ArcCheck Phantom with Tissue Equivalent Inserts for Validation of Treatment PlanningSystem Dose Calculation in Heterogenous Media
… curves obtained in auniform medium of the water phantom.Verification of the dose calculation algorithm accuracy in heterogeneous mediumis a required part of the treatment planning system (TPS) commissioning process. Apartfrom validation of the dose calculation algorithm, it is also a test of the …
-
CLINICAL VALIDATION OF DELIVERY ANALYSIS SOFTWARE FOR PATIENT-SPECIFIC QUALITY ASSURANCE OF RADIXACT (TOMOTHERAPY) TREATMENT
… PSQA plans executed on a Radixact machine using ArcCheck phantom and delivery analysis (DA) software. The %GP was calculated using a 3% dose difference (DD), a 2 mm distance-to-agreement (DTA), and a 10% threshold. A passing criterion of ≥95% was applied for PSQA evaluation. The %GP was analyzed …
-
Evaluation of a Helical Diode Array and Planned Dose Perturbation Model for Pretreatment Verification of Volumetric Modulated Arc Therapy
The ArcCHECK dosimeter is a novel dosimetry tool that uses a helical array of silicon diode detectors to measure dose in a cylindrical plane. 3DVH is an associated software that can use ArcCHECK diode measurements along with treatment planning system (TPS) data to guide a full 3D dose …
-
Optimizing Of Spoiler Thickness For Total Body Irradiation (TBI) Utilizing Tomotherapy Technology
… from the EBT3 films that were mounted on the ArcCHECK phantom and irradiated with the Tomotherapy machine. The ion chamber measurements within the ArcCHECK system demonstrated good agreement with the TPS calculations, exhibiting a maximum error of only 0.5% for lung dose. Furthermore, the dose …
-
Exploring RayStation Treatment Planning System: Commissioning Varian TrueBeam Photon and Electron Energies, and Feasibility of Using FFF Photon Beam to Deliver Conventional Flat Beam
… dose measurements were completed using both the ArcCHECK phantom and the water tank. The majority of the results met the set criteria except for some measurements blocked by MLC leaves or jaws when taken adjacent to the edge of fields. To further confirm the goodness of modeled beams, clinical …
-
The Limit of Resolution and Detectability of the ArcCHECK QA Phantom in small field Volumetric Modulated Arc Therapy and Stereotactic Radiosurgery Quality Assurance
… the limit of detectability and resolution of the ArcCheck QA Phantom (Sun Nuclear, Inc.) for quality assurance of volumetric-modulated arc therapy and stereotactic radiosurgery procedures when used in small field sizes.Methods: Eight different square field sizes (0.6x0.6, 1x1, 2x2, 3x3, 5x5, 7x7, …