Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 50 for “"Average sensitivity"”.

  1. Machine Learning Approach to Predict Life-threatening Outcomes with Admit Electrocardiograms of Hospitalized Patients with COVID-19

    … ratio of 8:1:1. The prediction results yield an average sensitivity of 0.65 and an average specificity of 0.52 for all-cause mortality. For predicting life-threatening cardiovascular outcomes, it reaches an average sensitivity of 0.63 and an average specificity of 0.44.

    washington Repository record for Machine Learning Approach to Predict Life-threatening Outcomes with Admit Electrocardiograms of Hospitalized Patients with COVID-19 (opens in a new tab)

  2. Development of Single-Chip Silicon Photonic Microcantilever Arrays for Sensing Applications

    … nanomechanical sensing devices with high sensitivity. Two factors that affect the usefulness of microcantilevers in sensing scenarios are the sensitivity of the transduction method for measuring changes in microcantilever properties and the ability to create large compact arrays of …

    byu Repository record for Development of Single-Chip Silicon Photonic Microcantilever Arrays for Sensing Applications (opens in a new tab) Download PDF for Development of Single-Chip Silicon Photonic Microcantilever Arrays for Sensing Applications (opens in a new tab)

  3. Service identification and allocation in market-based power system operation

    … there are costs associated with each service, an average sensitivity allocation method was proposed in this research to allocate the amount and cost of services to various transmission users. It provides accurate allocation results when the services are second-order functions of the transactions. …

    iastate Repository record for Service identification and allocation in market-based power system operation (opens in a new tab)

  4. Analyzing massive datasets with missing entries: models and algorithms

    … missing edges. With this motivation, we define average sensitivity, a robustness metric for graph algorithms. We discuss various useful features of our definition and design approximation algorithms with good average sensitivity bounds for several optimization problems on graphs. We also define …

    bu Repository record for Analyzing massive datasets with missing entries: models and algorithms (opens in a new tab)

  5. Technical and Clinical Approaches for Implementing a Vision Screening Tool

    … screening cards using accuracy, specificity, sensitivity, and other statistical measures. Using QuickCheck’s best testing policy the application is currently able to detect subjects with any vision problems with an average sensitivity of 0.91 ± 0.11, although performance by eye is much lower …

    washington Repository record for Technical and Clinical Approaches for Implementing a Vision Screening Tool (opens in a new tab)

  6. Integration of Neonatal Mortality Prediction Models into a Clinical Decision Support System

    … mortality data (6% mortality rate) with the average sensitivity and specificity of 81% and 98% respectively. The mortality models were integrated with the PPADS tool to provide predictions about the risk of mortality for neonates admitted to the Neonatal Intensive Care Unit (NICU). The …

    carleton Repository record for Integration of Neonatal Mortality Prediction Models into a Clinical Decision Support System (opens in a new tab)

  7. CMOS Compatible 3-Axis Magnetic Field Sensor using Hall Effect Sensing

    … was designed, fabricated and tested with a sensitivity of 1.12x10-3 mV/Gauss using the RIT metal gate PMOS process. Poor geometry and insufficient design produced an offset voltage of 0.1238 volts in the 1-axis design; prevented sensing of the earth’s magnetic field. The new design features …

    rit Repository record for CMOS Compatible 3-Axis Magnetic Field Sensor using Hall Effect Sensing (opens in a new tab)

  8. Modelos baseados em redes neurais artificiais para o diagnóstico em triagem de tuberculose resistente e multirresistente no Brasil

    … Models developed by each State achieved an average sensitivity higher than 85% when screening RJ patients considering DR-TB from non DR-TB, against 82.7% using the national approach, indicating that the local clinical scores can better capture operational di erences present in the health …

    brazil-uerj Repository record for Modelos baseados em redes neurais artificiais para o diagnóstico em triagem de tuberculose resistente e multirresistente no Brasil (opens in a new tab)

  9. Exploring radiation induced lung toxicity with Raman spectroscopy

    … was classified with an accuracy up to 56%, average specificity of ∼85 and average sensitivity of ∼55% . To conclude, the development of a highly accurate spectroscopic-based method for classifying radiation induced pathology in murine lungs paves the way for future work in predicting …

    ubc Repository record for Exploring radiation induced lung toxicity with Raman spectroscopy (opens in a new tab) Download PDF for Exploring radiation induced lung toxicity with Raman spectroscopy (opens in a new tab)

