Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 33 for “"Arterial Input Function"”.
-
Measurement of the arterial input function from radial MR projections
… feeding the tissue - commonly referred to as the arterial input function (AIF). Physiologically relevant parameters are extracted through Pharmacokinetic modeling, though the accuracy is known to be highly sensitive to the quality of the acquired data. It is difficult to get a good measurement of …
-
Automated Determination of Arterial Input Function Areas in Perfusion Analysis
… requires the accurate determination of the arterial input function (AIF), which describes the delivery of intravascular tracers to tissues. Automating the process of finding the AIF can save operating time, remove the inter-operator variability, and correct the errors in the presence of the …
-
Improved Arterial Input Function For Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using Phase and T1 Measurements
Perfusion is a bodily function that describes the transport of blood and nutrients to an organ. If characteristics of the blood flow to an organ can be measured, clinically useful quantitative data about the organ can be obtained. This is particularly useful in the diagnosis of tumours as their …
-
Statistical modeling strategies for estimation of the arterial input function in dynamic positron emission tomography data analysis
… concentration in blood plasma, described by the arterial input function (AIF). Arterial blood sampling is the gold standard for AIF measurement, but is invasive and labour intensive. A number of methods have been proposed to accurately estimate the AIF directly from blood sampling and/or imaging …
-
Quantification of cardiac magnetic resonance imaging perfusion in the clinical setting at 3T
… the convolution of a model with the arterial input function (i.e. contrast agent concentration-time curve extracted from the left ventricular cavity) is fitted to the tissue contrast agent concentration-time curve. In contrast to dual bolus DCE-MRI protocols, single bolus protocols …
-
Quantification of cardiac magnetic resonance imaging perfusion in the clinical setting at 3T
… the convolution of a model with the arterial input function (i.e. contrast agent concentration-time curve extracted from the left ventricular cavity) is fitted to the tissue contrast agent concentration-time curve. In contrast to dual bolus DCE-MRI protocols, single bolus protocols …
-
Quantifizierung der Myokardperfusion mittels Dual Saturation Time Perfusion Imaging
… as an alternative to the prebolus-technique. The Arterial Input Function was determined using two different methods (‚KonFactor’- and ‚IndivFactor’-Method) in order to compare the calculated myocardial perfusion values with those of the prebolus-technique. In this study, there was no concordance …
-
DEVELOPING TARGETING AGENTS AND ADVANCED IMAGING TECHNIQUES FOR CANCER AND MOLECULAR IMAGING
… of accurately and noninvasively estimating the arterial input function (AIF) from dynamic PET images. Using convolutional neural networks (CNNs) and autoencoders, we develop methods to predict AIFs with high precision, reducing the need for invasive blood sampling. Further advancing the …
-
Augmented breast tumor classification by perfusion analysis
… solutions. The delivery of contrast agent as a function of time must also be determined or sampled before deconvolution can proceed. Some regions of the body, such as the brain, provide a nearby artery to serve as this arterial input function. Poor estimates can lead to an over or under …
-
Application of Independent Component Analysis (ICA) in Pharmacokinetic Modeling of Tumors Using Dynamic Contrast Enhanced (DCE)-MRI
… intravascular contrast agent concentration as an input. This vascular input function (VIF) is inseparable from the signal of extravascular extracellular space due to heterogeneity of tumor vasculature, partial volume effect, and low resolution of DCE-MRI. Thus, it is approximated with an arterial …
-
Protocol variation analysis of whole brain CT perfusion in acute ischemic stroke
… and manual contralateral selection of the arterial input function (AIF) and venous input function (VIF), along with the interchangeable combinations using singular value decomposition (SVD) and singular value decomposition plus (SVD+) deconvolution algorithms, CTP parametric maps are …
-
Quanitifying myocardial blood flow using dynamic contrast enhanced cardiac magnetic resonance imaging
… - the localisation of the myocardium and arterial input function (AIF) to generate signal intensity vs. time curves; - the conversion of signal intensity data to contrast agent concentration values; - the application of a perfusion model to generate a quantitative MBF estimate; - the …
-
Automatic Perfusion Imaging Analysis for the Prediction of Tissue Fate in Acute Ischemic Stroke using Machine Learning
… proposed a method to automatically select the arterial input function of computed tomography perfusion and perfusion-weighted MRI datasets. Using the baseline classical machine learning model design and proposed data preprocessing method, stroke tissue outcome predictions were generated to …
-
Methods for User and Procedural Bias Reduction in Quantitative Angiography of Intracranial Aneurysms
… variables. We standardize the arterial input function (AIF) by convolving impulse response function (IRF) with it, ensuring that the hemodynamic parameters reflect true physiological conditions rather than the artifacts introduced by the imaging process. However, even with …
-
QUANTIFICATION OF CORONARY FLOW VELOCITY VIA CONTRAST DISPERSION PATTERNS: INSIGHTS FROM COMPUTATIONAL MODELING AND COMPUTED TOMOGRAPHY EXPERIMENTS
… beyond coronary atherosclerosis to a suite of functional myocardial imaging options that now closely parallels magnetic resonance imaging; including ventricular function, viability and perfusion. Despite these advances, there are currently no existing CT based methods to assess coronary luminal …
-
Spatio-temporal image analysis with application to cancer
… in this work are PK model selection and arterial input function derivation, as well as intrasequence motion correction for dynamic imaging data. Registration of dynamic imaging data is a particularly challenging problem due to the variety of motion types that appear in these data: bulk …
-
Cancer imaging based on tissue biomarkers of phosphocholine synthesis
… effect, temporal resolution, and image-derived arterial input function reliability. The results of parametric modeling indicated that HCC could be distinguished from non-neoplastic hepatic tissue by the blood-to-tissue influx constant (k1) reflecting the activity of the membrane choline …
-
Nicht-invasive MRT-Perfusionsbildgebung für Diagnosestellung, Therapiemanagement und Prognoseabschätzung bei Patienten mit ischämischem Schlaganfall
… und nicht-invasive Bildgebungsverfahren wie arterial spin labeling (ASL) und phase-contrast (PC) Magnetresonanztomographie (MRT) gewinnen hier zunehmend an Bedeutung. Im Rahmen dieser Promotionsarbeit wurde die Anwendung von ASL bei Schlaganfall im chronischen, subakuten und hyperakuten …
-
4D reconstruction of oncological dynamic PET data
… parameter estimates by fitting smooth temporal functions to the voxel time-activity-curves (TACs) during the reconstruction. Cancer imaging studies often have many tissues within the scanner field of view, leading to a wide range of TAC shapes to be fitted. The development of flexible temporal …
-
Advanced Quantification of Myocardial Perfusion
… injected contrast agent in the tissue with the arterial input function (AIF). However deconvolution is inherently a difficult process and therefore numerically unstable with noise contaminated data.<br/>The purpose of this study is to enable high spatial resolution voxel-wise quantitative …
Page 1 of 2