Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Anthropomorphic Test Device (ATD)"”.

  1. Human male and female biodynamic response to underwater explosion events.

    … data and video footage recorded during live fire testing were used to generate and validate ATB models for both a seated and a standing Hybrid III Anthropomorphic Test Device (ATD). Subsequently, these models were used to estimate the biodynamic response and injury potentials for both male and …

    nps Repository record for Human male and female biodynamic response to underwater explosion events. (opens in a new tab)

  2. Development and Validation of a Finite Element Dummy Lower Limb Model for Under-body blast Applications

    … (UBB) refers to the use of a roadside explosive device to target a vehicle and its occupants. During Operation Iraqi Freedom, improvised explosive devices (IEDs) accounted for an estimated 63% of US fatalities. Furthermore, advancements in protective equipment, combat triage, and treatment have …

    vt Repository record for Development and Validation of a Finite Element Dummy Lower Limb Model for Under-body blast Applications (opens in a new tab)

  3. Development of a Modified Anthropomorphic Test Device for the Quantification of Behind Shield Blunt Impacts

    … extremely short duration. This work modified an Anthropomorphic Test Device (ATD) to be used for the characterization of behind ballistic shield blunt impact loading profiles. The modified ATD was instrumented to measure impacts at the hand, wrist, forearm, and elbow to compare the force transfer …

    mcmaster Repository record for Development of a Modified Anthropomorphic Test Device for the Quantification of Behind Shield Blunt Impacts (opens in a new tab)

  4. A methodology utilizing spatial kinematics principles with angular rate sensor and accelerometer data to evaluate ATD head and leg flail kinematics in experimental aerospace seat dynamic impact testing

    In dynamic aircraft crash testing, the head trajectory of an anthropomorphic test device (ATD) is typically recorded by photometric analysis from the high-speed video. While photometric analysis can provide useful data results, it does have a number of short comings including the need to correct …

    wichita-thes Repository record for A methodology utilizing spatial kinematics principles with angular rate sensor and accelerometer data to evaluate ATD head and leg flail kinematics in experimental aerospace seat dynamic impact testing (opens in a new tab)

  5. Biomechanics Of Concussion: The Importance Of Neck Tension

    … dizziness, and blurred vision. In the Hybrid III anthropomorphic test device (ATD), the upper neck load cell is in close proximity to the human brain stem. This study found that the additional mass of a football helmet onto the Hybrid III headform increases the upper neck forces and moments in …

    wayne-thes Repository record for Biomechanics Of Concussion: The Importance Of Neck Tension (opens in a new tab)

  6. Investigation of head and neck injury risk associated with short-distance falls in 12 month old children.

    … experimentally simulated using an instrumented anthropomorphic test device (ATD) representing a 12-month-old child. Three different falls heights, five different impact surfaces, and two levels of joint stiffness were tested to determine their effect on injury risk. Linear head accelerations …

    louisville Repository record for Investigation of head and neck injury risk associated with short-distance falls in 12 month old children. (opens in a new tab)

  7. Biomechanical tools for assessing foot and ankle injury risk in frontal automotive collisions

    … the axial impact response of two commonly used Anthropomorphic Test Device (ATD) lower legs, under altered ankle postures. Both posture and ATD model were found to affect the load distribution on the foot, highlighting the need to establish injury limits for non-neutral postures as well as …

    mcmaster Repository record for Biomechanical tools for assessing foot and ankle injury risk in frontal automotive collisions (opens in a new tab)

  8. INJURY RISK TO THE UPPER EXTREMITY RESULTING FROM BEHIND SHIELD BLUNT TRAUMA

    … from these events. In this research, an anthropomorphic test device (ATD) was modified to allow for additional instrumentation capable of measuring these loads. It was then used in a ballistic testing facility to quantify loading at the hand, wrist, forearm, and elbow. A lightweight …

    mcmaster Repository record for INJURY RISK TO THE UPPER EXTREMITY RESULTING FROM BEHIND SHIELD BLUNT TRAUMA (opens in a new tab)

  9. QUANTIFYING THE EFFECT OF USER SIZE ON INJURY TOLERANCE OF THE UPPER EXTREMITY SUBJECTED TO BEHIND-SHIELD BLUNT TRAUMA

    … release of the shield, placing those behind the device at risk. This injury mechanism is known as behind-shield blunt trauma (BSBT). Previous studies investigating these interactions have used testing conditions not representative of those present during these behind-shield events and lacked …

    mcmaster Repository record for QUANTIFYING THE EFFECT OF USER SIZE ON INJURY TOLERANCE OF THE UPPER EXTREMITY SUBJECTED TO BEHIND-SHIELD BLUNT TRAUMA (opens in a new tab)

  10. Development of an active anti-whiplash automotive seat to reduce whiplash injuries following a rear-end collision

    … in this dissertation was to design, build and test a novel Experimental anti-whiplash automotive seat to prevent whiplash injuries following low-speed, rear-end collisions. The key safety features of the Experimental seat included the dynamic control of seat hinge rotation and seatback cushion …

    ubc Repository record for Development of an active anti-whiplash automotive seat to reduce whiplash injuries following a rear-end collision (opens in a new tab) Download PDF for Development of an active anti-whiplash automotive seat to reduce whiplash injuries following a rear-end collision (opens in a new tab)

  11. Optimization Of Underbody Blast Energy-Attenuating Seat Mechanisms Using Modified Madymo Hybrid Iii And Human Body Models

    … and designated blast severity. Using Hybrid III anthropomorphic test device (ATD) and post-mortem human surrogate (PMHS) data from the University of Virginia in a sub-injurious Condition A (4 m/s seat velocity) and injurious Condition B (10 m/s seat velocity), this research is summarized in the …

    wayne-thes Repository record for Optimization Of Underbody Blast Energy-Attenuating Seat Mechanisms Using Modified Madymo Hybrid Iii And Human Body Models (opens in a new tab)

  12. Biomechanics and injury assessment of household falls in children : clinical, anthropomorphic surrogate, and computer simulation studies.

