Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"Artificial hearts"”

  1. An Effective Transcutaneous Energy Transfer (TET) System for Artificial Hearts

    … as cochlear implants, cardiac pacemakers and artificial heart pumps, consume electrical energy for the lifetime of the patient. The method of power delivery in these devices is principally dependent on their power requirements. Low power implantable devices, such as cardiac pacemakers …

    auckland-ms Repository record for An Effective Transcutaneous Energy Transfer (TET) System for Artificial Hearts (opens in a new tab)

  2. Optimal control of time-dependent viscous flow with potential application to artificial hearts.

    … viscous flows. Some specific designs of artificial hearts are described briefly, followed by a review on common hemodynamic problems created by artificial hearts and heart valves. Some mathematical models for certain types of artificial hearts are formulated. Optimal control theory has …

    ottawa-retro Repository record for Optimal control of time-dependent viscous flow with potential application to artificial hearts. (opens in a new tab)

  3. The Pharmacodynamics and Toxicodynamics of Inotropic Drugs in Calves With Natural and Artificial Hearts

    … is the use of an animal with an implanted total artificial heart (TAH). Three inotropic drugs, dobutamine, enoximone, and pimobendan, were tested in eight animals with their natural heart intact and five animals implanted with a TAH. Baseline values of the TAH and natural heart (NH) were compared …

    utahstate Repository record for The Pharmacodynamics and Toxicodynamics of Inotropic Drugs in Calves With Natural and Artificial Hearts (opens in a new tab)

  4. Analysis of Time-Periodic Navier-Stokes Equations in a Moving Domain and Numerical Computations with Radial Basis Neural Networks: Application to Artificial Hearts Blood Flow

    The dynamics of blood flow within an artificial heart (AH) chamber are governed by the time-periodic Navier-Stokes (NS) equations. These equations are coupled with a hyperbolic partial differential equation (PDE) that describes the dynamic behavior of the membrane (diaphragm). This coupled system …

    ottawa-retro Repository record for Analysis of Time-Periodic Navier-Stokes Equations in a Moving Domain and Numerical Computations with Radial Basis Neural Networks: Application to Artificial Hearts Blood Flow (opens in a new tab)

  5. Aplicações e desafios em biomateriais poliméricos para fabricação de corações artificiais e dispositivos cardiovasculares

    … Relevant cases of synthetic heart valves and artificial hearts based on advanced materials, such as polycarbonate urethane (PCU), POSS-PCU, SiPUU, and FGO-PCU, are analyzed. These polymers have demonstrated excellent fatigue resistance, flexibility, and low susceptibility to calcification, …

    brazil-ufscar Repository record for Aplicações e desafios em biomateriais poliméricos para fabricação de corações artificiais e dispositivos cardiovasculares (opens in a new tab)

  6. Investigations into inductive propulsion for centrifugal blood pumps

    … type of blood pumps and several models of these artificial hearts have even been made commercially available. However their usage is not widespread yet as there are still many areas in need of improvements. To overcome some of the current drawbacks, and also to advance the knowledge of …

    nanyang Repository record for Investigations into inductive propulsion for centrifugal blood pumps (opens in a new tab)

  7. Measurements in a 5:1 enlarged bio-centrifugal pump model

    … pump has shown its superiority compared to other artificial hearts, however, thombosis is found in the pump especially in the 0.2mm casing/impeller gap. It is thus required to find out the fluid mechanics related issues in the pump that are useful guidelines for the further computational and …

    nanyang Repository record for Measurements in a 5:1 enlarged bio-centrifugal pump model (opens in a new tab)

  8. Measurements in a 5:1 enlarged bio-centrifugal pump model

    … pump has shown its superiority compared to other artificial hearts, however, thombosis is found in the pump especially in the 0.2mm casing/impeller gap. It is thus required to find out the fluid mechanics related issues in the pump that are useful guidelines for the further computational and …

    nanyang Repository record for Measurements in a 5:1 enlarged bio-centrifugal pump model (opens in a new tab)

  9. Design and Development of an Intra-Ventricular Assistive Device For End Stage Congestive Heart Failure Patients: Conceptual Design

