Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 52 for “"Annular gap"”

  1. Evaluating ASCE MOP 145 Annular Gap Impact on Existing Standards for Non-Reinforced Cured-in-Place Pipe

    … of this paper was to evaluate the impact of annular gap on non-reinforced cured-in-place pipe (CIPP) required liner thickness using the American Society of Civil Engineers’ (ASCE) Manual of Practice 145 (ASCE MOP 145) equations for comparison against existing North American design, …

    ohiolink Repository record for Evaluating ASCE MOP 145 Annular Gap Impact on Existing Standards for Non-Reinforced Cured-in-Place Pipe (opens in a new tab)

  2. Ordering of particulate suspensions in Couette flow at moderate Reynolds numbers

    … of the order of or greater than one in the annular gap of a Couette type shearing device. This particulate ordering was observed and studied with both suspensions of rigid spheres and suspensions of polystyrene latex aggregates formed in the presence of shear within the gap. Each of these …

    ubc Repository record for Ordering of particulate suspensions in Couette flow at moderate Reynolds numbers (opens in a new tab)

  3. Fluid mechanics of intrathecal drug delivery

    … period. The subarachnoid space is modeled as an annular gap of constant or slowly varying cross section into which a catheter is introduced. The cerebrospinal fluid is replaced by water of 37°C which has very similar properties. This fluid in the annular gap is subjected to oscillations of …

    epfl Repository record for Fluid mechanics of intrathecal drug delivery (opens in a new tab)

  4. A numerical study on backfilling of the tail void with two-component grout based on laboratory tests

    In mechanized tunneling the annular gap between the segmental lining and the surrounding soil caused by tunnel driving must be backfilled instantaneously with an adequate mortar. The annular gap is caused due to the conical shape, overcut and design of the shield. The soft ground tunneling has a …

    poli-torino Repository record for A numerical study on backfilling of the tail void with two-component grout based on laboratory tests (opens in a new tab)

  5. Ground Movements Around Model Tunnels in Sand (Settlements, Shield, Photogrammetry)

    … out of the test bin in several steps and an annular gap between the two tubes simulated the tail void in an advancing shield. Three-dimensional development of ground movements was observed. In the L-series a movable roof section was lowered progressively to simulate yield of the tunnel roof …

    uiuc Repository record for Ground Movements Around Model Tunnels in Sand (Settlements, Shield, Photogrammetry) (opens in a new tab)

  6. Development of an apparatus to measure the thermal conductivity of polymer melts

    … method with guard heaters was used and the annular gap was 0.075 inch. The polymer was melted in a cylindrical melt chamber, then metered to the thermal conductivity measuring apparatus. Cartridge heaters provided heat input and temperature measurements were made with calibrated, …

    vt Repository record for Development of an apparatus to measure the thermal conductivity of polymer melts (opens in a new tab)

  7. Modelling, Design Optimization and Control of Magnetorheological Dampers for Prosthetic Applications

    … coil magneto-rheological (MR) fluid damper with annular gap for a prosthetic leg application. Based on Bingham plastic characteristics for MR fluids a quasi-static modeling of MR damper is developed to estimate the generated damping force of the damper. Analytical magnetic circuit analysis based …

    concordia

  8. Turbulent flow in concentric and eccentric annuli

    The turbulent flow of air through the annular gap between two tubes was studied experimentally, both with the tubes concentric and with the inner tube at eccentricities of 50% and 100%. Air velocities were measured using small traversable impact tubes. The shear stresses on the boundaries were …

    ubc Repository record for Turbulent flow in concentric and eccentric annuli (opens in a new tab)

  9. Polarimetric Models of Circumstellar Discs Including Aggregate Dust Grains

    … however recent PDI has shown the existence of an annular gap. In addition to this, the annular gap is found not to be devoid of dust. This then led to the construction of a four-component disc structure. Estimates of the mass of dust in the gap (2:10 10�6 M ) are made as well as for the planet ( …

    herts-thes Repository record for Polarimetric Models of Circumstellar Discs Including Aggregate Dust Grains (opens in a new tab)

