  1. Investigation of Adaptive Auto-Reclosing for Radial Distribution System with Distributed Energy Resources

    … in RDS are temporary in nature and require the auto-reclosing scheme to reduce the impact of such faults. Connecting two live electrical systems requires proper synchronization to avoid mechanical damage to generators. This thesis investigates an approach to have adaptive auto-reclosing in RDS …

    tamu Repository record for Investigation of Adaptive Auto-Reclosing for Radial Distribution System with Distributed Energy Resources (opens in a new tab)

  2. The improved use of auto-reclosing on overhead-lines in the Dutch high voltage grid

    … of this paper is to give more insight in which Auto-Reclosing (AR) methods, including smart AR methods, can be used in different parts of the Dutch High Voltage (HV) (110-380kV) grid regulated by TenneT TSO. Next to that the most appropriate AR method will be recommended for each of certain …

    eindhoven Repository record for The improved use of auto-reclosing on overhead-lines in the Dutch high voltage grid (opens in a new tab)

  3. Development of a model of the alpha/beta 765kV line for the evaluation of auto-reclosing.

    … preventing overvoltages from being caused during auto-reclosing. Other possible solutions of reclosing protection are investigated. It has been shown on two occasions, from actual field data that overvoltages have occurred on the lines after reclosing. High overvoltages on this network could be …

    ukzn Repository record for Development of a model of the alpha/beta 765kV line for the evaluation of auto-reclosing. (opens in a new tab)

  4. Development of a novel single-phase auto-reclosing scheme for distribution network with integrated distributed generation.

    … and disruption of the operation of conventional auto-reclosing schemes. However, with the continuous increase of penetration of DGs into existing distribution networks, it is becoming increasingly important that DGs must support power networks during steady-state and fault conditions. It has been …

    rgu Repository record for Development of a novel single-phase auto-reclosing scheme for distribution network with integrated distributed generation. (opens in a new tab)

  5. Modeling of Inverter-Based Resources for Hardware in the Loop Testing of Protection and Control Schemes

    … during transmission line circuit breaker auto-reclosing (AR). The research explores modern and adaptive protection and control schemes by leveraging digital substation technologies. Methodologically, the research focuses on developing IBR models within Electromagnetic Transient (EMT) …

    mtu Repository record for Modeling of Inverter-Based Resources for Hardware in the Loop Testing of Protection and Control Schemes (opens in a new tab)

  6. Power System Transient Diagnostics Based on Novel Traveling Wave Detection

    … In order to improve power systems stability, auto-reclosing (AR), single-phase auto-reclosing (SPAR), and adaptive single-phase auto-reclosing (ASPAR) methods have been developed with the final objectives of distinguishing between the transient and permanent faults to clear the transient …

    unr Repository record for Power System Transient Diagnostics Based on Novel Traveling Wave Detection (opens in a new tab)

  7. Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection

    … advanced protection functions such as adaptive automatic auto-reclosing and high-speed protection schemes. A protection device was modeled considering a sampling frequency equal to 1 MHz, including functions to detect traveling waves via wavelet transform, and the proposed protection algorithm …

    brazil-ufrn Repository record for Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection (opens in a new tab)

  8. Estudo de extinção de arco secundário no religamento monopolar de linhas de extra-alta tensão

    This work deals with single-phase auto reclosing in extra high voltage overhead transmission lines. The characteristics, limitations and main requirements for this switching operation are discussed. Among these requirements special attention is given to the extinction of the secondary electric arc, …

    brazil-ufmg Repository record for Estudo de extinção de arco secundário no religamento monopolar de linhas de extra-alta tensão (opens in a new tab)

  9. Développement d'une stratégie de protection pour réseaux HVDC à base de lignes aériennes et/ou hybrides

    … V. Le CHAPITRE VI traite de la refermeture automatique des lignes aériennes dans les réseaux MTDC et un nouveau concept de pré-excitation est proposé.