Showing 1 to 20 of 101 for “"Anemometers"”.
-
Temperature-Compensated Calibration and Measurements with Cross-Style Hotwire Anemometers
… collected using constant-temperature hotwire anemometers (CTAs) are known to be sensitive to variation in the ambient fluid temperature. Various calibration techniques are detailed in literature for temperature compensation of single-component velocity measurements using single-normal …
-
The Accuracy of Cup Anemometers for Field Wind Speed Measurements
… of the sign of the normalized difference between anemometers, ranging from -45.18% to 15.19%. The data processing involved the synchronization of both data logging systems, the removal of measurements affected by shadowing and the restriction to a significant wind speed regime, i.e. above the …
-
Euler-Bernoulli Implementation of Spherical Anemometers for High Wind Speed Calculations via Strain Gauges
… hot-wire, and recent developments with sphere anemometers. Several measurement methods have modeled the air drag force as a quadratic function of the corresponding wind speed. Furthermore, by incorporating non-drag fluid forces in addition to the main drag force, a dynamic set of equations of …
-
Flying Anemometers: Performance Assessment of a Miniaturized Sonic Anemometer for Measuring Wind from a Drone
… the performance of new miniaturized sonic anemometers for use onboard small aerial drones for meteorological measurements. Drones have received considerable attention as they provide a flexible vantage point for measuring in-situ atmospheric conditions. Specifically, drones equipped with …
-
Development of a disturbance observer for wind estimation by multirotor drone using machine learning
… quadrotor in proximity to two reference anemometers. Four ML models are developed: a long-short-term-memory (LSTM) neural network, an artificial-neural-network, a gated-recurrent-unit (GRU) neural network, and a Gaussian-process-regression. These models are trained with variations in …
-
COMPARISON OF OPTICAL TURBULENCE PREDICTION MODELS
… optical turbulence over many months using sonic anemometers that served as the baseline to compare prediction from the models. Atmospheric parameters such as air temperature, wind speed, humidity at two different heights as well as solar flux and ground temperature were simultaneously collected. …
-
C-130 testings on low-rising buildings
… speed measurement especially when the wind speed anemometers were close to the buildings. When wind speed anemometers were behind the building, the measured wind speed decreased almost 50%. When wind speed anemometers were in the front of windward walls, the recorded wind speed was about 10-15% …
-
Quantifying the effects of airflow distortion on anemometer wind speed measurements from merchant ships
Anemometers on Voluntary Observing Ships (VOS) are usually located above the bridge in a region where the effects of air flow distortion, created by the presence of the ship, may be large. Until now it was not known whether measurements from such anemometers would be biased high or low, and the …
-
Study of the atmospheric boundary layer processes over sloping terrain covered by sparse canopy
… to calibrate flux sensors (i.e., ultrasonic anemometers), and subsequently into three N-W Italy vineyards fields, collecting long term turbulent flux observations over the canopy. Bulk and higher order statistics are explored from these dataset to investigate the turbulent properties of the …
-
Heated anemometry and thermometry in water
… of two conical constant temperature hot film anemometers. In order to understand the behaviour of probes alone, thermal models of these sensors have been developed. The models incorporate a Nusselt number governed steady heat flux from the wetted surface and the thermal effects of a surface …
-
A thermistor based sensor for flow measurement in water
… which is a major problem for all thermal anemometers that operate in water. The calibration relation that is normally used for thermistor anemometers has been improved upon and gives better results than any found in the literature. In order to provide electrical isolation from the water …
-
Laminar boundary layer separation in oscillating flow.
… experimentally investigated. Multiple hotwire anemometers were used to obtain instantaneous boundary layer velocity profiles on a model in an oscillating freestream. Certain instantaneous profile behavior was found to be uniquely related to wake formation, while nonwake- inducing transient flow …
-
A hot-wire anemometer study of free turbulent mixing in axial, pressure gradients
… a single normal wire and an X-array hot-wire anemometers. The resulting hot-wire data shown in Figures 1-80 present an excellent visual representation of the physical aspects of turbulent flow. An analysis of the results of this experiment show conclusively that the Reynolds Stresses in the …
-
Experiments on Ekman layer instability.
… instabilities of the Ekman layer using hot wire anemometers. The apparatus consisted of two parallel circular rotating plates forming a spool; the air was admitted through screens at the outer edge and removed through a screen cage at the hub. In the Ekman layers formed on the inner surfaces of …
-
Comparison of measured and calculated flow properties after the rotating cascades of a three-stage axial-flow compressor.
… by measurements with flow probes and hot-wire anemometers. The tests were conducted on a 3-stage axial flow compressor of the Turbo-Propulsion Laboratory at the Naval Postgraduate School. Measurements were made over the entire operating range of the compressor at a fixed rotor speed of about …
-
Calibration of Hot-Film X-Probes for High Accuracy Angle Alignment in Wind Tunnels
… thesis investigates the use of hot-film thermal anemometers to align a plate on a wind tunnel at Hill Air Force Base that is used to calibrate Angle of Attack Transmitters on F-16s. A reoccurring problem with this wind tunnel is that no two instruments can verify an angle reading of the the …
-
Observations of atmospheric turbulence during a low intensity surface fire
… using a 4 by 4 array of three-dimensional sonic anemometers mounted on four trusses at 2.5 m right above the fuel bed level. The analysis of the 10-Hz velocity and temperature data from the 16 sonic anemometers focuses on fire-induced atmospheric turbulence. By comparing the observations …