Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"Array coils"”

  1. Geometrically Decoupled Phased Array Coils for Mouse Imaging

    Phased array surface coils offer high SNR over a large field of view. Phased array volume coils have high SNR at the surface and centre of the volume. Most array coil designs typically employ a combination of geometrical and additional techniques, such as isolating preamplifiers for …

    tamu Repository record for Geometrically Decoupled Phased Array Coils for Mouse Imaging (opens in a new tab)

  2. Streamlining the Design and Use of Array Coils for In Vivo Magnetic Resonance Imaging of Small Animals

    … to achieve an increase in SNR through the use of array coils; however, the design, construction, and use of array coils for animal imaging remains challenging due to copper-loss related issues from small array elements and design complexities of incorporating multiple elements and associated array …

    tamu Repository record for Streamlining the Design and Use of Array Coils for In Vivo Magnetic Resonance Imaging of Small Animals (opens in a new tab)

  3. A machine learning based method for sensitivity estimation for accelerated magnetic resonance spectroscopy imaging using phased array coils

    … differences in receiver sensitivities in phased array coils to recover additional location information. Accurate estimation of the sensitivity profiles is necessary to prevent parallel imaging induced artifacts. However, accurate sensitivity profile estimations require fully sampled …

    uiuc Repository record for A machine learning based method for sensitivity estimation for accelerated magnetic resonance spectroscopy imaging using phased array coils (opens in a new tab)

  4. New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI

    … new methods to design radiofrequency (RF) arrays optimized for these purposes. Our approach is to design an eight-channel array coil that is both transmit and receive, and could be used for both types of studies. We focused on optimizing the array for the application of small field-of-view …

    manitoba Repository record for New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI (opens in a new tab)

  5. RF Array Coil Design for High-Field Magnetic Resonance Imaging and Spectroscopy

    Use of RF array coils for signal reception in magnetic resonance experiments is now commonplace due to their superior achievable SNR compared to conventional coils and their ability to dramatically reduce scan times through parallel imaging. When used as transmitters, arrays provide the additional …

    tamu Repository record for RF Array Coil Design for High-Field Magnetic Resonance Imaging and Spectroscopy (opens in a new tab)

  6. Application of Parallel Imaging to Murine Magnetic Resonance Imaging

    … typically small-bore systems. To that end, an array element design is described that inherently decouples from a homogenous transmit field, potentially allowing for elimination of typically necessary active detuning switches. The unbalanced feed of this "dual-plane pair" element also eliminates …

    tamu Repository record for Application of Parallel Imaging to Murine Magnetic Resonance Imaging (opens in a new tab)

  7. Designing novel radio-frequency coils for high field and ultra-high field magnetic resonance imaging

    … need for designing of new radio frequency (RF) coils. Here are presented several of these novel RF coils include multifilar helical antenna coils for 3-T, 4.7-T, 7-T and 10.5-T NMR scanners, slotted-waveguide array coils for 7-T, inverted microstrip array coil for 7-T along with other methods to …

    colostate Repository record for Designing novel radio-frequency coils for high field and ultra-high field magnetic resonance imaging (opens in a new tab)

  8. Design of Phased Array and Multiple Coil Probes for High Frequency Magnetic Resonance Microscopy and Spectroscopy

    … recent developments in the field of phased array coils have also been used to increase sensitivity. Typically, such an arrangement requires a homogeneous transmit coil, with the array being used only for signal reception. In this thesis a more flexible arrangement has been designed, in which …

    uiuc Repository record for Design of Phased Array and Multiple Coil Probes for High Frequency Magnetic Resonance Microscopy and Spectroscopy (opens in a new tab)

  9. Advancing RF coil technology for human brain magnetic resonance imaging at ultrahigh field

    … This thesis developed and evaluated RF head array coils integrated with HPM of different forms and relative permittivity values, aiming to significantly improve the strengths and spatial distribution of the RF coil B1 field, as well as the SNR and quality of various human brain imaging …

    umn Repository record for Advancing RF coil technology for human brain magnetic resonance imaging at ultrahigh field (opens in a new tab)

  10. An Investigation of Noise in Phased-Array Magnetic Resonance Images

    … More specifically, a standard protocol for RF coils of any number of channels is needed. This study presents a simple, practical SNR evaluation method for coils of any number of channels. In addition, a mathematical formula is presented that both determines the noise levels in different regions …

    marquette Repository record for An Investigation of Noise in Phased-Array Magnetic Resonance Images (opens in a new tab)

