmacokinetic studies of Salbutamol MDIs
… critical quality attributes of the MDI using an Andersen cascade impactor (ACI) were examined and included measurement of fine particle dose (FPD) and total delivered dose (TDD). Bioequivalence studies were conducted in humans using the urinary pharmacokinetic method. Post-inhalation urinary …
-
Μελέτη μεταλλικών ιχνηθετών τα αιωρούμενα σωματίδια για την εκτίμηση των πηγών ατμοσφαιρικής ρύπανσης
… were measured simultaneously using a six-stage Andersen cascade impactor. The obtained results were: • The most important aerosol sources were soil, marine aerosol, industry and motor vehicles • PCA and APCA could not clearly identify and quantify aerosol sources • PMF identified satisfactorily …
-
Desenvolvimento e caracterização de um novo sistema microparticulado contendo polímero catiônico para a administração pulmonar da dapsona e avaliação toxicológica em modelos animais in vivo
A pneumonia causada por Pneumocystis carinii (PCP) é uma das principais doenças oportunistas que acomete pacientes portadores do vírus HIV. Segundo dados da Organização Mundial da Saúde, cerca de 80 - 85% das pessoas portadoras do vírus sofrem de PCP. Essa infecção é pulmonar e o agente patológico …
-
A STUDY ON PARTICLE SURFACE ROUGHNESS AND ITS IMPACT ON TABLET AND INHALER TECHNOLOGY
Powder flow is an integral component in pharmaceutical manufacturing. Various powder flow methodologies were examined and correlated with each other using lactose of various shape and size. In-die powder flow during tableting was studied using lactose particles of different surface roughness. …
-
Inhalátory a nebulizátory pro použití v medicíně: principy, spolehlivost a provozní parametry
Problematika inhalačnej liečby je veľmi komplexnou problematikou a hoci je v posledných desaťročiach aktívne diskutovanou témou, jej rozvoj vo viacerých smeroch je viac než žiadaný. Prvá časť tejto práce predstavuje teoretický úvod do princípov takejto terapie a z nich vyplývajúcich požiadaviek na …