Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 37 for “"Atomic Spectrometry"”
-
Trends in Tungsten Coil Atomic Spectrometry
Renewed interest in electrothermal atomic spectrometric methods based on tungsten coil atomizers is a consequence of a world wide increasing demand for fast, inexpensive, sensitive, and portable analytical methods for trace analysis. In this work, tungsten coil atomic absorption spectrometry …
-
NON-TRADITIONAL CALIBRATION STRATEGIES FOR APPLICATIONS IN ATOMIC SPECTROMETRY
Calibration is one of the most important steps of any analytical chemistry procedure. The selection of an appropriate calibration strategy, therefore, is of utmost importance when beginning any analysis. In the field of analytical chemistry, there are three most commonly used calibration methods: …
-
Speciation of Mercury by Chromatography Coupled with Atomic Spectrometry
… This instrument couples a GC oven to a modified atomic fluorescence detector via a ceramic pyrolyser. Organomercury compounds in dichloromethane solvent were directly injected through a Programmable Temperature Vaporiser Injector onto a DBl Megabore column. Once separated, the compounds eluted …
-
Sample preparation and heavy metal determination by atomic spectrometry /
… digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level …
-
On-line Systems For Automated Sample Introduction In Atomic Spectrometry
Automation has become increasingly common in most areas of human endeavour. In the field of analytical chemistry, particular attention has been paid to on-line systems which offer high sample throughput. Among other attributes, such systems also offer advantages in terms of ease of automation and …
-
New Approaches to High Efficiency Inductively Coupled Plasma Analytical Atomic Spectrometry
… performance, in the second place, for analytical atomic spectrometry. In the first strategy, a system was designed to collect the exhaust argon from the interface of an ICP-MS system, purify it, and recycle it back to the ICP torch. The experiments showed that the argon collection system was …
-
On-line Sample Pretreatment Of Environmental Samples For Use With Atomic Spectrometry
… for on-line sample pre-treatment for use with atomic spectroscopy. Preconcentration of the analytes using either complexation of the analyte(s) on an analytical column or by in-situ (in atomiser) trapping on a pre-coated graphite tube has been used. The samples were manipulated using flow …
-
The on line determination of mercury in process streams using atomic spectrometry
… and waste streams have been developed, utilising atomic fluorescence spectrometry (AFS) as the basis for detection. Instrumentation has been designed for unattended continuous operation. Laboratory chemistries for the vapour generation of mercury, normally performed off-line in batch mode, have …
-
Preconcentration of volatile elements on quartz surface prior to determination by atomic spectrometry
Hydride generation technique is frequently used for the detection of elements as As, Se, Sb, Sn, Bi, Ge, Te and Pb that form volatile hydrides in solution using a reductant. In this study, a novel quartz trap for on-line preconcentration of volatile analyte species was designed. Pb, Sb and Cd were …
-
Ultrasonic Cavitation and UV-Photogeneration of Hydrides for Improved Sample Introduction Efficiency in Atomic Spectrometry
Arsenic is a common and important pollutant. One common method of arsenic sample introduction is by using hydride generation. Hydride Generation is a method by which a non-volatile precursor (ionic or metal species) is made into a volatile species by reaction with hydrogen (in the form of a hydride …
-
The evaluation of a low powered microwave induced plasma as an atom cell for atomic spectrometry
… induced plasma is evaluated as an atom cell for atomic spectrometry. The modes of spectrometry evaluated are atomic emission and atomic fluoresence. Analytical merits of the microwave induced plasma using detection limits and studies of interelement effects (i.e. vaporization, ionizationâ and …
-
In-situ Preconcentration Of Trace Metals In Natural Waters And Brines With Analysis By Flow Injection Atomic Spectrometry
Atomic spectrometric techniques such as ICP-MS offer exceptional sensitivity and multi-element capability for trace metal analysis but the formation of polyatomic ions (particularly below m/z = 80) can cause serious interferences. Such interfering species may be introduced via precursor atoms in …
-
Development of automatic methods for trace metals determination using on-line separation and preconcentration techniques coupled with atomic spectrometry
… of flow injection analysis (FIA) with atomic absorption spectrometry has revolutionized the analytical methods and techniques. Most attention is focused on the development new methods analytical techniques. Three of on-line preconcentration methods have been developed for cadmium and …
-
Interference effects of hydride forming elements on bismuth determination using tungsten coil system as electrothermal vaporizer and electrothermal atomizer in atomic spectrometry /
… become an alternative tool for graphite tubes in atomic spectrometry for its high melting point, good electrical conductivity and low cost. Tungsten coil systems have been used in atomic spectrometry as both atomizers and vaporizers. Both approaches include advantages and disadvantages. In this …
-
Bridging the Gap Between Chemical Analysis and Applied Statistics to Expand the Applications of Atomic Spectrometric Techniques
… techniques is an important contribution to atomic spectrometry and its application to a broad range of research fields. With temperatures as high as 10,000 K, the inductively coupled plasma (ICP) is a robust source of atomization, excitation and ionization, capable of providing trace level …