An experimental approach to Automatic Exposure Control testing.
… the functionality testing of the x-ray machine Automatic Exposure Control (AEC). The current NRL protocol for AEC testing is based on the radiographic film environment (NRL C5 1994). This protocol was tested to determine its applicability to the digital computed radiography (CR) imaging systems …
-
Non-parametric Methods for Automatic Exposure Control, Radiometric Calibration and Dynamic Range Compression
… phases of the imaging process, which are (i) ``Automatic exposure adjustment'' (ii) ``Radiometric calibration'' (iii) ''High dynamic range compression''. These contributions touch the initial, intermediate and final stages of imaging pipeline of digital cameras. For exposure control, we propose …
-
Development of a software based automatic exposure control system for use in image guided radiation therapy
… Systems, Inc., Palo Alto, CA) does not have an automatic exposure control system and therefore requires exposure factors to be manually selected. Without patient specific exposure factors, images may become saturated and require multiple unnecessary exposures. A software based automatic exposure …
-
Automatic Exposure Control During Computed Tomography Scans of the Head: Effects on Dose and Image Quality
Automatic exposure control (AEC) is effective at reducing potentially harmful radiation doses without sacrificing image quality for many types of computed tomography (CT) scans. However, there is a need for more information regarding the use of AEC for CT head scans. This study was conducted at …
-
Abgrenzbarkeit von mediastinalen und hilären Lymphknoten in der kontrastverstärkten Niedrigdosis-Computertomographie des Thorax
… retrospective (20 months) matched case–control study, two independent, blinded observers compared measurable lymph node delineation (yes–no) in six different International Association for the Study of Lung Cancer (IASLC) zones (upper mediastinal, aortopulmonary, subcarinal, lower …
-
Improving cone-beam CT image quality using non-circular orbits
… First, an acquisition workflow and a fully automatic online geometric calibration algorithm enable arbitrary non-circular orbits on clinical robotic C-arms with the speed, accuracy, and robustness required for the intraoperative workflow. The algorithm uses radio-opaque skin-marker fiducials …
-
Image Quality Optimisation and Dose Management in CT, SPECT/CT, and PET/CT
… PET, has raised concerns about patient radiation exposure and the consequent increased risk of malignancy later in life. The overall objective of this work was to evaluate and optimise different approaches for minimising patient radiation absorbed dose and maintaining or improving image quality in …
-
Assessment and optimisation of digital radiography systems for clinical use
… in applying such measurements to routine quality control and this project initially focuses on obtaining NPS and MTF results for 12 IDR systems in routine clinical use. Appropriate automatic exposure control (AEC) device calibration and a reproducible measurement method are key to optimising X-ray …
-
Optimisation of radiation dose and image quality for AP pelvis radiographic examination
… design. The optimisation includes manual and automatic exposure control modes. The image quality is visually assessed using the previously developed (novel) image quality scale and physically using a signal to noise ratio. The optimisation work is conducted with the aim of achieving two …
-
Advanced Techniques for Image Quality Assessment of Modern X-ray Computed Tomography Systems
… the single largest source of medical radiation exposure to the U.S. population. For this reason, there is a critical need to optimize CT examinations such that the dose is minimized while the quality of the CT images is not degraded. This optimization can be difficult to achieve due to the …
-
An investigation into methods for dose optimisation for paediatric AP pelvis projections when considering size variations
… age. Systematic variations (factorial design) of exposure factors (kVp, mAs, SID and additional filtration) were conducted to acquire AP pelvis X-ray images. Images for the 1 and 5-year-old phantom were acquired with manual exposure control. While the images for the 10-year-old were acquired with …
-
Quantitative assessment of image quality in digital breast tomosynthesis
… to phantom thickness increase is attributed to Automatic Exposure Control system of the specific mammographic unit.Regarding the results of MC cluster size on MC cluster SDNR in the uniform background part of the TORMAM phantom, inter comparison among mammographic modes, demonstrated DBT and 2D …