Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 29 for “"Array probe"”

  1. Calculation of array probe response to sub-surface corrosion using edge element

    … a new analysis of a racetrack coil used with an array of magnetic field sensors. The later part is dedicated to finding a numerical solution to the problem of the interaction of the excitation coil with a flaw. The solution uses edge element basis functions for the expansion of the unknown field …

    iastate Repository record for Calculation of array probe response to sub-surface corrosion using edge element (opens in a new tab)

  2. Ultrafast ultrasound imaging for simultaneous extraction of flow and arterial wall motion with linear array probe

    Cette thèse présente un ensemble de travaux qui s'inscrivent dans le domaine du génie biomédical pour des applications cliniques. L'objectif principal de ce travail est de fournir aux cliniciens un mode d'imagerie ultrasonore pour extraire simultanément la vitesse du flux et le mouvement de la …

    star-france Repository record for Ultrafast ultrasound imaging for simultaneous extraction of flow and arterial wall motion with linear array probe (opens in a new tab)

  3. Design of Phased Array and Multiple Coil Probes for High Frequency Magnetic Resonance Microscopy and Spectroscopy

    … recent developments in the field of phased array coils have also been used to increase sensitivity. Typically, such an arrangement requires a homogeneous transmit coil, with the array being used only for signal reception. In this thesis a more flexible arrangement has been designed, in which …

    uiuc Repository record for Design of Phased Array and Multiple Coil Probes for High Frequency Magnetic Resonance Microscopy and Spectroscopy (opens in a new tab)

  4. Subwavelength Imaging using Scanning Near-field Antenna Arrays

    … thesis examines a series of near-field antenna arrays used to perform subwavelength focusing and subwavelength imaging outside the extreme near field. For this purpose, slot and dipole arrays have been designed to produce a subwavelength focal spot at a distance of a quarter wavelength from the …

    toronto-retro Repository record for Subwavelength Imaging using Scanning Near-field Antenna Arrays (opens in a new tab)

  5. Design and analysis of rotating field eddy current probe for tube inspection

    … the past two decades, three types eddy current probes developed for steam generator tube inspection include bobbin coil probe, rotating probe and array probe. Each of these probes has their own limitations.The bobbin coil probe is insensitive to circumferential cracks, and rotating probe is slow …

    msu Repository record for Design and analysis of rotating field eddy current probe for tube inspection (opens in a new tab)

  6. The use of electrical resistance tomography to determine the minimum agitation speed for solids suspension in stirred tank reactors

    … was developed and tested. Accordingly, a sensor array probe consisting of a straight plastic rod mounting 16 electrodes was placed vertically in a tank containing water and non-conductive glass beads approximately 300 ?m in diameter. The electrodes were connected to an external ERT system and …

    njit Repository record for The use of electrical resistance tomography to determine the minimum agitation speed for solids suspension in stirred tank reactors (opens in a new tab)

  7. Evaluating Hail Spectrometer Data Quality And Uncertainty For Calculating Radar Reflectivity Factor

    … data were processed using the System for Optical Array Probe Data Analysis Version 2 (SODA2) to enable dataset-wide comparison with the 1D measurements. Consistent discrepancies were found between the 1D and 2D particle size distributions, with the 1D data showing larger maximum particle sizes and …

    nodak Repository record for Evaluating Hail Spectrometer Data Quality And Uncertainty For Calculating Radar Reflectivity Factor (opens in a new tab)

  8. Sensitivity Of Two-Dimensional Stereo (2DS) Probe Derived Parameters To Particle Orientation

    … The two-dimensional stereo (2D-S) optical array probe (OAP) manufactured by SPEC, Inc. offers the capability for comparison between two orthogonal sample volumes (vertical and horizontal) and the determination of whether previously unknown errors in particle image aspect ratio, size …

    nodak Repository record for Sensitivity Of Two-Dimensional Stereo (2DS) Probe Derived Parameters To Particle Orientation (opens in a new tab)

  9. Investigation Of The Existence Of Vertically Oriented Ice Crystals In Winter Storms

    … these objectives, Two-Dimensional Stereo Optical Array Probe (2D-S) Image Data were meticulously analyzed to isolate low aspect ratio ice crystals, including columns, needles, and plates, based on predefined subset parameters. Histograms depicting orientation angles were constructed for each case, …

    nodak Repository record for Investigation Of The Existence Of Vertically Oriented Ice Crystals In Winter Storms (opens in a new tab)

  10. Exploring potential mechanisms responsible for observed changes of ultrasonic backscattered energy with temperature variations

    … The simulations were carried out with a linear array having 128 elements and center frequency of 5.5 MHz. Experiments were carried out by scanning physical phantoms containing randomly spaced glass beads with a Sonix RP scanner at every 0.5 ºC from 37 ºC to 48 ºC. Shifts in the backscattered …

    uiuc Repository record for Exploring potential mechanisms responsible for observed changes of ultrasonic backscattered energy with temperature variations (opens in a new tab)

