Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Aortic Valve Insufficiency"”

  1. Es el reimplante valvular mejor que el bentall biológico modificado para tratar aneurismas de la raíz asociados a insuficiencia?

    … after modified Bentall procedure with Freestyle valve vs. Valvular Reimplantation Tirone David, for the aortic valve insufficiency secondary to aortic root aneurysm. DESIGN: Revision of institutional registers of 88 patients treated from January 2003 to august 2009 with aortic insufficiency …

    rosario Repository record for Es el reimplante valvular mejor que el bentall biológico modificado para tratar aneurismas de la raíz asociados a insuficiencia? (opens in a new tab)

  2. Valvular Heart Disease in Community-Dwelling Older Adults: Risk Factors, Adverse Outcomes, and Potential Biomarkers

    … assessed by LA reservoir strain, and mitral valve regurgitation (MR). Reduced LA function was associated with both prevalent and incident MR, suggesting that atrial dysfunction may precede the development of MR. The second manuscript evaluated the association between aortic valve stenosis …

    umn Repository record for Valvular Heart Disease in Community-Dwelling Older Adults: Risk Factors, Adverse Outcomes, and Potential Biomarkers (opens in a new tab)

  3. RPM and flow modulation for a continuous flow left ventricular assist device to increase vascular pulsatility : a computer simulation, mock circulation, and in-vivo animal study.

    … events including gastrointestinal bleeding, aortic valve insufficiency, and hemorrhagic strokes. To overcome these limitations, we have developed flow/RPM modulation algorithms to provide vascular pulsatility using a CF LVAD. Methods: The effects of timing and synchronizing the CF LVAD …

    louisville Repository record for RPM and flow modulation for a continuous flow left ventricular assist device to increase vascular pulsatility : a computer simulation, mock circulation, and in-vivo animal study. (opens in a new tab)

  4. Germline ERG Haploinsufficiency in Predisposition to Disease

    … dysfunction (primarily manifesting as aortic aneurysms and/or aortic valve insufficiency). Following publication, ERG has now been included on high evidence germline targeted sequencing panels for BMF and HM predisposition, including at PanelApp Australia, SA Pathology (Department of …

    adelaide Repository record for Germline ERG Haploinsufficiency in Predisposition to Disease (opens in a new tab)

  5. Shear layer instabilities and flow-acoustic coupling in valves: application to power plant components and cardiovascular devices

    … axisymmetric cavity, associated with inline gate valves, was investigated. In many engineering applications, such as flows through open gate valves, there exists potential for coupling between the vortex shedding from the up-stream edge of the cavity and a diametral mode of the acoustic pressure …

    uvic Repository record for Shear layer instabilities and flow-acoustic coupling in valves: application to power plant components and cardiovascular devices (opens in a new tab)

  6. A sequential evaluation of left ventricular function in asymptomatic and symptomatic patients with chronic severe aortic regurgitation

    The optimal timing of valve replacement surgery in chronic severe aortic regurgitation (AR) has remained a major clinical problem in the management of these patients. Although the onset of symptoms is the generally accepted indication for aortic valve replacement (AVR), the unpredictable …

    cape-town Repository record for A sequential evaluation of left ventricular function in asymptomatic and symptomatic patients with chronic severe aortic regurgitation (opens in a new tab)

  7. Reproducibility of a continuous-wave Doppler ultrasound system for assessment of ascending aortic blood flow responses during graded exercise testing with healthy individuals

    … (CW) Doppler recordings of ascending aortic maximal blood flow acceleration (PkA), maximal velocity (PkV) and systolic velocity integral (SVI) were taken at each stage of a graded exercise treadmill test on two separate days with 30 physically active adult males. Signals were measured …

    vt Repository record for Reproducibility of a continuous-wave Doppler ultrasound system for assessment of ascending aortic blood flow responses during graded exercise testing with healthy individuals (opens in a new tab)

  8. Κλινικά, επιδημιολογικά και ανοσογενετικά δεδομένα της αρτηριίτιδας Takayasu στην Ελλάδα

    … disease occurred in 12% and mild to median aortic valve insufficiency in 1/3 of the patients. Angiographically, the most frequent lesion was stenosis (95%), followed by aneurysm (40%) and occlusion (35%). Most patients (70%) had extensive disease, with lesions above and below diaphragm. …

    greece Repository record for Κλινικά, επιδημιολογικά και ανοσογενετικά δεδομένα της αρτηριίτιδας Takayasu στην Ελλάδα (opens in a new tab)

  9. Aortic strain in bicuspid aortic valve: an analysis

    Introduction: Bicuspid aortic valve (BAV) is frequently related to aortic valve disease and aortopathy and it is usually monitored by transthoracic echocardiography and CT angiography. However, early markers of disease progression are not available at the moment. Speckle-tracking echocardiography …

    coimbro Repository record for Aortic strain in bicuspid aortic valve: an analysis (opens in a new tab)

  10. The aorta in transposition of the great arteries

    … results on the prevalence and evolution of neo-aortic root pathology and surgical cardiovascular outcomes in patients after arterial switch operation (ASO) for transposition of the great arteries. Furthermore, thoracic aortic blood flow hemodynamics were investigated in relation to post-ASO …

    leiden Repository record for The aorta in transposition of the great arteries (opens in a new tab)

  11. The fluid shear stress environment of the normal and congenital bicuspid aortic valve and the implications on valve calcification

    Calcific aortic valve disease is highly prevalent, especially in the elderly. Currently, the exact mechanism of the calcification process is not completely understood, limiting our ability to prevent or cure the disease. Ex vivo investigations, however, have provided evidence that the aortic …

    gatech Repository record for The fluid shear stress environment of the normal and congenital bicuspid aortic valve and the implications on valve calcification (opens in a new tab)