Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 76 for “"Automatic calibration"”.

  1. Automatic Calibration of Optical Multitouch Surfaces

    In this, thesis a novel system for automatically calibrating an optical multitouch surface is presented. The current state of multitouch software forces the user to manually calibrate a surface prior to usage. This process can be tedious and error prone, especially for large surfaces. Our system …

    regina Repository record for Automatic Calibration of Optical Multitouch Surfaces (opens in a new tab) Download PDF for Automatic Calibration of Optical Multitouch Surfaces (opens in a new tab)

  2. Automatic calibration of laser stripe bathymetric mapping systems

    … in pose estimates and in the modelling and calibration of sensors. While the former generalises across many problems and is the focus of much research, the latter are specific to the mapping system and application, and so are under explored for laser stripe mapping systems, particularly the …

    soton Download PDF for Automatic calibration of laser stripe bathymetric mapping systems (opens in a new tab)

  3. Sensitivity-based guided automatic calibration of hydrological models

    A new method for efficient calibration of complex hydrological models that combines Dynamically Dimensioned Search (DDS) global optimization algorithm with Global Sensitivity Analysis (GSA) methods is introduced. This approach, which is called sensitivity-informed DDS, utilizes sensitivity indices …

    manitoba Repository record for Sensitivity-based guided automatic calibration of hydrological models (opens in a new tab)

  4. Design and Automatic Calibration of Analog Filters for VLSI Applications

    … the voltage, temperature, and process variation, automatic tuning circuitry is required to maintain filter characteristics and improve the filter performance. This research proposes a new design method for a second-order tunable bandstop filter and a new technique to tune the center frequency, the …

    tamu Repository record for Design and Automatic Calibration of Analog Filters for VLSI Applications (opens in a new tab)

  5. Developing Efficient Strategies for Automatic Calibration of Computationally Intensive Environmental Models

    … the model is structured and calibrated. Model calibration is typically in an automated form where the simulation model is linked to a search mechanism (e.g., an optimization algorithm) such that the search mechanism iteratively generates many parameter sets (e.g., thousands of parameter sets) …

    waterloo Repository record for Developing Efficient Strategies for Automatic Calibration of Computationally Intensive Environmental Models (opens in a new tab)

  6. Automatic Calibration of Water Quality and Hydrodynamic Model (CE-QUAL-W2)

    … has drawn interest towards methods for automated calibration. This study addresses using an automatic technique to calibrate the water quality model CE-QUAL-W2 (Cole and Wells, 2013). CE-QUAL-W2 is a two-dimensional (2D) longitudinal/vertical hydrodynamic and water quality model for surface water …

    portland-state Repository record for Automatic Calibration of Water Quality and Hydrodynamic Model (CE-QUAL-W2) (opens in a new tab)

  7. Automatic Calibration of Storm Water Management Model (SWMM) with Multi-objective Optimization

    … parameters are practically impossible, so model calibration is a challenging task. Manual calibration is used mostly but requires significant efforts and stops once simulation results are “satisfactory”. Some studies have adopted automatic calibration using a single objective optimization. …

    buffalo Repository record for Automatic Calibration of Storm Water Management Model (SWMM) with Multi-objective Optimization (opens in a new tab)

  8. Developing a (Semi) Automatic Calibration Procedure for Cellular Automata based Land-use Models

    … to application, with a particular focus on calibration. Calibration of LUCA models is complex, as land-use change is a path-dependent process with uncertain outcomes captured by a number of model parameters. Of note are LUCA models that use a transition potential, which are traditionally …

    adelaide Repository record for Developing a (Semi) Automatic Calibration Procedure for Cellular Automata based Land-use Models (opens in a new tab)

  9. Automatic Calibration of Multiple Fisheye Cameras: Trajectory based Extrinsic Calibration of a Multicamera Rig

    This thesis presents a new technique for automatic extrinsic calibration of fisheye cameras on boats. In contrast to most of the existing methods that require overlapping field of view, our technique does not, which opens up for completely free placement of cameras. The method selected for this …

    chalmers Repository record for Automatic Calibration of Multiple Fisheye Cameras: Trajectory based Extrinsic Calibration of a Multicamera Rig (opens in a new tab)

