Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"Artificial knee."”

  1. On the design procedure of an artificial knee joint

    concordia

  2. 3D Printed PCU/UHMWPE Polymeric Blends for Artificial Knee Meniscus

    3D printing was used to fabricate porous artificial knee meniscus material from biocompatible polymeric blends of polycarbonate-urethane (PCU) and ultra-high-molecular-weight polyethylene (UHMWPE) to enable “weep” lubrication that mimics the native meniscus. 3D printed and molded pure PCU, as well …

    arkansas Repository record for 3D Printed PCU/UHMWPE Polymeric Blends for Artificial Knee Meniscus (opens in a new tab)

  3. Design of a passive retarding system for an artificial knee joint.

    Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Thesis. 1973. B.S.

    mit Repository record for Design of a passive retarding system for an artificial knee joint. (opens in a new tab)

  4. High flexion kinematics and kinetics for the improvement of artificial knee joints

    Total knee arthroplasty has been effective in reducing pain, but less so in restoring function, especially for activities requiring deep knee flexion. The philosophy of this dissertation was that more functionally effective and optimally designed artificial knees could be created for high flexion …

    queens Repository record for High flexion kinematics and kinetics for the improvement of artificial knee joints (opens in a new tab)

  5. The Synthesis of Azides from Alcohols using Sulfonyl Azides

    … synthesis of a possible monomer for use as an artificial knee cartilage.

    ohiolink Repository record for The Synthesis of Azides from Alcohols using Sulfonyl Azides (opens in a new tab)

  6. Kinematic design of an anatomically-accurate exoskeleton knee joint

    … study attempts to synthesize a two-dimensional artificial knee joint that accurately mimics the motion of its biological counterpart. Kinematic analysis and optimization have been carried out to virtually test the performance of the new design.

    ttu Repository record for Kinematic design of an anatomically-accurate exoskeleton knee joint (opens in a new tab)

  7. Dynamic Measurements of Lubrication Film Thickness of UHMWPE Contacts for Total Joint Replacements

    … First, the laboratory's force-controlled knee joint simulator was used while dynamic contact pressure measurements under both dry and lubricated conditions were made using the sensor technology employed in two different artificial knee implant geometries. Each implant was machined by the …

    clemson Repository record for Dynamic Measurements of Lubrication Film Thickness of UHMWPE Contacts for Total Joint Replacements (opens in a new tab)

  8. Knee mechanism performance in amputee activity

    … which can be incorporated into the shank of an artificial leg for a patient with a below knee or higher levels of amputation. Together with a goniometer at the artificial knee joint, this enabled sufficient information to be recorded to calculate the force actions exerted between the socket and …

    strathclyde Repository record for Knee mechanism performance in amputee activity (opens in a new tab)

  9. Customized surface-guided total knee replacement for natural kinematics and deep flexion

    Total knee replacements (TKRs) are developed to improve the quality of the life of patients by relieving pain and restoring normal knee function. The motivation of this dissertation was to develop and evaluate a TKR that provides close to normal kinematics for all flexion ranges, including deep …

    manitoba Repository record for Customized surface-guided total knee replacement for natural kinematics and deep flexion (opens in a new tab)

  10. Improvement of the Tribological Performance of UHMWPE-Based Composites for Artificial Joints

    More than two million artificial knee and hip joints are implanted every year, mainly due to osteoarthritis. The clinical survivorship of artificial joints (AJs) decreases significantly after the first 10 years of being implanted, in particular for patients younger than 55 years, with a reported …

    unsw Repository record for Improvement of the Tribological Performance of UHMWPE-Based Composites for Artificial Joints (opens in a new tab)

  11. Development of an unconstrained two-force dynamic simulator for the human knee joint

    This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca. The full policy for eScholarship may be …

    mcgill Repository record for Development of an unconstrained two-force dynamic simulator for the human knee joint (opens in a new tab)

  12. Feasibility and design study for a motorized A/K prosthesis.

    Thesis (B.S.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1978.

    mit Repository record for Feasibility and design study for a motorized A/K prosthesis. (opens in a new tab)

  13. Getting Back to the Future: A Grounded Theory Study of the Patient Perspective of Total Knee Joint Arthroplasty

    … describes the experience of undergoing total knee joint arthroplasty in the New Zealand public health system from the participants’ perspectives. The data sources were tape-recorded interviews, observation and published literature. There were nine participants, eight of whom underwent a …

    auckland-tech Repository record for Getting Back to the Future: A Grounded Theory Study of the Patient Perspective of Total Knee Joint Arthroplasty (opens in a new tab)

  14. Three velocity modulated myoelectric A/K prosthesis controllers ; initial subject evaluation

    Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1982.

    mit Repository record for Three velocity modulated myoelectric A/K prosthesis controllers ; initial subject evaluation (opens in a new tab)

  15. Stress compatible finite elements for bimaterial interface problems

    This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca. The full policy for eScholarship may be …

    mcgill Repository record for Stress compatible finite elements for bimaterial interface problems (opens in a new tab)

  16. An investigation of polyethylene bearing wear of New Jersey LCS knee on cobalt chromium and titanium nitride types

    The total knee replacement systems (TKRS) are used for the treatment of osteoarthritis and rheumatoid arthritis. Excessive wear can substantially shorten their life span. Two tests were performed to examine the wear characteristics of tibial bearings used in TKRS. Each test consisted of six sets of …

    njit Repository record for An investigation of polyethylene bearing wear of New Jersey LCS knee on cobalt chromium and titanium nitride types (opens in a new tab)

Page 1 of 2