    … fall assessments, fall simulations using an anthropomorphic test device (ATD), and development/validation of a computer simulation model used to investigate sensitivity of injury outcome measures to fall environment and child surrogate parameters. Overall, the risk of severe or …

    louisville Repository record for Biomechanics and injury assessment of household falls in children : clinical, anthropomorphic surrogate, and computer simulation studies. (opens in a new tab)

  13. Lower Extremity Biomechanical Response of Female and Male Post-Mortem Human Surrogates to High-Rate Vertical Loading During Simulated Under-Body Blast Events

    … blast (UBB) event, an improvised explosive device (IED) delivers a high-energy blast beneath a military vehicle, exposing mounted Warfighters to considerable risk of severe lower extremity injuries. Loftis and Gillich (2014) determined that the lower leg and ankle region is the most common …

    vt Repository record for Lower Extremity Biomechanical Response of Female and Male Post-Mortem Human Surrogates to High-Rate Vertical Loading During Simulated Under-Body Blast Events (opens in a new tab)

  14. Investigating the likelihood of pediatric femur fracture due to falls through finite element analysis.

    … a previously study measured using a 12-month old anthropomorphic test device (ATD) in experimentally simulated household falls. A FE femur model was derived from a CT scan performed on an 11-month old child. Validation of the FE model was conducted through mechanical testing of a bone surrogate …

    louisville Repository record for Investigating the likelihood of pediatric femur fracture due to falls through finite element analysis. (opens in a new tab)

  15. Cervical Spine Tolerance And Response In Compressive Loading Modes Including Combined Compression And Lateral Bending

    … have observed noticeable lateral bending of the anthropomorphic test device (ATD) neck prior to or in conjunction with head impact with the vehicle roof in rollover crash tests. Since there is scant data available about the effects of lateral bending on overall compressive tolerance of the human …

    wayne-thes Repository record for Cervical Spine Tolerance And Response In Compressive Loading Modes Including Combined Compression And Lateral Bending (opens in a new tab)

  16. Rear impact crashworthiness of a manual WC19 wheelchair occupied by a 50th percentile ATD.

    … part of the study, several rear impact sled tests were performed with a commercial, WC19, manual wheelchair in its original configuration. The wheelchair occupant was represented by a midsized male anthropomorphic test device (ATD) and the sled tests were carried out according to the proposed …

    louisville Repository record for Rear impact crashworthiness of a manual WC19 wheelchair occupied by a 50th percentile ATD. (opens in a new tab)

  17. Automation and Standardisation of Seatbelt Routing for Crash Analysis: Additional studies on the influence of the initial shoulder belt position on ATDs and HBMs chest injury metrics in frontal collision simulations

    … an individual, lead to difficulties in comparing test results. This study aims to standardise and automate the process of seatbelt creation, significantly reducing the time input while ensuring reproducibility. The project was carried out using the Finite Element pre-processor ANSA from BETA CAE …

    chalmers Repository record for Automation and Standardisation of Seatbelt Routing for Crash Analysis: Additional studies on the influence of the initial shoulder belt position on ATDs and HBMs chest injury metrics in frontal collision simulations (opens in a new tab)

  18. Biomechanical Responses of Small Female Human Surrogates during Frontal Sled Tests using a Realistic Vehicle Environment

    … The THOR 5th-percentile female (THOR-05F) anthropomorphic test device (ATD) was developed to represent a small female occupant better than the Hybrid III 5th percentile female (HIII-05F) ATD. However, the two ATDs have not been compared to post-mortem human surrogate (PMHS) responses using …

    vt Repository record for Biomechanical Responses of Small Female Human Surrogates during Frontal Sled Tests using a Realistic Vehicle Environment (opens in a new tab)

  19. Anti-Rotation Load Leg Effects on Crash Injury Metrics Under Child Restraint System Misuse

    … other internal organs). Although anti-rotational devices, such as load legs, have shown potential in mitigating injury metrics, their efficacy for rear-facing infant CRS misuse conditions and condition combinations remains underexplored. Therefore, this research aimed to evaluate the use of load …

    ttu Repository record for Anti-Rotation Load Leg Effects on Crash Injury Metrics Under Child Restraint System Misuse (opens in a new tab)

  20. Simulated Automobile and Rotary-Wing Aircraft Impacts: Dynamic Neck Response after Surgical Treatment for Cervical Spondylosis

    … aircraft impact with the ground using both an anthropomorphic test device (ATD) and a human body model. The head and neck response of the ATD FE simulation was successfully validated against the results of a previously conducted experimental sled test. A more biofidelic head and neck response …

    vt Repository record for Simulated Automobile and Rotary-Wing Aircraft Impacts: Dynamic Neck Response after Surgical Treatment for Cervical Spondylosis (opens in a new tab)

Page 1 of 2