Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 81 for “"Artifact reduction"”.
-
General artifact reduction scheme for laminography
… the x-ray source and the detectors. Another main artifact seen in a laminograph is the residual images of other features at depths other than the desired focal-plane. Since the shifting and the averaging processes are not perfect, certain features from the out-of-focal planes will still be …
-
Artifact reduction in functional magnetic resonance imaging
… oxygenation. However, fMRI studies are prone to artifacts caused by blood flow, variations in NMR signal phase, and patient motion. A new method of MR imaging called partial presaturation (PSAT) was developed that allows fMRI studies to be performed with reduced sensitivity to blood flow. The …
-
Motion Artifact Reduction in Impedance Plethysmography Signal
… addressing the problem of removing motion artifact from the electrocardiogram (ECG) and photoplethysmography (PPG) signals in the past few years. However, no such study exists for the Impedance Plethysmography (IP) signal. The IP signal can be used to monitor respiration in mobile devices. …
-
Quantitative evaluation of metal artifact reduction techniques in MRI
Several techniques for metal artifact reduction in MRI were studied in order to determine their effectiveness. The noise and blur introduced by the techniques were also investigated. To this end, non-metallic replicas of two metal implants (stainless steel and titanium/chromium-cobalt femoral …
-
Motion artifact reduction of electrocardiograms using multiple motion sensors
… the most problematic being that of motion artifacts. As an individual wearing a surface ECG moves, their movements will add noise to the signal. This noise is particularly difficult to remove, as it will change depending on the movements of the user and will often fall in the same spectrum …
-
Laminography: artifact reduction scheme for objects with complex geometry
… laminograph these undesirable features, known as artifacts, are visible, and they confuse the perception of the viewer. It is desirable to remove these artifacts or at least reduce their effect. For simple objects like a printed circuit board (PCB), the artifacts are in the same focal plane. …
-
Motion Artifact Reduction From Non-Contact ECG Recording Systems
… However, a significant challenge remains; motion artifacts (MAs) caused by body movements and physiological vibrations. Such artifacts can significantly compromise diagnostic accuracy and may even lead to misinterpretations of cardiovascular conditions. To address this, this PhD research begins by …
-
Artifact reduction in cardiac MRI in patients with varying heart rate
… simulation were developed.It focuses on how artifacts are created when patients with varying heart rate are imaged. The IR simulation was evaluated experimentally and was found to provide values matching the measured within 5%. A novel method to reduce the strength of the artifacts through …
-
Algorithms for enhanced artifact reduction and material recognition in computed tomography
… Metal and dense objects create image artifacts which degrade the image quality and deteriorate the recognition accuracy. Conventional CT machines scan the object using single source or dual source spectra and reconstruct the effective linear attenuation coefficient of voxels in the …
-
Artifact Reduction Strategy for Radar-based Microwave Imaging Designed for Medical Applications
… the data processing flow. These distortions or artifacts can be reduced by filtering the frequency data but with a loss in time domain resolution. Fourier Shift Manipulation (FSM) was explored as an alternative pre-processing technique that utilizes fundamental discrete Fourier transform (DFT) …
-
Deep learning-based metal and scatter artifact reduction in conebeam computed tomography
… image quality is often compromised by inherent artifacts, including scatter and metal artifacts, which pose significant challenges to diagnostic applications. The emergence of deep learning methods presents a promising avenue for addressing these imaging challenges, potentially offering …
-
Wire loop motion sensor optimization for artifact reduction in EEG-fMRI recordings
… high temporal resolution of EEG. However, the artifacts observed in EEG during this combined recording method have posed a challenging problem. The high magnetic field creates these artifacts via Faraday's law of induction whenever the field shifts during imaging or when the subject moves in …
-
Cross-Scatter in Dual-Cone X-ray Imaging: Magnitude, Avoidance, Correction, and Artifact Reduction
… therapy; however, it is susceptible to metal artifacts and beam-hardening artifacts that can hinder visualization of low contrast anatomy. Dual-CBCT provides easy access to techniques that may reduces such artifacts. Additionally, dual-CBCT can decrease imaging time and provide simultaneous …
-
Deep Learning for CT Image Enhancement and Segmentation: Metal Artifact Reduction and Airway Segmentation
… evaluated a private tooth dataset with metal artifacts based on the subsequent tooth segmentation shows our method provides better quality and semantic consistency. The second study presents a volumetric airway segmentation method from chest CT volumes. Large-kernel attention modules are …
-
Artifact Reduction In The Integration Of Neural Electrodes And Extracellular Recording With Ultrahigh Field Magnetic Resonance Imaging
… distortions by the electrodes that create image artifacts in MRI, as well as electromagnetic inductive coupling that introduces noise and interferences in the extracellular neural signal recordings made at UHF. This dissertation develops solutions to address both types of interferences. The MRI …
Page 1 of 5