  10. Measurement of Thermal Accommodation and Temperature Jump Coefficients Between Stainless Steel and Rarefied Helium

    … to study rarefied gas heat transfer through an annular gap of 1 mm, and to measure the thermal accommodation coefficient at the interface between stainless-steel and rarefied helium. The thermal accommodation and temperature jump coefficients are used to characterize the interaction between gas …

    unr Repository record for Measurement of Thermal Accommodation and Temperature Jump Coefficients Between Stainless Steel and Rarefied Helium (opens in a new tab)

  11. Cavity-enhanced jetting sound produced by a baffled piston

    … an aperture of a baffle, the flow within the annular gap between the piston and the baffle is opposite in phase, which causes a reduction in the radiated sound. That is, the acoustic power is always less than in the absence of a leaking edge flow. However, when the piston is backed by a …

    bu Repository record for Cavity-enhanced jetting sound produced by a baffled piston (opens in a new tab) Embargoed until 2999-01-01

  12. Molecular weight and concentration dependence of the thermal conductivity of polystyrene in benzene

    … the thermal conductivity of viscous liquids. The annular gap was 0.052 inches and guard heaters were employed to minimize end losses and distortion of the steady-state temperature distribution at the ends. The apparatus was calibrated with three liquids of known thermal conductivity, water, …

    vt Repository record for Molecular weight and concentration dependence of the thermal conductivity of polystyrene in benzene (opens in a new tab)

  13. Characterization and application of vortex flow adsorption for simplification of biochemical product downstream processing

    … the whole process. Vortex flow occurs in the annular gap between an inner rotating solid cylinder and an outer stationary cylindrical shell. Above a critical rotation rate, circular Couette flow bifurcates to a series of counter-rotating toroidal vortices. By suspending adsorbent resin in the …

    mit Repository record for Characterization and application of vortex flow adsorption for simplification of biochemical product downstream processing (opens in a new tab)

  14. An Investigation of a Pressure Controlled Fluidic Value Used for Controlling the Volume of the Human Bladder of a Catheterized Patient

    … poppet, inside a cylinder, which established an annular flow between the poppet and cylinder, while the valve was in the open position. The analysis and experimentation examined two diverse annular flow conditions. First, the case when the poppet positioned itself concentrically with respect to …

    ucf Repository record for An Investigation of a Pressure Controlled Fluidic Value Used for Controlling the Volume of the Human Bladder of a Catheterized Patient (opens in a new tab)

  15. Nonlinear Dynamics of Rotating Detonation Waves

    … comprised of concentric cylinders whereby the annular gap between the cylinders constitutes the flow domain. The annular gap acts as geometric confinement suitable for robustly promoting the self-steepening of pressure and density gradients caused by combustion. The RDE’s steady operation is …

    washington Repository record for Nonlinear Dynamics of Rotating Detonation Waves (opens in a new tab)

  16. Onset of flow instability and critical heat flux in horizontal, thin, uniformly- heated annuli

    … to determine the OFI and CHF behavior of annular channels with hydraulic diameters on the order of two millimeters (annular gap widths of approximately 1.0 mm). The OFI data were then compiled and used to create two correlations; one comparing OFI heat flux to saturation heat flux and the …

    nps Repository record for Onset of flow instability and critical heat flux in horizontal, thin, uniformly- heated annuli (opens in a new tab)

  17. Design of a pintle injector

    … of 3 different pintle angles and 2 different annular gap thickness. Non-dimensional parameters from literature are used to determine water and air mass flow rates of cold flow experiments. Phase Doppler Particle Analyzer (PDPA) is utilized to obtain droplet Sauter mean diameters (SMD) and …

    metu Repository record for Design of a pintle injector (opens in a new tab)

Page 1 of 3