Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 613 for “"Aortic Valve"”.
-
Sutureless Aortic Valve Replacement
Aortic Stenosis (AS) is the most common valvular heart disease. Aortic valve replacement (AVR) is the only acceptable treatment for AS. Several replacement methods are available to treat AS including conventional surgical aortic valve replacement (SAVR), transcatheter aortic valve replacement …
-
Comparison of patient outcome for aortic valve replacement verses transcatheter aortic valve replacement
Aortic stenosis or narrowing of the aortic valve is the most common cause for surgical valvular replacement in the United States. The disease of aortic stenosis has a long asymptomatic latency period followed by a quickly progressing symptomatic phase. Symptoms of the disease include dyspnea, …
-
Aortic valve mechanobiology- role of altered hemodynamics in mediating aortic valve inflammation and calcification
Calcific aortic valve (AV) disease is a strong risk factor for cardiovascular related deaths and is a significant source of mortality worldwide, with the number of patients requiring AV surgery expected to increase from 250,000 to 850,000 by 2050. However, the molecular mechanisms underlying AV …
-
Hemodynamics of aortic valve stenoses
The aortic valve of a human heart is located between the left ventricle and the aorta. Its function is to open during the systole, allowing the blood to flow to the aorta in order to feed the organs and close during the diastole, preventing blood flow back into the left ventricle. Disease can lead …
-
Introducing transapical aortic valve implantation
… from the field of transapical transcatheter aortic valve implantation, when incorporated into a structured training and then gradually dispersed by internal proctoring, might eliminate the negative effect of the learning curve on the clinical outcomes. Methodology: The present study was a …
-
Percutaneous Aortic Valve ReplacementThe Anatomy of Aortic Root Structures and Postmortem Aortic Valve Stent Implantation
… close proximity of the coronary orifice to the aortic valve leaflets made percutaneous and transapical aortic valve implantation a major challenge such as coronary flow impairment. In this study, the aortic root structures were observed and measured in human cadavers. Material and Methods: We …
-
Low flow low gradient aortic valve stenosis: the role of transcatheter aortic valve replacement (TAVR)
… on comparative long-term outcomes of severe aortic stenosis (AS) patients with different flow-gradient patterns undergoing transcatheter aortic valve replacement (TAVR). This study sought to evaluate the impact of pre-TAVR flow-gradient pattern on long-term clinical outcomes after TAVR and …
-
Understanding the pathophysiology of aortic valve dysfunction using advantage CMR techniques: 4D flow in aortic valve disease
<p>Aortic valve disease is common with early valve thickening (known as aortic sclerosis, ASC) affecting around 30% of those over 65 years of age, and nearly 3% of the population over 75 years old having haemodynamically significant aortic stenosis. During clinical follow up of aortic stenosis, …
-
Non-invasive examination of the vascular adaption in patients with aortic valve stenosis after transcatheter aortic valve implantation
Aortic stenosis (AS) is the most common acquired valvular heart disease in high-income countries. It has an estimated prevalence of 4% in the age group of 70 years and older. Many studies predict that this will increase in the next decades due to an ageing population and improved diagnostic …
-
Computed tomography aortic valve calcium scoring and its association with adverse events following transcatheter aortic valve implantation (TAVI)
Background: Severe aortic valve calcification (AVC) has generally been recognized as a key factor in the occurrence of adverse events after transcatheter aortic valve implantation (TAVI). To date, however, a consensus on a standardized calcium detection threshold for aortic valve calcium …
-
Leaflet Material Selection for Aortic Valve Repair
Leaflet replacement in aortic valve repair (AVr) is associated with increased long-term repair failure. Hemodynamic performance and mechanical stress levels were investigated after porcine AVr with 5 types of clinically relevant replacement materials to ascertain which material(s) would be best …
-
Waiting time and predictors of waiting time for transcatheter aortic valve implantation in patients with severe aortic valve stenosis /
… Even though the global numbers of transcatheter aortic valve implantation (TAVI) increase yearly, the ageing population and expanding indications create the demand for TAVI, which is still unmet. Patients with diagnosed symptomatic severe aortic valve stenosis have a poor prognosis and increased …
-
Severe aortic valve stenosis and the consequences of transcatheter and surgical aortic valve replacement: A cardiovascular magnetic resonance study.
Background: Severe symptomatic aortic stenosis (AS) heralds a poor prognostic outlook and significant co-morbidity, with valve replacement the only definitive cure. Transcatheter aortic valve implantation (TAVI) has developed as an alternative to the standard treatment of surgical aortic valve …
-
Computer Aided Diagnostics and Intervention Planning in the Aortic Valve: An Application on Aortic Stenosis and Transcatheter Aortic Valve Replacement
Aortic stenosis (AS) is a critical valvular disease often treated by Transcatheter Aortic Valve Replacement (TAVR). This thesis introduces several novel approaches for improving the assessment and management of AS and the associated TAVR procedure. The research presents new indices for …
-
Mechanical Studies on the Porcine Aortic Valve Part II: A Stress Analysis of the Porcine Aortic Valve Leaflets in Diastole
<p> A stress analysis of porcine aortic valve leaflets in diastole at 80 mm. Hg. in-vitro is presented. Incorporations of local surface geometry, leaflet material inhomogeneity, anisotropy and non-linearity are applied. The stress theory used is a modified form of the thin membrane stress theory …
-
Mechanical Studies on the Porcine Aortic Valve Part I: Geometrical Asymmetry, Material Inhomogeneity and Anisotropy in the Porcine Aortic Valve
… of studies on the natural and the prosthetic aortic valves are reviewed. </p> <p> A microtensile technique devised to investigate the inhomogeneous and anisotropic material properties of a porcine aortic valve's leaflets is described. Also, the theory and apparatus of a new …
-
Mechanisms of fibrosis-meditated bioprosthetic aortic valve dysfunction
The full abstract for this thesis is available in the body of the thesis, and will be available when the embargo expires.
-
Hydrodynamic performance of an artificial aortic valve implant
… aims at studying fluid dynamics of a prosthetic aortic heart valve through an organized experimental programme with a view to obtain better appreciation of factors affecting its performance and eventual failure. The problem is approached in stages representing an increasing order of difficulties …
Page 1 of 31