Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 32 for “"Audiometry, Speech"”.

  1. Comparing the effects of a carrier phrase for NU-6 words on normal hearing and hearing impaired subjects

    … case history, otoscopy, tympanometry, pure tone audiometry, speech reception thresholds and word recognition testing via recorded Northwestern University #6 word lists. Each subject was administered a word list with a carrier phrase and a word list without a carrier phrase. The goal of this study …

    mo-state Repository record for Comparing the effects of a carrier phrase for NU-6 words on normal hearing and hearing impaired subjects (opens in a new tab)

  2. Speech audiometry in Cantonese and other non-native English speakers : the use of digits and Cantonese words as stimuli

    … and accuracy issues with the use of English speech audiometry on non-native English speakers. Two widely used tests of speech audiometry, Speech Recognition Threshold (SRT) and Word Recognition Score (WRS) were measured on 45 participants with English as a non-native language. The effects of …

    ubc Repository record for Speech audiometry in Cantonese and other non-native English speakers : the use of digits and Cantonese words as stimuli (opens in a new tab) Download PDF for Speech audiometry in Cantonese and other non-native English speakers : the use of digits and Cantonese words as stimuli (opens in a new tab)

  3. Development of an Audiological Test Procedure Manual for First Year Au.D. Students

    … Standards Institute (ANSI) and the American Speech-Language-Hearing Association (ASHA)] are not consistently used by the different sources. Thus, there is no standard procedural manual containing laboratory assignments that lead to the development of appropriate clinical testing skills by a …

    usf Repository record for Development of an Audiological Test Procedure Manual for First Year Au.D. Students (opens in a new tab)

  4. ACCURACY, SPEED AND EASE OF FILTERED SPEECH INTELLIGIBILITY.

    … an "objective" and a "subjective" test of speech intelligibility accuracy (SIA), speed (SIS) and ease (SIE) for different levels of low-pass filtered speech. During objective testing subjects listened to monosyllabic words low-pass filtered through an earphone, and repeated words as …

    arizona-thes Repository record for ACCURACY, SPEED AND EASE OF FILTERED SPEECH INTELLIGIBILITY. (opens in a new tab)

  5. A Comparison of Two Systems Used in the Electro-Acoustic Evaluation of Hearing Aids

    The purpose of this study is to compare the Fonix Type 5000 Hearing Aid Test Set to the B&K system by testing the same hearing aids with both systems in order to determine whether there are any important differences between the measurements obtained using the two systems. Frequency response has …

    portland-state Repository record for A Comparison of Two Systems Used in the Electro-Acoustic Evaluation of Hearing Aids (opens in a new tab)

  6. The use of auditory brainstem responses in determining the maximum outputs of hearing aids

    Uncomfortable listening level (UCL) is a behavioral measure which is currently used to set the maximum outputs of hearing aids. This study explored the feasibility of prescribing the maximum outputs of hearing aids by using results obtained from auditory brainstern response (ABR) testing. More …

    portland-state Repository record for The use of auditory brainstem responses in determining the maximum outputs of hearing aids (opens in a new tab)

  7. Output of compression hearing aids with transient and continuous input stimuli

    The purpose of this study was to determine whether the compression circuit of a hearing aid could be activated by a high frequency biasing tone such that its output for a transient stimulus could be made to approximate that of a continuous tone alone. Sufficient compression activation by a …

    portland-state Repository record for Output of compression hearing aids with transient and continuous input stimuli (opens in a new tab)

  8. The Interaction of Stimulus Rate and Polarity Effects on the Auditory Brainstem Response

    Research on the Auditory Brainstem Response (ABR) has been dominated by attempts to develop techniques to enhance the clarity of the ABR waveform and to define the parameters that separate normal from abnormal responses. While the effects of stimulus rate are clearly documented, the effects of …

    portland-state Repository record for The Interaction of Stimulus Rate and Polarity Effects on the Auditory Brainstem Response (opens in a new tab)

  9. Speech Reception Threshold Materials for Taiwan Mandarin

    Speech reception threshold (SRT) tools have been developed to assist in the evaluation of hearing. This study was performed to develop, digitally record, evaluate, and equate Taiwan Mandarin trisyllabic words which can be used to measure the SRT. Eighty-nine commonly used trisyllabic words were …

    byu Repository record for Speech Reception Threshold Materials for Taiwan Mandarin (opens in a new tab) Download PDF for Speech Reception Threshold Materials for Taiwan Mandarin (opens in a new tab)

  10. Development and Validation for a Mobile Speech-in-Noise Audiometric Task

    Traditional speech-in-noise hearing tests are performed by clinicians with specialized equipment. Furthermore, these tasks often present contextually weak sentences in background babble, which are poor representations of real-world situations. This study proposes a mobile audiometric task, Semantic …

    wustl Repository record for Development and Validation for a Mobile Speech-in-Noise Audiometric Task (opens in a new tab)

  11. Masking Patterns of High Frequency Pure Tones

    Previous investigations of masking have established that the action of the masking tone spreads upward in frequency, creating significantly more masking (threshold shift) above the masker frequency than below. It was the purpose of this study to investigate the masking pattern produced by high …

    portland-state Repository record for Masking Patterns of High Frequency Pure Tones (opens in a new tab)

  12. Speech reception via bone conduction

    … between the performance-intensity function of speech via bone conduction as compared to speech via air conduction. Also, there was no difference between the Radioear b-72 and Pracitronic KH-70 bone conduction vibrators. Discrimination scores also gave similar results between transducers. In …

    portland-state Repository record for Speech reception via bone conduction (opens in a new tab)

Page 1 of 2