    … other ventricular assistive devices or total artificial hearts the absence of pistons, impellers, bearings, housings, bladders and valves makes the manufacturing, inspection and maintenance processes much simpler. The device will also reduce the risk of calcification, wearing out or other …

    ohiolink Repository record for Design and Development of an Intra-Ventricular Assistive Device For End Stage Congestive Heart Failure Patients: Conceptual Design (opens in a new tab)

  10. Development of an enclosed-impeller ventricular assist device using self-bearing motor

    … there is an increasing need for implantable artificial hearts as an alternative to donor hearts which cannot meet the needs. The development of magnetically suspended Ventricular Assist Devices (VADs), alias blood pumps, has been a promising option for this purpose in recent years. In order …

    nanyang Repository record for Development of an enclosed-impeller ventricular assist device using self-bearing motor (opens in a new tab)

  11. Synthesis and surface modification studies of biomedical polyurethanes to improve long term biocompatibility

    … products such as catheters, vascular grafts and artificial hearts. An intense research is being conducted towards the synthesis of new hemocompatible materials and mdifications of surfaces with biological molecules. In this study, polyurethane (PU) films were synthesized in medical purity from …

    metu Repository record for Synthesis and surface modification studies of biomedical polyurethanes to improve long term biocompatibility (opens in a new tab)

  12. An Examination of Spiritual and Religious Coping and Well-Being and their Impact on the Health-Related Quality of Life for Patients with Mechanical Circulatory Support

    … left ventricular assist devices (HMII) and total artificial hearts (TAH). Patients were assessed pre and post MCS implant. Patients reported an increase in the use of faith practices for coping (prayer and meditation), providing evidence for spiritual growth after MCS. SWB, RWB, and CSM, and their …

    vcu Repository record for An Examination of Spiritual and Religious Coping and Well-Being and their Impact on the Health-Related Quality of Life for Patients with Mechanical Circulatory Support (opens in a new tab)

  13. Analysis and experiments on flow-induced hemolysis.

    … in flows within hypodermic needles, blood pumps, artificial hearts and other cardiovascular devices, is one of the major concerns during the design and use of cardiovascular or blood-processing extracorporeal devices. A non-invasive experimental method which does not interfere directly with red …

    louisville Repository record for Analysis and experiments on flow-induced hemolysis. (opens in a new tab)

  14. Design criteria of a transcutaneous power delivery system for implantable devices.

    Implantable cardiac assist devices such as artificial hearts and blood pumps are a rapidly growing therapy used for treating moderate to severe congestive heart failure. While current treatments offer improved heart failure survival and increased patient functionality with enhanced quality of life, …

    central-ok Repository record for Design criteria of a transcutaneous power delivery system for implantable devices. (opens in a new tab)

  15. Resolving Flow Properties of Spiral Groove Bearings to Improve Mechanical Circulatory Support Hemocompatibility

    … devices) or replace the heart entirely (total artificial hearts), using impellers, or a rotating set of blades, to drive blood flow to the systemic and/or pulmonary circulation. These pumps have been used in the clinic for decades, supporting patients for 1.5 years on average, but the …

    rice Repository record for Resolving Flow Properties of Spiral Groove Bearings to Improve Mechanical Circulatory Support Hemocompatibility (opens in a new tab)

  16. Differenziamento macrofagico: gli effetti dei polimeri sintetici

    … grafts, ventricular assist devices, total artificial hearts) due to their good mechanical properties and hemocompatibility (Zdrahala R.J. and Zdrahala I.J., 1999). In the biocompatibility evaluation of these synthetic polymers, that is important for its potential use in clinical …

    bologna Repository record for Differenziamento macrofagico: gli effetti dei polimeri sintetici (opens in a new tab)

  17. Enhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator

    … as ventricular assist devices (VADs) and total artificial hearts (TAHs), for patient treatment. These devices assist the failing heart by taking over the blood pumping process either partially or completely and must be properly vetted and verified for human use by undergoing many years of …

    texas Repository record for Enhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator (opens in a new tab)

Page 1 of 2