  10. Mapping and Merging Using Sound and Vision : Automatic Calibration and Map Fusion with Statistical Deformations

    … of arrival (TDOA) measurements is referred to as automatic calibration. The corresponding process for images is to estimate the camera positions as well as the positions of the objects captured in the images. This is called structure from motion (SfM) or visual simultaneous localisation and …

    lund Repository record for Mapping and Merging Using Sound and Vision : Automatic Calibration and Map Fusion with Statistical Deformations (opens in a new tab) Download PDF for Mapping and Merging Using Sound and Vision : Automatic Calibration and Map Fusion with Statistical Deformations (opens in a new tab)

  11. Comparison Of Stochastic Radial Basis Function And Pest For Automatic Calibration Of Computationally Expensive Groundwater Models With Application To Miyun-Huai-Shun Aquifer

    … model largely depends on model parameters calibration, which is extremely computationally expensive. Therefore, it is highly desirable that efficient optimization algorithms be applied to automatic calibration problems. In this study, we compare the performance of three optimization …

    cornell Repository record for Comparison Of Stochastic Radial Basis Function And Pest For Automatic Calibration Of Computationally Expensive Groundwater Models With Application To Miyun-Huai-Shun Aquifer (opens in a new tab)

  12. Automatic calibration of a video camera lens system : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology in Information Engineering at Massey University

    An automated camera calibration procedure was successfully developed to allow accurate measurements to be made from images obtained from camera-lens systems exhibiting geometric and lens distortion. The calibration procedure is based upon image analysis methods programmed in script using Mathworks …

    massey Repository record for Automatic calibration of a video camera lens system : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology in Information Engineering at Massey University (opens in a new tab)

  13. Toward an automatic parallelized two-qubit-gate calibration

    … intervention must be reduced to a minimum and an automatic calibration must be developed to carry out all these complex calibrations. The quantum processor developed by the quantum computing group at Chalmers is already complex enough to require such automation, as it contains 25 qubits. The group …

    chalmers Repository record for Toward an automatic parallelized two-qubit-gate calibration (opens in a new tab)

  14. Calibração automática de modelos tipo chuva-vazão utilizando técnicas de suavização: uma aplicação ao modelo SMAP-II

    Parameter calibration is a critical, but essential step in Hydrologic Modelling. In this way, some optimization algorithms for automatic calibration have been applied to conceptual Rainfall-Runoff modelling, but several problems have been detected, which have motivated many researches. This work …

    brazil-uerj Repository record for Calibração automática de modelos tipo chuva-vazão utilizando técnicas de suavização: uma aplicação ao modelo SMAP-II (opens in a new tab)

  15. Development of a real-time algorithm for automation of the grain yield monitor calibration

    … algorithm defined specific bounds for the calibration period and estimated partial tank load weight, replacing the operator entered load weights from the prescribed manual calibration process. The automatic calibration system was integrated with the impact based yield monitor system, …

    iastate Repository record for Development of a real-time algorithm for automation of the grain yield monitor calibration (opens in a new tab)

  16. Análise e superação de algumas dificuldades na calibração automática do modelo SMAP-II - versão suavizada

    … there are parameters estimated by manual or automatic calibration. The calibration is one of the most difficult and arduous phases in the simulation process. This work analyses the difficulties encountered in the automatic calibration of the SMAP-II model, smoothing version. A possible …

    brazil-uerj Repository record for Análise e superação de algumas dificuldades na calibração automática do modelo SMAP-II - versão suavizada (opens in a new tab)

  17. The infrared absorption spectra of nitrogen dioxide

    An automatic calibration marker and wavelength scanning drive has been installed on the Perkin-Elmer infrared spectrometer and the precision of this drive was checked under various operating conditions. The optimum reproducibility was found to be 0.03 wave-drive divisions and the reproducibility …

    ubc Repository record for The infrared absorption spectra of nitrogen dioxide (opens in a new tab) Download PDF for The infrared absorption spectra of nitrogen dioxide (opens in a new tab)

Page 1 of 4