  11. Multi-Channel, Frequency-Agnostic, Portable Receiver Design for Magnetic Resonance Imaging and Spectroscopy

    … Exploiting the increased SNR provided by array coils is a natural direction to turn in addressing this; however, it is highly unusual for scanners to be equipped with multi-channel, multi-nuclear receivers due to cost and complexity. This leads to a “chicken or the egg” conundrum where …

    tamu Repository record for Multi-Channel, Frequency-Agnostic, Portable Receiver Design for Magnetic Resonance Imaging and Spectroscopy (opens in a new tab)

  12. A 16-Channel Receive Array Insert for Magnetic Resonance Imaging of the Breast at 7T

    … the availability of commercial radiofrequency coils for 7T. The primary objective of this work is to enable the study of breast cancer at 7T with the development of a 16-channel receive array coil. The use of array coils to receive is standard in clinical MRI, as it provides higher SNR over a …

    tamu Repository record for A 16-Channel Receive Array Insert for Magnetic Resonance Imaging of the Breast at 7T (opens in a new tab)

  13. Advancements in Multinuclear Multichannel NMR and MRI

    The introduction of receive arrays revolutionized ^1H MRI and in vivo NMR by increasing SNR and enabling accelerated imaging. All MRI scanners manufactured today are equipped to receive signals from ^1H array coils, but few support multi-channel reception for other nuclei. The extension of receive …

    tamu Repository record for Advancements in Multinuclear Multichannel NMR and MRI (opens in a new tab)

  14. Isolating Power Amplifiers for Parallel Transmit MRI

    … of theory of operation, their ability to isolate array coils, and the amount of power they can deliver to a coil. The current source amplifiers function by introducing a high impedance in series with the coil which is series resonant. In contrast, the low output impedance amplifiers present a low …

    tamu Repository record for Isolating Power Amplifiers for Parallel Transmit MRI (opens in a new tab)

  15. Toward Faster and Quieter MRI

    … and optimization of rectangular surface rf coils used for partially parallel imaging. The effect of passive copper shielding applied to the outside of an actively shielded gradient is studied with the aim of substantially reducing induced eddy currents in the cryostat inner bore. A ladder rf …

    ohiolink Repository record for Toward Faster and Quieter MRI (opens in a new tab)

  16. Radiofrequency Coil Design for Magnetic Resonance Imaging and Spectroscopy of the Human Breast and Models of Duchenne Muscular Dystrophy

    … benefits of high field MRI and the use of array coils have enabled studies such as dynamic contrast enhanced MRI (DCEMRI) and diffusion weighted imaging (DWI) with high spatial and/or temporal resolution. These studies provide additional information about morphology and kinetics of breast …

    tamu Repository record for Radiofrequency Coil Design for Magnetic Resonance Imaging and Spectroscopy of the Human Breast and Models of Duchenne Muscular Dystrophy (opens in a new tab)

  17. Design and Numerical Investigation of RF Transceiver Arrays for 7T MR Imaging in Humans

    … Modern magnetic resonance devices employ phased array coils made of low impedance resonant loops. Electrodynamic interactions between elements in such arrays must be carefully balanced. To mitigate inductive coupling, neighboring coil components are strategically overlapped, and preamplifier …

    buffalo Repository record for Design and Numerical Investigation of RF Transceiver Arrays for 7T MR Imaging in Humans (opens in a new tab)

  18. Réseau flexible de résonateurs à ligne de transmissions pour l'émission et la réception en IRM cardiaque à 7T

    Ce projet doctoral s’est déroulé dans le cadre d’une collaboration entre le laboratoire d’Imagerie par Résonance Magnétique Médicale et Multi-Modalités (IR4M) de l’Université Paris-Sud (France) et le Center for Medical Physics and Biomedical Engineering at Medical (CMPBME) de l’Université Médicale …

    star-france Repository record for Réseau flexible de résonateurs à ligne de transmissions pour l'émission et la réception en IRM cardiaque à 7T (opens in a new tab)

  19. Développements méthodologiques et techniques pour le contrôle qualité en imagerie par résonance magnétique

    De plus en plus utilisée en routine clinique, l'Imagerie par Résonance Magnétique (IRM) est très fréquemment associée à d'autres modalités d'imagerie médicale dans le cadre d'études multicentriques. Elle est également utilisée à des fins de quantification et sa technologie se complexifie, notamment …

    star-france Repository record for Développements méthodologiques et techniques pour le contrôle qualité en imagerie par résonance magnétique (opens in a new tab)

Page 1 of 2