Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 31 for “"Anti-islanding"”
-
Anti-islanding schemes for machine-based distributed generation
The most common method of detecting the islanding in a machine-based distributed generator (DG) is to establish an under/over frequency and under/over voltage window within which a synchronous DG is allowed to operate. When such a DG is islanded from the utility system, the frequency or voltage …
-
Designing Anti-islanding Detection Using the Synchrophasor Vector Processor
ABSTRACT Designing Anti-Islanding Detection Using the Synchrophasor Vector Processor Ruth Huang The need for distributed generation (DG) has become more and more popular because of the adverse effects of fossil fuels and the fear of running out of fossil fuels. By having DG, there are less …
-
Stability Impacts of Sandia Frequency Shift Anti-Islanding on a Grid-Connected Inverter
… through an inverter. To prevent an unintentional islanding condition, these inverters employ a variety of anti-islanding protection schemes. The Sandia Frequency Shift (SFS) method of anti-islanding protection is considered to be the most effective scheme built into grid-connected inverters. Much …
-
Enhancing reliability in passive anti-islanding protection schemes for distribution systems with distributed generation
… enhance the reliability of conventional passive anti-islanding protection scheme in distribution systems embedding distributed generation. This approach uses an Islanding-Dedicated System (IDS) per phase which will be logically combined with the conventional scheme, either in blocking or …
-
Investigation of anti-islanding schemes for utility interconnection of distributed fuel cell powered generations
… One of the most challenging problems is known as islanding phenomenon. This situation occurs when a network is disconnected from utility grid and is energized by local DFPGs. It can possibly result in injury to utility personnel arriving to service isolated feeders, equipment damage, and system …
-
A novel zonal adaptive DG anti-islanding protection scheme to enhance future system stability using real-time inertia estimates
… issues. With particular attention given to the anticipated reduction and variation of system inertia, concerns are growing with respect to power system frequency stability following large disturbances. This is attributed to the potential involvement of acceleration and magnification in frequency …
-
Διερεύνηση της λειτουργίας αντιστροφέων για τη διασύνδεση διεσπαρμένων μονάδων παραγωγής με το δίκτυο χαμηλής τάσης
… dissertation is to thoroughly investigate the anti-islanding capabilities of grid-connected inverters under the high penetration of distributed energy sources (DES) in low-voltage grids.Grid-connected distributed energy sources have been intensively developed over the last decade, increasing …
-
Islanding issues associated with photovoltaic inverters
… networks is the concern over possible islanding, i.e., when a disconnected part of the power network remains energized by the connected PV systems for a significant time interval. Islanding is undesirable for a number of reasons including safety hazards to utility personnel; and …
-
The safety risk assessment and mitigation measures of the LV networks with embedded generators.
… power flow from installed PV systems should the anti-islanding protection fail after the loss of utility supply. This research investigation presents results from the analyses of the impact of statutory requirement, load demand and load type on the embedded generator (EG) grid–tied inverter …
-
Setting frequency relays and voltage relays to protect synchronous distributed generators against islanding and abnormal frequencies and voltages
… are investigated for their implication for the anti-islanding setting of the frequency relay. Results reveal that the effect of these factors must be considered when setting the relay for islanding detection. For the voltage relay, results reveal that the effect of active and reactive powers …
-
Islanding Detection in Power Systems
… There are a number of different kinds of anti-islanding or loss-of-mains protections. Some are implemented in practice while others are still on a research level. This thesis provides an analysis of benefits and drawbacks of methods that are applied today. The ability of the different …
-
A study of voltage regulation and islanding associated with distributed generation
… of DG: the voltage regulation and the islanding phenomenon; The study shows the introduction of A DG may cause an over-voltage problem in some segment along the distribution line. The level of over-voltage depends on the size and location of the DGs. Furthermore, DGs are known to impair …
-
EXPANSION OF DYNAMIC SIMULATION MODEL FOR A DISTRIBUTED GENERATOR UNINTENTIONAL ISLANDING DETECTION SCHEME
… protective relaying, power quality, and islanding detection. For this reason IEEE established standard IEEE 1547 that ensures the compliance with such requirements and it will help formulate technical specifications for grid interconnection with Distributed Generator (DG) resources. In …
-
Multi-machine synchronous islanding utilizing synchrophasor measurements
… three iteration of single machine synchronous islanding. Each iteration was tested within a physical laboratory. The multi-machine synchronous island control scheme features a novel load-sharing scheme which successfully protects the participating generators from motor mode …
-
Analysis and Design of Phase Lock Loop Based Islanding Detection Methods
… thesis discusses the grid interface issue of anti-islanding. An electric island occurs when a circuit breaker in the electric power system trips. The distributed resource should disconnect from the electric grid for safety reasons. This thesis will give an overview of the possible methods. …
-
Study of the Wide Area Network (WAN) Method of Islanding Prevention at the Distribution Level
In power systems, the term "islanding" refers to a condition that occurs when V parts of the power system separate from one another to form "islands". Islanding itself is not necessarily a problem, but unintentional islanding could pose a risk to equipment integrity and to personnel safety. Small …
-
Transient And Distributed Algorithms To Improve Islanding Detection Capability Of Inverter Based Distributed Generation
… into distribution networks. The problem of islanding detection and islanding prevention (i.e. anti-islanding) has stimulated a lot of research due to its role in severely compromising the safety of working personnel and resulting in equipment damages. Various Islanding Detection Methods …
-
Real-time modelling and simulation of distribution system protection with and without renewable distribution generation.
… are provided and implementation of anti-islanding techniques achieved.