Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 57 for “"Auger electrons"”

  1. Cellular damage by Auger electrons from ¹²³ I

    Auger electrons have the potential for therapy mainly because of their short range and high level of toxicity. Biological effects of these electrons are critically dependent on the cellular and subcellular localization of their emitters. In this study 123I was used due to its relatively short …

    nwu-za Repository record for Cellular damage by Auger electrons from ¹²³ I (opens in a new tab)

  2. Auger Electrons Associated with Stopped π- Interactions in Nuclear Emulsions

    The Mesonic Auger effect has been the subject of extensive theoretical and experimental investigations during the last several years. The purpose of this study is to determine with more precision, by means of increased statistics, the frequency of Auger electrons from n- meson interactions in …

    marquette Repository record for Auger Electrons Associated with Stopped π- Interactions in Nuclear Emulsions (opens in a new tab)

  3. Accurately determining the number of Auger electrons per nuclear decay for medical isotopes

    Auger-emitting radionuclides have great potential in cancer treatment as low-energy Auger electrons (below 5 keV) deposit a high radiation dose over a very short distance. Auger-based therapy is attractive as, in contrast to alpha and beta particles, the affected volume around the decaying …

    anu Repository record for Accurately determining the number of Auger electrons per nuclear decay for medical isotopes (opens in a new tab)

  4. Novel approaches to target infectious diseases: the utility of Auger electrons and scFvs for imaging and control

    … therapy, with particular interest in Auger electron radiation. Auger electrons are short range and low energy particles emitted from a range of radioactive isotopes. As a targeting agent, the antimicrobial peptide fragment UBI 29-41 was used. Antimicrobial peptides have a broad range …

    kent Repository record for Novel approaches to target infectious diseases: the utility of Auger electrons and scFvs for imaging and control (opens in a new tab)

  5. Measurements of the cusp electron peak in coincidence with target recoil ions and in coincidence with LMM Auger electrons produced in ionizing collisions for the 3 MeV Cℓ + Ar collision system

    … apparatus. The new spectrometer detects electrons emitted at 0° relative to the incident beam direction. It is a 30° parallel plate electrostatic spectrometer which uses a channel electron multiplier for electron detection. This forward parallel plate analyzer is added to a multi - …

    ut-knoxville Repository record for Measurements of the cusp electron peak in coincidence with target recoil ions and in coincidence with LMM Auger electrons produced in ionizing collisions for the 3 MeV Cℓ + Ar collision system (opens in a new tab)

  6. Metal-chelating Polymers for Auger Electron Radioimmunotherapy

    … types of breast cancer cells. 111In can generate Auger electrons which are able to induce the lethal cleavage of nuclear DNA. The strategy of labeling tmFab-SAv with Bi-MCP should enhance the number of 111In delivered per HER2 targeting event, and thereby increase the radiotoxicity delivered to …

    toronto-retro Repository record for Metal-chelating Polymers for Auger Electron Radioimmunotherapy (opens in a new tab)

  7. A comparison of three gadolinium based approaches to cancer therapy

    … (Gd), which produces internal conversion and Auger cascade electrons upon absorbing thermal neutrons. The low energy, nanometer-range, Auger electrons are absorbed locally and significantly increase cell killing when Gd binds to DNA. Two other methods induce Auger electrons in gadolinium …

    mit Repository record for A comparison of three gadolinium based approaches to cancer therapy (opens in a new tab)

  8. Auger and conversion electron spectroscopy of medical isotopes and the construction of a new atomic radiation database

    A localized source of electrons can be provided by radioisotopes that emit Auger electrons through atomic relaxation as part of their electron capture and/or internal conversion decays. Most of these Auger electrons could deposit their energies over short distances (nanometre to micrometre) in …

    anu Repository record for Auger and conversion electron spectroscopy of medical isotopes and the construction of a new atomic radiation database (opens in a new tab)

  9. Probing the ultrafast dynamics of 2-Thiouracil with soft x-rays

    … Laser. The kinetic energy of the emitted electrons is measured in a magnetic bottle spectrometer. The spectra of the measured photo and Auger electrons are used to derive a picture of the changes in the geometrical and electronic configurations. The results allow us to look at the …

    potsdam-diss Repository record for Probing the ultrafast dynamics of 2-Thiouracil with soft x-rays (opens in a new tab)

  10. Coincidence measurements of cascade Auger electron emission processess in photon-atom interactions and autoionization of electrons from doubly excited states of helium produced by fast ion impact

    … before. A CMA was used to observe simultaneously electrons ejected between 47.7° and 132.3° with respect to the ion-beam direction. Comparison of the data with several calculations was made to understand the mechanisms responsible for the production of these states. The relative electron emission …

    utk-theses Repository record for Coincidence measurements of cascade Auger electron emission processess in photon-atom interactions and autoionization of electrons from doubly excited states of helium produced by fast ion impact (opens in a new tab)

  11. Coincident detection of electrons ejected at large angles and target recoil ions produced in multiply-ionizing collisions for the 1MeV/uO[q+](q=4,7) + Ar collision system