  11. Transmit-Receive Eddy Current Non-Destructive Evaluation of Steam Generator Tubes and Additively Manufactured Materials: An Analytical and Experimental Investigation

    … success with a transmit-receive (T/R) array probe, and the other derived from Finite Element Method (FEM) simulations. An optimized T/R coil design was constructed and tested on Ti-5Al-5V-5Mo-3Cr (Ti5553) and Ti-6Al-4V (Ti64) samples containing sub-surface voids, as well as side and …

    queens Repository record for Transmit-Receive Eddy Current Non-Destructive Evaluation of Steam Generator Tubes and Additively Manufactured Materials: An Analytical and Experimental Investigation (opens in a new tab)

  12. Inspection of Ferromagnetic Support Structures From Within Alloy 800 Steam Generator Tubes Using Pulsed Eddy Current

    … SG tube and support structure conditions. An array probe consisting of a central driver, coaxial with the tube, and an array of 8 sensing coils, was used in this thesis to perform laboratory measurements. The probe was delivered from the inner diameter (ID) of the SG tube, where support hole …

    queens Repository record for Inspection of Ferromagnetic Support Structures From Within Alloy 800 Steam Generator Tubes Using Pulsed Eddy Current (opens in a new tab)

  13. Electromagnetic methods for measuring material properties of cylindrical rods and array probes for rapid flaw inspection

    … by using a 2D finite element code.;A new probe technology is designed which has an enhanced flaw detection capability and can reduce inspection time through the use of multiple magnetic field sensing elements. A preliminary Hall array probe has been built and test with eight individual …

    iastate Repository record for Electromagnetic methods for measuring material properties of cylindrical rods and array probes for rapid flaw inspection (opens in a new tab)

  14. Weld Defect Detection using Ultrasonic Phased Arrays

    … based on the manipulation of an ultrasonic probe by an experienced inspector are beginning to be replaced by Automated Ultrasonic Testing (AUT). Although largely limited to regular structures the integration of phased arrays and computer controlled mechanical manipulators allows AUT to …

    cent-lancashire Repository record for Weld Defect Detection using Ultrasonic Phased Arrays (opens in a new tab)

  15. Metallic material grain structure characterization using ultrasonic arrays

    … The main benefit of using ultrasonic<br/>phased arrays is that one array probe at one position can focus ultrasound beams at multiple<br/>points using different focal laws either physically or in data postprocessing. Potentially this means<br/>that accurate grain size measurements can be obtained …

    bristol Repository record for Metallic material grain structure characterization using ultrasonic arrays (opens in a new tab)

  16. Exploring Neurotransmitter Dynamics in Neurodegenerative Diseases Using Fast-Scan Cyclic Voltammetry: Mechanisms, Models, and Therapeutic Insights

    … voltammetry (FSCV), zinc photolysis, and nano-array sensors. In Chapter 2, we discuss the work we have done to induce Alzheimer’s disease in zebrafish. This study used okadaic acid to induce AD-like symptoms in adult zebrafish and assessed neurochemical and behavioral changes. OKA-treated fish …

    ku Repository record for Exploring Neurotransmitter Dynamics in Neurodegenerative Diseases Using Fast-Scan Cyclic Voltammetry: Mechanisms, Models, and Therapeutic Insights (opens in a new tab)

  17. Ultrasound as a non-invasive diagnostic tool in paediatric neurosurgery : relationship between the optic nerve sheath diameter (ONSD) and intracranial pressure (ICP)

    … using a high frequency, small footprint linear array probe, and prior to invasive ICP measurement. All patients were under general anaesthesia and being mechanically ventilated. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial …

    cape-town Repository record for Ultrasound as a non-invasive diagnostic tool in paediatric neurosurgery : relationship between the optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) (opens in a new tab)

  18. Robotic fastener hole inspection with 2D ultrasonic phased array

    … bolthole scanners and single-element ultrasonic probes, are limited: eddy current inspection requires fastener removal, while ultrasonic testing demands multiple probe positions for each hole and highly skilled operators. More advanced non-destructive testing (NDT) methods such as computed …

    bristol Repository record for Robotic fastener hole inspection with 2D ultrasonic phased array (opens in a new tab)

  19. Der Einfluss des Melkens auf Durchblutung und Morphologie der Rinderzitze untersucht mittels Color Angiographie und B-Mode Sonographie

    … XVISION® ultrasound scanner with a linear array probe. The analysis was supported by MyLab™Desk® as well as PixelFlux® software. During ultrasound scanning the right front teat was immersed in warmed contact jelly in an angled bowl. Measurements in cross section at the changeover of udder …

    lmu-germany Repository record for Der Einfluss des Melkens auf Durchblutung und Morphologie der Rinderzitze untersucht mittels Color Angiographie und B-Mode Sonographie (opens in a new tab)

Page 1 of 2