Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"Auto-Calibration"”.

  1. Auto-Calibration of WIM Using Traffic Stream Characteristics

    … the performance of Weigh-in-Motion (WIM) auto-calibration methods used by the Arkansas Department of Transportation (ARDOT). Typical auto-calibration algorithms compare the WIM measured weights of vehicles from the traffic stream to reference values, using five-axle tractor-trailer …

    arkansas Repository record for Auto-Calibration of WIM Using Traffic Stream Characteristics (opens in a new tab)

  2. Weigh-in-Motion Auto-Calibration Using Automatic Vehicle Identification

    … accurate data. After initial installation and calibration, WIM systems may experience measurement drifts in weight and axle detection. Recalibration takes two general forms: (a) On-site calibration involving running trucks of known weight over WIM scales and (b) Auto-calibration methods …

    arkansas Repository record for Weigh-in-Motion Auto-Calibration Using Automatic Vehicle Identification (opens in a new tab)

  3. Auto-Calibration and Control Applied to Electro-Hydraulic Poppet Valves

    … a general theoretical framework for online auto-calibration and control of general nonlinear systems is developed in this dissertation. This technique simultaneously learns the inverse input-state mapping (i.e. the calibration mapping) of the plant while forcing its state to follow a …

    gatech Repository record for Auto-Calibration and Control Applied to Electro-Hydraulic Poppet Valves (opens in a new tab)

  4. Auto -Calibration of Machine Tools Exploiting Redundancy, Transitivity, and Error Projection

    … allow the use of the augmented model in a larger calibration region without an added accuracy requirement to the measurement system. This work also investigates the possibility of using L infinity norm in addition to L2 norm in estimating errors and model parameters.

    uiuc Repository record for Auto -Calibration of Machine Tools Exploiting Redundancy, Transitivity, and Error Projection (opens in a new tab)

  5. Toward Auto-Calibration of Navigation Sensors for Miniature Autonomous Underwater Vehicles

    With an increase in the use of autonomous underwater vehicles (AUV's) comes the desire for smaller and cheaper AUV's. Reduction in size and cost will make AUV technology more accessible to research and industrial communities. These constraints also reduce the quality of components used in the …

    vt Repository record for Toward Auto-Calibration of Navigation Sensors for Miniature Autonomous Underwater Vehicles (opens in a new tab)

  6. An offset auto-calibration technique with cost-effective implementation for comparator and operational amplifier

    … comparator structure and describes an auto-calibration technique to systematically and significantly reducing the offset. The auto-calibration technique involves trimming of the comparator input transistor pair. Various trimming-switch structures are considered and compared, such as …

    iastate Repository record for An offset auto-calibration technique with cost-effective implementation for comparator and operational amplifier (opens in a new tab)

  7. A Deep Learning and Auto-Calibration Approach for Food Recognition and Calorie Estimation in Mobile e-Health

    … Machine (SVM). We propose a method for the fully automatic and user-friendly calibration of the sizes of food portions. This calibration is required to estimate the total number of calories in food portions. In this work, to compute the number of calories in the food object, we go beyond the …

    ottawa-retro Repository record for A Deep Learning and Auto-Calibration Approach for Food Recognition and Calorie Estimation in Mobile e-Health (opens in a new tab)

  8. Photometric stereo and appearance capture

    … taken under different lighting conditions. Auto-calibration photometric stereo methods recover surface shape and lighting directions at the same time. In this thesis, we propose two novel auto-calibration methods. One method exploits special ring-light configurations to resolve general …

    nus Repository record for Photometric stereo and appearance capture (opens in a new tab) Download file for Photometric stereo and appearance capture (opens in a new tab)

  9. A multi-configuration evaluation of the soil and water assessment tool (SWAT) in a mixed land use watershed in the central U.S.A.

    … than] 0.5, PBIAS [less than] 25%) without calibration. Watershed and soil resolution had negligible impact; climate input had considerable impact. Single climate station input is best used for applications requiring monthly predictions; distributed climate station input is needed for daily …

    missouri Repository record for A multi-configuration evaluation of the soil and water assessment tool (SWAT) in a mixed land use watershed in the central U.S.A. (opens in a new tab)

  10. Optimal Image-Aided Inertial Navigation

    … are The development of a structureless camera auto-calibration and system calibration algorithm for a GNSS, IMU and stereo camera system. The auto-calibration bundle adjustment utilizes the scale restraint equation, which is free of object coordinates. The number of parameters to be estimated …

    york Repository record for Optimal Image-Aided Inertial Navigation (opens in a new tab)

