Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Arc quenching"”

  1. Investigation of the stability of short arcs

    The research described in this thesis is an investigation of stability of short arcs. It is on fault tolerant medium voltage distribution networks. It serves to describe experimental findings of the investigation of stability of short (1000mm) arcs. The instability of short arcs with high source …

    cape-town Repository record for Investigation of the stability of short arcs (opens in a new tab)

  2. CFD Analysis and Molecular Kinetics in a Supercritical CO2 Circuit Breaker

    … high pressures is investigated in regards to its arc quenching capabilities to suppress reignition in high-voltage circuit breakers. scCO2 is a favorable replacement for the current SF6 gas, which produces toxic byproducts. SF6 contributes heavily to the global warming crisis, and it is paramount …

    gatech Repository record for CFD Analysis and Molecular Kinetics in a Supercritical CO2 Circuit Breaker (opens in a new tab)

  3. Suppression of electrical discharges

    … exclusively used as a dielectric insulator and arc quenching medium in high voltage power networks. The electronegative properties of the gas and its ability to recombine after dissociation make it a gas of choice for high voltage equipment. However, SF 6 is a greenhouse gas and therefore …

    liverpool Repository record for Suppression of electrical discharges (opens in a new tab)

  4. DC interruption principle using a helical arc arrangement

    … currents. Much work has investigated the use of arc discharges for interrupting DC current. The problem with DC current is that there is no natural current zero where thermal losses from the arc dominate thus leading to arc extinction and the interruption of fault current. Helical arc been …

    liverpool Repository record for DC interruption principle using a helical arc arrangement (opens in a new tab)

  5. Method and Realization of Parallel Computing for Switching Arc Simulation Based on a Mix of Structured and Unstructured Grids

    … (SF6) has long been the preferred insulating and arc-quenching medium due to its excellent dielectric properties and arc cooling ability in HVCBs. However, SF6 is a potent greenhouse gas with a global warming potential more than 25,200 times that of CO2, creating an urgent need for eco-friendly …

    liverpool Repository record for Method and Realization of Parallel Computing for Switching Arc Simulation Based on a Mix of Structured and Unstructured Grids (opens in a new tab) Embargoed until 2028-08-01

  6. A study of the influence of an external magnetic field on electric arc behaviour in low-voltage dc switching

    … measures are required to extinguish the electric arc formed when the contacts separate.<br/><br/>In many low-voltage devices, arcs are extinguished by driving the arc into splitter plates using the self-induced magnetic field. The splitter plates divide the arc into multiple segments, rapidly …

    soton Repository record for A study of the influence of an external magnetic field on electric arc behaviour in low-voltage dc switching (opens in a new tab)

  7. Comportement d'un arc électrique impulsionnel de forte intensité : cas du disjoncteur modulaire

    … contre les défauts de court-circuit. L’arc électrique, généré dans la chambre de coupure du disjoncteur lors de l’ouverture du circuit, est fractionné en plusieurs arcs dans un assemblage de multiples plaquettes métalliques, afin de limiter l’intensité du courant et d'isoler le défaut. …

    star-france Repository record for Comportement d'un arc électrique impulsionnel de forte intensité : cas du disjoncteur modulaire (opens in a new tab)

  8. Detection of low residual current flow through gas during the arcing period

    … are extensively utilized as excellent methods of arc quenching. To optimize the efficiency and effectiveness of switchgear performance in interruption of the fault current through extinguishing the arc as well as to withstand the rate of rise of recovery voltage (rrrv) after current zero, the …

    liverpool Repository record for Detection of low residual current flow through gas during the arcing period (opens in a new tab)

  9. Operation and protection of DC shipboard power system

    … current crossing which worsens the problem of arc quenching. In dc power system, the converters will be used as interfaces between the generators and the marine loads. During the fault, the dc-link capacitor will discharge rapidly, releasing high current. This capacitive discharge current …

    nanyang Repository record for Operation and protection of DC shipboard power system (opens in a new tab)

  10. Investigation of the dynamic characteristics and decaying behaviour of SF6 Arcs in switching applications

    … characteristics and decaying behaviour of SF6 arcs during the current-zero period is of great significance to improving the interruption performance of high voltage circuit breakers and ensuring their reliable operation. The present research was conducted by means of modeling and experiment to …

    liverpool Repository record for Investigation of the dynamic characteristics and decaying behaviour of SF6 Arcs in switching applications (opens in a new tab)

  11. Modelling and Simulation of Air and SF6 Switching Arcs in High Voltage Circuit Breakers

    … is concerned with the modelling of switching arcs in air in high voltage circuit breakers and with a comparative study of interruption capability of air and SF6 switching arcs. Emphasis is given to the identification of dominant energy transport processes for arc interruption and the material …

    liverpool Repository record for Modelling and Simulation of Air and SF6 Switching Arcs in High Voltage Circuit Breakers (opens in a new tab)

  12. Computer simulation of fundamental processes in high voltage circuit breakers based on an automated modelling platform

    Auto-expansion circuit breakers utilize the arc’s energy to generate the flow conditions required for current interruption. The operation of this type of circuit breaker is extremely complex and its interruption capability depends on the whole arcing history as well as a number of geometric …

    liverpool Repository record for Computer simulation of fundamental processes in high voltage circuit breakers based on an automated modelling platform (opens in a new tab)