Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 44 for “"Aqueous sample"”.
-
Solid Phase Microextraction in Aqueous Sample Analysis
… analytical methods developed for complex aqueous sample analysis based on solid phase microextraction (SPME). First, the laboratory evaluation of the kinetic calibration approach in aqueous sample analysis using SPME is discussed. A modified SPME device, Polydimethylsiloxane (PDMS) rod …
-
Aqueous Sample Preparation for Improved In Situ Biosignature Detection at Ocean Worlds
… detection. With increasing calls for aqueous sample processing capabilities, astrobiologists must now decide which biomarkers to target, and how to best detect them. Finding potential indicators of life like amino acids, proteins, and long chain polymers on another planet or moon would …
-
Raman Spectroscopy for Monitoring of Microcystins in Water
… cyanotoxin variants potentially present in an aqueous sample. The use of Raman spectroscopy for identification and quantification of the ubiquitous cyanotoxin microcystin-LR (MC-LR) was examined. Raman spectra readily reflect minute changes in molecular structure, spectra can be collected …
-
Liquid-liquid extraction of chromium by diphenyl-2-pyridylmethane
<p>The liquid-liquid extraction of chromium from aqueous solutions of hydrochloric acid by diphenyl-2-pyridylmethane (DPPM) dissolved in hydrogen-bonding organic diluents has made possible the separation, concentration and speciation of chromium at trace concentrations. In the extraction of Cr(VI) …
-
A Deuterium Labeling Method for the Characterization of (Chromophoric) Dissolved Organic Matter Using Ultrahigh Resolution Electrospray Ionization Mass Spectrometry
… emission of chromophoric DOM. In this method, an aqueous sample is treated with sodium borodeuteride (NaBD4) and is analyzed via ultrahigh resolution electrospray ionization (ESI) mass spectrometry. Ketone/aldehyde-containing species (at mass m) in the untreated sample are identified by searching …
-
Development of Environmentally Friendly Dispersive Liquid-Liquid Microextraction Techniques
… dispersion of low-density organic solvent to the aqueous sample in an even faster and more efficient way, low-density solvent-based vortex-assisted surfactant-enhanced DLLME has been investigated. The results presented in this thesis show that all the DLLME techniques could serve as excellent …
-
Ανάπτυξη, βελτιστοποίηση και επικύρωση υγρής-υγρής μικροεκχύλισης και μεθοδολογίας αέριας χρωματογραφίας συζευγμένης με φασματομετρία μάζας για τον προσδιορισμό πολυκυκλικών αρωματικών υδρογονανθράκων με τη χρήση χημειομετρικών μεθόδων σε υδατικά δείγματα: εκτίμηση οικοτοξικολογικού κινδύνου για την λεκάνη απορροής του ποταμού Άραχθου
… for the determination of PAHs in natural water samples, for the first time, followed by gas chromatography–mass spectrometry(GC/MS). The second is to evaluate and optimize the method with the aid of response surface methodology and experimental design. And finally the third is to calculate the …
-
Aqueous phase behaviour of surfactant and its application in cloud-point extraction
… developed to extract trace amount of HOCs from aqueous sample. CPE experiment was conducted at room temperature (22A?C) by adding small amount of salt to micellar solution. Recoveries efficiencies were found ranging from 72% to 103%. The effect of the molecular structures and the HLB values of …
-
Microfabrication of Bio-Analytical Devices: Microelectrode Array and Traveling-Wave Electrophoresis
… the portability and speed of detection for aqueous samples. Photolithography techniques serve as a cost effective fabrication tool to create LOC electrodes on the micron scale. An in-depth look at the fabrication process is undertaken in this paper in order to further the development of …
-
Development of multi-residue and selective methods for the ultra-sensitive determination of endocrine disrupting chemicals in aqueous samples
… environmental matrix is very complex. Therefore, sample clean-up en pre-concentration of the sample is necessary before analysis. In this framework, the current work focuses on the optimization of the sample preparation in order to develop selective and multi-residue methods for the determination …
-
Investigation of a new microchip electrophoresis instrument for semi-continuous aerosol composition measurements
… and one organic acid (oxalate) in the collected aqueous sample is achieved using microchip capillary electrophoresis coupled with conductivity detection. The ACE system was tested in multiple pilot field studies and compared with measurements collected by a particle-into-liquid sampler coupled …
-
Analysis of iodide and iodate in soil and water
… to the analysis of environmental water and soil samples. Two different approaches based on GC/MS were developed and tested; The first approach is based on adsorption of the iodide in an aqueous sample by anion exchange resin. The resin is then analyzed by pyrolysis-GC/MS. Pyrolysis of the resin …
-
Biodegradation of phenanthrene in freshwater environments
… hydrocarbon (PAH), was incubated with water samples from various reservoir systems in Tennessee to evaluate the potential for significant PAH degradation by the indigenous microbial populations. Biodegradation was measured by comparison of total PAH substrate recovery in degradation flasks …
-
Chloro organinių pesticidų ekstrakcijos metodų tyrimas /
… preconcentration of organic compounds from water samples. In this method, the appropriate mixture of extraction solvent and disperser solvent are injected into the aqueous sample by syringe, rapidly. Therefore, cloudy solution is formed. After centrifuging, the extraction solvent with the analytes …
-
Determination of Mercury (II) and Nitrate Concentrations in Natural Waters Using Ion-Selective Electrodes and Atomic Emission Spectroscopy
… ions to enter the organic membrane from the aqueous sample solution. The voltage difference created as a result of this transfer process can be correlated directly to ion concentration. The first part of this research project will be to determine with ionophore is most selective for each ion …
-
Qualitative and quantitative analysis of Beta emitters in aqueous solutions
… and measuring beta activity in low level aqueous environmental solution as well as identifying the radioisotopes present.Aqueous solutions of standard beta emitters, covering a range of energies between 18.6 KeV and 3550 KeV, were used to develop computer methods for analysis.The best …
-
Studies of Sample Compartmentalization By Microfluidic Methods
… is novel for its simplicity. In this method an aqueous sample is compartmentalized into smaller droplets by an immiscible phase and stored on-site. Self-digitization does not require complex microfluidic design or complex pumping and valving technologies to generate droplets. The volume of these …
-
Development and Application of Integrated Silicon-in-Plastic Microfabrication in Polymer Microfluidic Systems
… The chemical monitoring system is designed to sample a water source, extract solvent present within the aqueous sample into the vapor phase, and direct the solvent vapor past the integrated gas sensor for analysis. Design, fabrication, and characterization of a prototype system are described, …
-
Rapid sample preparation methods for use with high -speed gas chromatography.
Rapid sample preparation schemes for analysis of high humidity gas and aqueous samples by high speed gas chromatography (HSGC) are described in this dissertation. Sample preparation methods are known to be a limiting factor in HSGC analysis. Most notably, cryointegrating HSGC instruments have been …
-
Comparação entre metodologias de extração de HPAs em água utilizando um planejamento fatorial com quantificação no CG/EM
… finally apply the results in chemometrics. The sample was synthesized and subjected to tests of the 23 factorial design, which has the factors: the type of extraction technique (ultrasound and digester), the ratio solvent / sample (1:1 and 1:3) and the type of solvent (dichloromethane / hexane …
Page 1 of 3