Computer simulation of rotating disc contactor
… in liquid-liquid extraction based on monodrop with/without considering the effects of solute transfer has been discussed by several investigators and has led to several correlations in specific conditions. Earhart (1975) and Wang (1980) used some of these correlations in the development …
-
Aspects of phase separation in an experimental mixer-settler using two solvent extraction systems
… the existence of double dispersions; that is, drops within drops. A photomicroscopic technique was used to undertake a drop size investigation of the dispersion produced with system 2. Drop size was found to be independent of dispersion throughput, a weak function of impellor speed and a …
-
Effect of emulsification parameters on the rheology, texture, and physical stability of cosmetic emulsions: a multiscale approach
… as well as the effect of these parameters on the average drop size and the drop size distribution at the microscopic scale. This study also considers the influence of the pumping capacity and tip velocity on the physical stability of cosmetic emulsions. Two dispersed phase concentrations were used …
-
Electrowet Coalescence Of Water Drops In Water-ULSD Dispersion
… during storage, transport and handling. Water drops of small size exist in ULSD mainly owing to the relatively low interfacial tension between the ULSD and water. It is necessary to filter out these water drops to avoid the problems of corrosion, decrease in engine performance and life, rust, …
-
Estudo da hidrodinâmica de uma coluna de extração Kühni
… hydrodynamics has been assessed regarding the average drop size, drop size distribution andhold-up (total and local). The following operational variables have been investigated: rotor speed (60, 90, 120, 150 and 180 rpm), flowrate of the dispersed phase (1.240 and 2.000 mL/min), flowrate of the …
-
Drop breakup in dilute Newtonian emulsions under steady shear
… video microscopy has been used to study drop breakup in dilute Newtonian emulsions under steady shear. Fundamental experimental studies on drop breakup have been limited to breakup in quiescent matrix or under pseudo-equilibrium conditions. This thesis represents the first direct …
-
Laboratory Test Program of Rotary Plate Sprinklers
… configure each sprinkler for application rate, average drop size and application area. The Midwest Plan Service publication Sprinkler Irrigation Systems (Scherer et al, 1999) lists factors to be considered in the selection of sprinkler packages for center pivot irrigation systems. The goal of …
-
Investigation into continuous spray and metered spray using compressed gas propellant
… in terms of spraying discharge rate and drop size through the packlife. Nevertheless, due to the nature of the compressed gas which contains significant level of moistures, as the main propellant, the applied sprays could inevitably be wetter with an increase dryness time which are not …
-
Investigation into continuous spray and metered spray using compressed gas propellant
… in terms of spraying discharge rate and drop size through the packlife. Nevertheless, due to the nature of the compressed gas which contains significant level of moistures, as the main propellant, the applied sprays could inevitably be wetter with an increase dryness time which are not …
-
Émulsions inverses très concentrées : formulation, comportement rhéologique et modélisation
Cette thèse concerne l’étude de l’influence de la formulation sur le comportement rhéologique des émulsions inverses très concentrées. Nous avons utilisé une démarche originale consistant à positionner le module élastique (G’) de ces émulions sur une carte bidimensionnelle formulation-composition, …