Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Arc flash"”.

  1. ARC FLASH IN SINGLE-PHASE ELECTRICAL SYSTEMS

    <p>Arc flash and blast are hazards unique to electrical installations. Such events can start fires, destroy equipment, and severely injure or kill workers. NFPA 70E and IEEE 1584 are defining standards for arc flash hazard analysis used during system design, construction, and maintenance. Both …

    utk-theses Repository record for ARC FLASH IN SINGLE-PHASE ELECTRICAL SYSTEMS (opens in a new tab)

  2. ARC FLASH DETECTION THROUGH VOLTAGE/CURRENT SIGNATURES

    Arc Flash events occur due to faults in electrical equipment combined with a significant release of energy across an electrical arc. Due to the large energy release, plasma is generated, pressures increase, and the plasma expands. Under these conditions the plasma becomes excited enough to liquefy …

    sask Repository record for ARC FLASH DETECTION THROUGH VOLTAGE/CURRENT SIGNATURES (opens in a new tab)

  3. Arc-flash analysis of utility power systems

    … potential hazards daily. One such hazard is an arc flash. An arc flash is a rapid release of energy, referred to as incident energy, caused by an electric arc. Due to the random nature and occurrence of an arc flash, one can only prepare and minimize the extent of harm to themself, other …

    mtu Repository record for Arc-flash analysis of utility power systems (opens in a new tab)

  4. Managing Arc Flash Hazard in Power Distribution Systems

    Arc Flash can lead to fatality or destruction. So a thorough understanding of this phenomenon will complement safety and mitigation efforts. For minimizing the exposure of an Arc Flash to the worker, personal protective equipment should be used depending on the incident energy level for the task. …

    ttu Repository record for Managing Arc Flash Hazard in Power Distribution Systems (opens in a new tab)

  5. Development of the Impedance-based Arc-Flash Determination Device (IADD)

    … entitled, 'Development of the Impedance based Arc-Fault Determination Device (IADD)' details the development of a testing device that, when attached to an electrical node on the power system and through observations on voltage, current and phase shift with a step load change, determines the …

    clemson Repository record for Development of the Impedance-based Arc-Flash Determination Device (IADD) (opens in a new tab)

  6. Approaches to Arc Flash Hazard Mitigation in 600 Volt Power Systems

    Federal regulations have recognized that arc flash hazards are a critical source of potential injury. As a consequence, in order to work on some electrical equipment, the energy source must be completely shut-down. However, power distribution systems in mission critical facilities such as hospitals …

    usf Repository record for Approaches to Arc Flash Hazard Mitigation in 600 Volt Power Systems (opens in a new tab)

  7. Creating a Comparative Map of Relative Power for DC ARC Flash Methodologies

    Although arc flash has been a concern amongst the electrical industry for many years, it is only relatively recently that standards by the IEEE have been established on calculating the amount of energy behind an arc flash event. However, these standards only apply to AC systems, where extensive …

    calpoly Repository record for Creating a Comparative Map of Relative Power for DC ARC Flash Methodologies (opens in a new tab)

  8. Methods for Arc-Flash Prediction in Medium Voltage and Low Voltage Switchgear

    … are unbearable by the modern society. Arc-flash is the unintentional discharge of electricity through air which produces very high temperature (19,600 ºC), which is hotter than the surface of the sun and a force equivalent to being hit by a hand grenade. Occurrence of an arc-flash in …

    aalto Repository record for Methods for Arc-Flash Prediction in Medium Voltage and Low Voltage Switchgear (opens in a new tab)

  9. Arc Flash Mitigation: Overview of Codependent System Studies Relevant to IEEE Standard 1584

    Accidents due to arc flash events are currently of special interest in the electrical power industry. These events often result in serious injuries, deaths, equipment damage, facility shutdowns, lawsuits, and penalties. Risk assessments are usually performed by the power systems engineer during the …

    houston Repository record for Arc Flash Mitigation: Overview of Codependent System Studies Relevant to IEEE Standard 1584 (opens in a new tab)

