Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 3009 for “"Aortic"”.

  1. AORTIC STIFFNESS MODIFICATIONS AFTER ENDOVASCULAR AORTIC REPAIR

    Background: Endovascular aortic repair (EVAR and TEVAR) has transformed the management of aortic aneurysms and dissections through its minimally invasive approach and favorable short-term outcomes. However, concerns regarding the long-term cardiovascular implications of endograft implantation have …

    milano Repository record for AORTIC STIFFNESS MODIFICATIONS AFTER ENDOVASCULAR AORTIC REPAIR (opens in a new tab) Embargoed

  2. Percutaneous Aortic Valve ReplacementThe Anatomy of Aortic Root Structures and Postmortem Aortic Valve Stent Implantation

    … close proximity of the coronary orifice to the aortic valve leaflets made percutaneous and transapical aortic valve implantation a major challenge such as coronary flow impairment. In this study, the aortic root structures were observed and measured in human cadavers. Material and Methods: We …

    cau-kiel Repository record for Percutaneous Aortic Valve ReplacementThe Anatomy of Aortic Root Structures and Postmortem Aortic Valve Stent Implantation (opens in a new tab)

  3. Granzyme B in abdominal aortic aneurysm and aortic dissection

    … angiotensin II (angli) infusion. To induce aortic dissections, 3-month-old C57 (wildtype), apoE-KO, and GrB/apoE-DKO mice were implanted with an osmotic mini pump which released a dose of 1000ng/kg/min of angli (or saline as a control) for 28 days. The mice were euthanized at 28 days, and …

    ubc Repository record for Granzyme B in abdominal aortic aneurysm and aortic dissection (opens in a new tab) Download PDF for Granzyme B in abdominal aortic aneurysm and aortic dissection (opens in a new tab)

  4. Aortic Tissue-Stent Mechanical Interaction in Transcatheter Aortic Valve Replacement

    … has been an explosive growth in transcatheter aortic valve replacement (TAVR). By the end of 2011, about 70,000 TAVRs have been performed worldwide. Short- and medium-term outcomes after TAVR are encouraging with significant reduction in rates of death. However, adverse events associated with …

    uconn-diss Repository record for Aortic Tissue-Stent Mechanical Interaction in Transcatheter Aortic Valve Replacement (opens in a new tab)

  5. Biomechanics of transcatheter aortic valve replacement for bicuspid aortic valves

    Bicuspid aortic valve (BAV) is the most common congenital heart defect and is associated with numerous pathologies including calcific aortic valve disease (CAVD) which requires replacement of the native valve. Replacements are delivered through either surgical or transcatheter aortic valve …

    gatech Repository record for Biomechanics of transcatheter aortic valve replacement for bicuspid aortic valves (opens in a new tab)

  6. Thoracoabdominal aortic aneurysm life-threatening events following endovascular aortic repair

    … and mortality related to endovascular abdominal aortic aneurysm repair (EVAR), complex EVAR, and thoracic endovascular aortic repair (TEVAR), as well as the details of these procedures in order to mitigate the risks in the future. We characterized the odds of adverse outcomes and complications …

    bu Repository record for Thoracoabdominal aortic aneurysm life-threatening events following endovascular aortic repair (opens in a new tab)

  7. Computer Aided Diagnostics and Intervention Planning in the Aortic Valve: An Application on Aortic Stenosis and Transcatheter Aortic Valve Replacement

    Aortic stenosis (AS) is a critical valvular disease often treated by Transcatheter Aortic Valve Replacement (TAVR). This thesis introduces several novel approaches for improving the assessment and management of AS and the associated TAVR procedure. The research presents new indices for …

    mcmaster Repository record for Computer Aided Diagnostics and Intervention Planning in the Aortic Valve: An Application on Aortic Stenosis and Transcatheter Aortic Valve Replacement (opens in a new tab)

  8. Restoration of supra-aortic vessel perfusion after open hybrid stenting of the aortic arch for acute type A aortic dissection

    Objectives: Acute type A aortic dissection is a lethal condition that requires emergent surgical repair, especially in case of cerebral malperfusion. In this setting, we aimed to investigate perfusion patterns in the aorta and in the supra-aortic vessels after implantation of the Ascyrus Medical …

    fu-berlin Repository record for Restoration of supra-aortic vessel perfusion after open hybrid stenting of the aortic arch for acute type A aortic dissection (opens in a new tab)

  9. A novel method for determining aortic stiffness : the hemodynamic aortic stiffness method

    … on their Cardiovascular Risk (CR) assessment. Aortic stiffness is known to help predict the likelihood of a cardiac event, making it an important CR factor. The current "gold-standard" method for measuring aortic stiffness is the carotid-femoral pulse wave velocity (cfPWV) analysis method. …

    missouri Repository record for A novel method for determining aortic stiffness : the hemodynamic aortic stiffness method (opens in a new tab)

  10. Analysis of Particles Thorough the Aortic Arch During Transcatheter Aortic Valve Replacement

    … becoming dislodged during transcatheter aortic valve replacement (TAVR) is a possible complication of TAVR. The particles that become dislodged can travel out of the aortic valve, into the aortic arch, and then into either the brachiocephalic artery, the left common carotid artery, the …

    calpoly Repository record for Analysis of Particles Thorough the Aortic Arch During Transcatheter Aortic Valve Replacement (opens in a new tab)

  11. Sutureless Aortic Valve Replacement

    Aortic Stenosis (AS) is the most common valvular heart disease. Aortic valve replacement (AVR) is the only acceptable treatment for AS. Several replacement methods are available to treat AS including conventional surgical aortic valve replacement (SAVR), transcatheter aortic valve replacement …

    mcmaster Repository record for Sutureless Aortic Valve Replacement (opens in a new tab)

  12. Stiffness of mouse aortic elastin and its possible relation to aortic media structure

    Aortic elastin allows arterial expansion on systole and subsequent elastic recoil during diastole, providing crucial capacitance and associated dampening of the cardiac pressure pulses. The structure and mechanical properties of the aortic wall are not uniform along its length due to the varying …

    ubc Repository record for Stiffness of mouse aortic elastin and its possible relation to aortic media structure (opens in a new tab) Download PDF for Stiffness of mouse aortic elastin and its possible relation to aortic media structure (opens in a new tab)

  13. Improving Preadmission Testing Nurses' Knowledge of Aortic Stenosis and Transcatheter Aortic Valve Replacement

    … (PAT) nurses’ knowledge of severe/critical aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) procedure and patient selection, and satisfaction with knowledge by 10%. Rapid growth of the TAVR program has contributed to a gap in nursing knowledge leading to inconsistent …

    usfca Repository record for Improving Preadmission Testing Nurses' Knowledge of Aortic Stenosis and Transcatheter Aortic Valve Replacement (opens in a new tab)

  14. Discovering the link between bicuspid aortic valve and aortic aneurysms: genetic or hemodynamic?

    OBJECTIVES: The association between bicuspid aortic valves and aortic aneurysms has been well documented. In order to better understand this association, this study sought to accomplish two goals. The first was to determine if there was any correlation between specific bicuspid aortic valve …

    bu Repository record for Discovering the link between bicuspid aortic valve and aortic aneurysms: genetic or hemodynamic? (opens in a new tab)

Page 1 of 151