    … This new multi-spectrometer system can detect electrons ejected at 0°, 180°, and into an angular range from about 45° to about 135° measured relative to the incident beam direction as well as the recoil ions produced in ion-atom collisions. A charge state analyzer allows one to determine the …

    utk-theses Repository record for Coincident detection of electrons ejected at large angles and target recoil ions produced in multiply-ionizing collisions for the 1MeV/uO[q+](q=4,7) + Ar collision system (opens in a new tab)

  12. Anisotropic effects following inner shell ionization.

    … phenomenon of the angular distribution of Auger electrons following inner shell ionization by electrons (Cleff and Mehlhorn, 1971). By extending the Bethe theory to include relativistic corrections after the manner of Miller (1932) it is shown (Chapter 6) that the polarization approaches …

    stirling Repository record for Anisotropic effects following inner shell ionization. (opens in a new tab)

  13. Evaluation of 64Cu-ATSM in cell culture for potential use as a radiotherapy agent

    … the decay mechanism of 64Cu which emits high LET Auger electrons. Presently, the biological mechanism for cell killing and DNA damage due to high LET electrons released in the decay of 64Cu is unknown. To evaluate how high LET Auger electrons play a role in cell death and DNA damage, Chinese …

    colostate Repository record for Evaluation of 64Cu-ATSM in cell culture for potential use as a radiotherapy agent (opens in a new tab)

  14. Components of detector response function : experiment and monte carlo simulations

    … considering escape/absorption of photons, photoelectrons, Auger electrons, recoil electrons and X-rays of the detector material. A detailed comparison of the experimental Compton, photoelectron, detector X-ray escape components and full-energy peaks with those obtained from Monte Carlo program …

    metu Repository record for Components of detector response function : experiment and monte carlo simulations (opens in a new tab)

  15. A Proof-of-Principle Investigation for a Neutron-Gamma Discrimination Technique in a Semiconductor Neutron Detector

    … rays with competing internal conversion (IC) electrons. Following the expulsion of conversion electrons from the atomic shells of 158Gd, the excitation energy of the atom is released through the emission of Auger electrons and characteristic x-rays. The low energy conversion electrons and …

    ohiolink Repository record for A Proof-of-Principle Investigation for a Neutron-Gamma Discrimination Technique in a Semiconductor Neutron Detector (opens in a new tab)

  16. AUGER ELECTRON SPECTROSCOPY OF CRYOGENIC MATRIX ISOLATED METAL ATOMS AND DIRECT RECOIL SPECTROSCOPY (DRS), SIMS AND XPS STUDIES ON TITANIUM AND PIQ

    Auger electron spectra of matrix-isolated metal atoms have been recorded for the first time. Differences in extra-atomic relaxation between bulk metal and argon matrix isolated atoms resulted in shifts in the energy of LMM Auger electrons, $-3.1$ eV for potassium and $-8.7$ eV for titanium. The sum …

    rice Repository record for AUGER ELECTRON SPECTROSCOPY OF CRYOGENIC MATRIX ISOLATED METAL ATOMS AND DIRECT RECOIL SPECTROSCOPY (DRS), SIMS AND XPS STUDIES ON TITANIUM AND PIQ (opens in a new tab)

  17. Binary Alloy Surfaces: Surface Segregation and the Effects of Ion Bombardment on the Surface Composition of Cr-Mo Alloys

    … surface analysis was performed using Auger Electron Spectroscopy. A major limitation to the accuracy attained was identified with differences in surface roughness between the alloy and elemental standards. An investigation was carried out to establish a correlation between sputtering, …

    mcmaster Repository record for Binary Alloy Surfaces: Surface Segregation and the Effects of Ion Bombardment on the Surface Composition of Cr-Mo Alloys (opens in a new tab)

  18. Development of a Physical, Chemical, and Biological Modeling Framework to Investigate Radiosensitization Effects of Gadolinium Nanoparticles Irradiated with Photons

    … simulations revealed the significant role of Auger electrons in dose enhancement at sub-micron distances, while chemical simulations highlighted molecular species dynamics and inter-track effects in lysosomes. Biological modeling identified concentration thresholds for radioenhancement, and in …

    qucosa-diss Repository record for Development of a Physical, Chemical, and Biological Modeling Framework to Investigate Radiosensitization Effects of Gadolinium Nanoparticles Irradiated with Photons (opens in a new tab)

  19. A systematic study of backward ejected electrons for 1 MeV/u O ℓ (q = 3 - 8) projectile ions colliding with argon gas

    … measurements of the energy distribution of electrons emitted into a cone of half angle Δθ = 2 ° centered at 0 = 180 ° with respect to the beam direction. The backward ejected electrons are produced in collisions between 1 MeV/u O<sup>q+</sup> [q = 3 - 8] projectile ions and argon atoms. A 30 …

    ut-knoxville Repository record for A systematic study of backward ejected electrons for 1 MeV/u O ℓ (q = 3 - 8) projectile ions colliding with argon gas (opens in a new tab)

  20. Kinematically complete study on electron impact ionisation of aligned hydrogen molecules

    … spatially aligned hydrogen molecules by 200 eV electrons was studied in a kinematically complete experiment. For the first time, a comprehensive set of fully differential cross sections (FDCS) was obtained for this process on a molecular target. The direction of the internuclear axis was derived …

    heid-diss Repository record for Kinematically complete study on electron impact ionisation of aligned hydrogen molecules (opens in a new tab)

Page 1 of 3