  10. Energia incidente para determinação de categoria de equipamentos de proteção individual na manutenção de subestação abrigada de 2000 kVA: estudo de caso na nova Sede do Estudo de TJRN

    … exposes workers to the risk of electric arc flash, a phenomenon characterized by the intense release of thermal energy capable of causing severe burns within fractions of a second. Routine interventions such as thermographic inspections, electrical measurements and switching operations in …

    brazil-ufrn Repository record for Energia incidente para determinação de categoria de equipamentos de proteção individual na manutenção de subestação abrigada de 2000 kVA: estudo de caso na nova Sede do Estudo de TJRN (opens in a new tab)

  11. The initiation of electric arcs and the possible impact in industrial environments

    … knowledge and understanding of electrical arc flash and arc blast hazards through experimentation, modelling and analysis is the main goal of the present thesis. To achieve this, initially, significant work has been carried out to analyse existing data on arc flash hazards and mitigation …

    strathclyde Repository record for The initiation of electric arcs and the possible impact in industrial environments (opens in a new tab)

  12. The initiation of electric arcs and the possible impact in industrial environments

    … knowledge and understanding of electrical arc flash and arc blast hazards through experimentation, modelling and analysis is the main goal of the present thesis. To achieve this, initially, significant work has been carried out to analyse existing data on arc flash hazards and mitigation …

    greece Repository record for The initiation of electric arcs and the possible impact in industrial environments (opens in a new tab)

  13. Practical knowledge in electrical engineering : applying lessons from industry to the classroom.

    … conduit routing, how to read and create a P&ID, arc flash calculations, and area classification. With regards to conductor sizing, the importance of specifying the correct size of conductor, the standard sizes of conductors, the types of conductor insulation, and finally detail the calculations …

    louisville Repository record for Practical knowledge in electrical engineering : applying lessons from industry to the classroom. (opens in a new tab)

  14. Mitigating risks associated with Lockout/Tagout (LOTO) of hazardous energy in Nigeria : a tracker approach

    … electrical personnel experience, electrocution, arc flash, arc blast, burns and lockout and tagout of the wrong electrical circuit are seen as the biggest electrical safety risk with regards to LOTO of hazardous energy. The research reveals new information about electrical accident risks. This …

    nwu-za Repository record for Mitigating risks associated with Lockout/Tagout (LOTO) of hazardous energy in Nigeria : a tracker approach (opens in a new tab)

  15. Low-Cost Melt Pool Monitoring in Wire Arc Additive Manufacturing

    <p>Wire-Arc Additive Manufacturing (WAAM) is an emerging metal manufacturing technology that utilizes welding processes to build large-scale components in significantly reduced timeframes at lower costs with less material waste. However, maintaining consistent part quality remains a challenge due …

    ut-knoxville Repository record for Low-Cost Melt Pool Monitoring in Wire Arc Additive Manufacturing (opens in a new tab)

  16. Arc Fault Detection in DC Photovoltaic Systems

    Arc faults have always been a concern for electrical systems as they can cause fires, personnel shock hazard, and system failure. In photovoltaic (PV) systems, a large number of electrical connectors and long wire runs are expected. Combined with the high DC voltage, deterioration of the wire …

    tamu Repository record for Arc Fault Detection in DC Photovoltaic Systems (opens in a new tab)

  17. Zjednodušený model axiálně chlazeného oblouku

    Výhodami využití výpočetní techniky je rychlé a přehledné zpracování dat. Nabízí se i velká variabilita a okamžitá možnost změny přenášené informace, stejně jako jejich časté nebo opakované používání. Od různorodosti a velikosti přenášených informací se odvíjí použité technologie a kapacita …

    brno-tech Repository record for Zjednodušený model axiálně chlazeného oblouku (opens in a new tab)