  11. Position Estimation Using Magnetic Fields

    … with stroke lengths of 5 cm and 10 cm. Next an auto-calibration system is developed in order to enable the sensor board to estimate position accurately when installed on new cylinders. Small misalignments and offsets in location can occur on each installation. The new auto-calibration method …

    umn Repository record for Position Estimation Using Magnetic Fields (opens in a new tab)

  12. Systems and Methods for Multiple-View and Depth-Based People Tracking and Human-Computer Interaction

    … touch points. Accurate intrinsic and extrinsic calibration of cameras and camera systems is essential for optimal data fusion and state estimation. Typically, calibration procedures are carried out manually, which is not only time-consuming but can also be impractical. To address this issue in …

    aalto Repository record for Systems and Methods for Multiple-View and Depth-Based People Tracking and Human-Computer Interaction (opens in a new tab)

  13. Avaliação do desempenho de um motor de combustão interna operando com etanol e adição de hidrogênio

    … computationally. To this end, a method for auto-calibration of combustion and heat transfer parameters was proposed and validated. This approach proved to be successful in predicting the pressure curve inside the cylinder and was then used in the lean operating regime. It was observed that …

    brazil-uerj Repository record for Avaliação do desempenho de um motor de combustão interna operando com etanol e adição de hidrogênio (opens in a new tab)

  14. Reliable Gait Analysis with Context-Aware Wearable Sensor Systems

    … ground-truth validation and repeated laboratory calibration are not always available.This study addresses these challenges by developing context-aware wearable sensing methods for reliable gait analysis during everyday activities. The proposed approaches use information about the user’s activity, …

    unh-thes Repository record for Reliable Gait Analysis with Context-Aware Wearable Sensor Systems (opens in a new tab)

  15. Direction finding in the presence of a more realistic environment model

    … array. To compensate for these errors pre-calibration and auto-calibration techniques are presented. The effects of real-ground constituent parameters on the mutual coupling (MC) of wire type antenna arrays for DOA estimation are investigated. This is accomplished by pre-calibration of the …

    mtu Repository record for Direction finding in the presence of a more realistic environment model (opens in a new tab)

  16. Modular GC: A Fully Integrated Micro Gas Chromatography System

    … Outlet µGC system. We have designed a novel auto-calibration method for temperature calibration of the microfabricated devices which does not require changing the electronic circuitry or reprogramming the device. The vacuum outlet µGC setup is tested with various mixture of analytes. For …

    vt Repository record for Modular GC: A Fully Integrated Micro Gas Chromatography System (opens in a new tab)

  17. Development of Novel Piezo-Driven Parallel-Kinematics Micropositioning Stages

    … addition to the development of the above stages, auto-calibration procedures and set-ups were proposed to allow these stages to be calibrated automatically and routinely using low-cost embedded calibration/sensing module. The mathematical validity of the procedures is proved by computer …

    uiuc Repository record for Development of Novel Piezo-Driven Parallel-Kinematics Micropositioning Stages (opens in a new tab)

  18. An AFE based embedded system for physiological computing

    … consumption increase with the constant need for calibration. For more than one century, the non‐invasive measurement of blood pressure has relied on the inflation of pneumatic cuffs around a limb. In addition to being occlusive and thus cumbersome, clinical cuff‐based methods, provide …

    uoit Repository record for An AFE based embedded system for physiological computing (opens in a new tab)

  19. Robust Estimation of Motion Parameters and Scene Geometry : Minimal Solvers and Convexification of Regularisers for Low-Rank Approximation

    In the dawning age of autonomous driving, accurate and robust tracking of vehicles is a quintessential part. This is inextricably linked with the problem of Simultaneous Localisation and Mapping (SLAM), in which one tries to determine the position of a vehicle relative to its surroundings without …

    lund Repository record for Robust Estimation of Motion Parameters and Scene Geometry : Minimal Solvers and Convexification of Regularisers for Low-Rank Approximation (opens in a new tab) Download PDF for Robust Estimation of Motion Parameters and Scene Geometry : Minimal Solvers and Convexification of Regularisers for Low-Rank Approximation (opens in a new tab)

  20. Ion-Selective Optical Sensors for the Management of Plant Nutrient Solutions

    … in sensors that offered the advantage of auto-calibration. The sensors met selectivity requirements in half strength Hoagland nutrient solution and provided repeatable measurements in solutions of different ion activity levels. Potassium and calcium selective membranes demonstrated …

    guelph Repository record for Ion-Selective Optical Sensors for the Management of Plant Nutrient Solutions (opens in a new tab)

Page 1 of 2