Implementation of An Anthropomorphic Phantom For The Evaluation of Proton Therapy Treatment Procedures
… thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient …
-
A Dosimetric Study of a VMAT Head and Neck Treatment Plan Using TLDs and Gafchromic Films
… EBT2 Gafchromic films have been used in side an anthropomorphic phantom for this dosimetric study. These two dosimeters have been used to determine the dose in specific points and to compare the results with the computer plan. Also, EBT2 films have been used to study the isodose distribution on …
-
A new standard in testing mattresses for use in x-ray imaging : developing, validating and using a novel method to test x-ray mattresses for pressure ulcer development, radiation dosimetry and image quality
… has three aims (1). to develop and validate an anthropomorphic-phantom-based method of assessing X-ray table mattress IP as an index of mattress performance; (2) to assess X-ray table mattress pressure redistribution properties; and (3) to evaluate mattress radiation attenuation characteristics …
-
TASK SPECIFIC EVALUATION METHODOLOGY FOR CLINICAL FULL FIELD DIGITAL MAMMOGRAPHY
… blur and anti-scatter grid performance using an anthropomorphic phantom. Additionally we intend to provide a limited evaluation of the effects that image processing in clinical FFDM has in signal detectability. <bold>Methodology</bold>: We explored different strategies and a variety of …
-
PERFORMANCE OPTIMIZATION OF SEMI-STATIONARY CT FOR WHOLE BODY IMAGING
… developed to evaluate performance using multiple phantoms of increasing complexity, including the ACR 464 phantom and an anthropomorphic phantom. System modeling included the acquisition geometry, source spectrum, detector response, and energy-dependent attenuation properties. The results show …
-
Development of A Remote Dosimetric Audit Framework For Carbon Therapy
… and combine these tools to create an end-to-end anthropomorphic phantom audit. The absorbed dose corrections factors for TLD and OSLD will be characterized in a therapeutic carbon beam, as will a variety of plastics typically used in phantom dose measurements. An anthropomorphic phantom, …
-
In-Vivo Ct Dosimetry During Virtual Colonoscopy
… with TLDs during simulated VC within a modified anthropomorphic phantom configured to represent three sizes of patients undergoing VC. The measured rectal doses decreased in an exponential manner with increasing phantom effective diameter, with R<sup>2</sup>=0.993 for the exponential regression …
-
Development of A Ct Metal Artifact Management Algorithm For Proton Therapy Planning (Ampp) For Head and Neck Cancer Patients
… distortion and HU accuracy) using a geometrical phantom simulating a HN patient with dental fillings. A HN anthropomorphic phantom composed of proton tissue equivalent materials, human skull, air cavities was used to perform a quantitative image quality comparison between AMPP and four major CT …
-
Prototipinės brachiterapijos planavimo įrangos kūrimas /
… of the absorbed dose in target material (of phantom or patient‘s body) during brachytherapy planning procedures. The procedure of forehand calibration of the dosimetry detectors has been invented and a Python programming packet for implementation of this procedure has been created. The …
-
Simulation and Analysis of Human Phantoms Exposed to Heavy Charged Particle Irradiations Using the Particle and Heavy Ion Transport System (PHITS)
Anthropomorphic phantoms are commonly used for testing radiation fields without the need to expose human subjects. One of the most widely known is RANDO phantom. This phantom is used primarily for medical X-ray applications, but a similar design known as "MATROSHKA" is now being used for space …
-
Estimating the exposure to first receivers from a contaminated victim of a radiological dispersal device detonation
… from the victim. The victim was modeled as an anthropomorphic phantom using the BodyBuilder program. A thin layer of source material was added to the surface of the phantom’s skin to simulate whole-body contamination. The computer code MCNP5 was used to tally the doses to the individual organs …
-
Influência de blindagens de sala de radioterapia na dose efetiva de pacientes submetidos ao tratamento de câncer de próstata
… accelerator (15 MV), a radiotherapy room and an anthropomorphic phantom in voxels. The simulation of the linear accelerator was carried out based on the information of documents provided by the manufacturer Varian and validated, comparing the simulated results to those obtained by the Golden Data …
-
Developing RF safety strategies at high field and ultra-high field MRI
… in a bilateral DBS configuration using an anthropomorphic phantom to accurately estimate heating near the electrical contacts for varying bilateral trajectories. Chapter 3 extends this validation to in vivo and postmortem swine models, accounting for tissue heterogeneity and perfusion …
-
Developing RF safety strategies at high field and ultra-high field MRI
… in a bilateral DBS configuration using an anthropomorphic phantom to accurately estimate heating near the electrical contacts for varying bilateral trajectories. Chapter 3 extends this validation to in vivo and postmortem swine models, accounting for tissue heterogeneity and perfusion …
-
Detector Photon Response and Absorbed Dose and Their Applications to Rapid Triage Techniques
… Sr-90 and Am-241. Through the use of a MAX phantom along with a few Simulink MATLAB programs, a good anthropomorphic phantom was created for use in MCNPX simulations that would provide organ doses from internally deposited radionuclides. Ludlum model 44-9 and 44-2 detectors were used to …
-
The Use of 3D-Printed Phantoms For Evaluating CT Image Quality
… has the potential to create a paradigm shift in phantom design from simple geometrical objects to more sophisticated structures that incorporate anatomical features. Phantoms are used as surrogates for humans when evaluating the performance of CT imaging systems, but traditional molding …
-
Reducing the Radiation Dose to Women Receiving Cardiac CT Scans
… (Milwaukee, WI) were used to create voxelized phantom models for the computer simulation. Experimental measurements were performed with an anthropomorphic phantom on a clinical CT scanner (Discovery CT750HD, GE Healthcare, Chalfont St. Gilates, England). For both simulation and experimental …
-
Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems
… and measurements. A simple clinical case with an anthropomorphic phantom was used to test MCSquare end-to-end. This work further characterized the secondary neutral particles present in a collimated minibeam system as well as the impact the collimator has on linear energy transfer (LET). Overall, …
-
Fluence Field Modulated Computed Tomography
… interest. Simulation studies using a simulated anthropomorphic phantom of the chest suggest an average dose reduction of at least 20% compared to conventional techniques is possible, where local dose reductions may be greater than 60%. Across different imaging tasks and objects, integral dose …
-
Characterization of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms
… assurance program for protons, and for remote anthropomorphic phantom irradiations. The OSLDs used were aluminum oxide (Al2O3:C) nanoDots from Landauer, Inc. (Glenwood, Ill.) measuring 10x10x2 mm3. A square, 20(L)x20(W)x0.5(H) cm3 piece of solid water was fabricated with pockets to allow OSLDs …