Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 10 of 10 for “"Auxiliary electrode"”.
-
Design and development of electrochemical gas sensors
… 20°C). (b) Very active fuel cell-type Pt black electrodes with large activity reserves giving rise to low span temperature coefficients, wide dynamic measurement ranges and enhanced long-term stability. (c) A close-wick sandwich arrangement of the electrodes conferring very good stability, to …
-
Design and fabrication of a MEMS micromirror with integrated charge sensor for feedback control
… development. The test structure includes the auxiliary electrode located directly on top of the lower drive electrode, to establish an integrated capacitor in order to make the desired charge measurement. This thesis concentrates on the manufacturability of such a device. Several fabrication …
-
Determination of iodide and iodate in aqueous solution
… iodate is reduced on a stainless steel working electrode with a platinum auxiliary electrode in acidic medium. Under optimized applied voltage, the electrochemical reduction current peak height is directly related to iodate concentration in the samples. This method has been successfully applied …
-
Non-Noble Metal Cathodic Electrocatalysts for PEM Fuel Cells and Direct Methanol Fuel Cells
… were then evaluated electrochemically in a three-electrode one-compartment cell, using a 0.5 M H2SO4 solution as electrolyte, an auxiliary electrode and a reversible hydrogen electrode (RHE), as counter and reference electrodes, respectively. X-ray photoelectron spectroscopy (XPS), X-ray …
-
Selectivity and detection in capillary electrophoresis
… the capsacinoids. Commercially available microelectrodes together with large 25 μm id fused silica capillary columns are used for the first time in the presence of an auxiliary electrode. Minimum detectable quantities and efficiencies are sample dependent and were found to be comparable to the …
-
Electrochemical biosensor array characterization
… configuration to the output signal strength. The electrodes are on the micron scale, and are capable of performing electrochemistry on living cells. The sensor sites were characterized using differential pulse voltammetry to find their relative performance. Based on these results, further tests …
-
Adsorção de Mn (II) e Zn (II) em soluções aquosas usando perlita expandida revestida com quitosana
… to quantify the adsorbed ions, and the working electrode glassy carbon, reference electrode silver / silver chloride and a platinum auxiliary electrode. The attainment of the peaks corresponding to ions Mn2+ and Zn2+ was evaluated in and electrochemical cell with a capacity of 30 mL using a …
-
Delivering Electrical and Mechanical Stimuli through Bioactive Fibers for Stem Cell Tissue Engineering
… the set-up was modified by incorporating an auxiliary electrode to focus the electric field. Highly aligned fibers with diameters ranging from 500 nm to 15 µm were fabricated from colorless polyimide (CP2) and polyglycolic acid (PGA) and used to construct multilayer scaffolds. This …
-
Μαθηματική μοντελοποίηση και βελτιστοποίηση τριοδικής λειτουργίας κυψελίδων καυσίμων
… results. The role of the geometry of anode and auxiliary electrode, as well as the role of carbon monoxide composition in the anodic feed stream and the fuel cell temperature during the triode operation were investigated. In addition, the triode operation was applied in a high temperature PEM …
-
Electrochemiluminescence devices based on Novel materials for Biosensors
… cost effective and environmental friendly electrode material for the detection of Ruthenium Tris Bypiridil (Ru(bpy)32+) using ElectroChemiLuminescence (ECL) technique. In this regard different novel materials, Carbon NanoTubes (CNT), Bismuth oxide (Bi2O3), Bismuth oxychloride (BiOCl), …