  10. Alignments of Radio Source in the ELAIS N1 Deep Field

    … at α2000 = 16h10m35s and δ2000 = 54d35′ with an average angular resolution of 5” × 5” across the mosaic. The average sensitivity of the mosaicked image is 10μJy/beam in Stokes I. There were 65 extended radio galaxy jets extracted from the image of which 33 galaxies have redshift information …

    calgary Repository record for Alignments of Radio Source in the ELAIS N1 Deep Field (opens in a new tab)

  11. ECG Classification with an Adaptive Neuro-Fuzzy Inference System

    … The results from three trials indicate an average accuracy of 98.10%, average sensitivity of 94.99%, and average specificity of 98.87%. These results are comparable to two artificial neural network (ANN) algorithms: gradient descent and Levenberg Marquardt, as well as the ANFIS preprocessed …

    calpoly Repository record for ECG Classification with an Adaptive Neuro-Fuzzy Inference System (opens in a new tab)

  12. Fall detection system using low cost computing and online communication

    … system is highly reliable and accurate with the average sensitivity as 92.72 % and the average specificity as 95.9%, for a single person. Further research on improving the floor sensor data will also improve the results of fall detection system.

    missouri Repository record for Fall detection system using low cost computing and online communication (opens in a new tab)

  13. Sensitivity to Imperfections of Analog Quantum Simulation on Atomic Qudits

    … features of interest, such as chaos and hypersensitivity (quantum kicked top) and quantum phase transitions (the transverse Ising and Lipkin-Meshkov-Glick mod- els). Experimental simulations show high fidelity of the quantum state and dynamical features in the presence of native imperfections. …

    arizona-thes Repository record for Sensitivity to Imperfections of Analog Quantum Simulation on Atomic Qudits (opens in a new tab)

  14. Design and Calibration of a Novel High Temperature Heat Flux Sensor

    … (HFM) as the calibration standard. The measured sensitivity of the HTHFS was 20.4 ±2.0ìV/(W/cm2). The measured sensitivity value matched with the theoretically calculated value of 20.5 ìV/(W/cm2). The average sensitivity of the HTHFS prototype was one-fifth of the sensitivity of a commercially …

    vt Repository record for Design and Calibration of a Novel High Temperature Heat Flux Sensor (opens in a new tab)

  15. Analysing small-sample-sized methylation data to identify biomarkers for congenital heart defects

    … also for predicting CHDs by RF model, with an average sensitivity and specificity of 85% and 95%, respectively. This finding highlights that aberrant DNA methylation plays a significant role in the pathogenesis of CHDs, which may provide us with a potential approach in understanding CHDs. The …

    edithcowan Repository record for Analysing small-sample-sized methylation data to identify biomarkers for congenital heart defects (opens in a new tab)

  16. Spatial and temporal measurements using polyoxometalate, enzymatic and biofilm layers on a CMOS 0.35 μm 64 X 64-pixel I.S.F.E.T. array sensor

    … used. Our final measurements presented an average sensitivity of 30 mV/pH. With the addition of extra layers we were able to monitor a 65 mV voltage difference during our experiments with glucose and hexokinase, whereas a difference of 85 mV was detected for a similar glucose reaction …

    glasgow Download PDF for Spatial and temporal measurements using polyoxometalate, enzymatic and biofilm layers on a CMOS 0.35 μm 64 X 64-pixel I.S.F.E.T. array sensor (opens in a new tab)

  17. Laterally Movable Gate Field Effect Transistor (LMGFET) for microsensor and microactuator applications

    … type LMGFET structure are measured and show an average sensitivity Sl of - 4 µA/µm at drain to source voltage VDS of 10 V with the gate shorted to source. Several applications of microsystems utilizing LMGFET microstructures as a position sensor or an accelerometer, a spectrum analyzer or an …

    lsu-thes Repository record for Laterally Movable Gate Field Effect Transistor (LMGFET) for microsensor and microactuator applications (opens in a new tab)

  18. Prostate segmentation in ultrasound images using image warping and ellipsoid fitting

    … segmentation and area based metrics show average sensitivity and accuracy over 97% and 93% respectively. In 3D, i) the difference between manual and semi-automatic segmentation is on the order of interobserver variability, ii) the repeatability of the segmentation algorithm is consistently …

    ubc Repository record for Prostate segmentation in ultrasound images using image warping and ellipsoid fitting (opens in a new tab) Download PDF for Prostate segmentation in ultrasound images using image warping and ellipsoid fitting (opens in a new tab)

  19. A Multifunctional MEMS Pressure and Temperature Sensor for Harsh Environment Applications

    … at high temperatures is mainly caused by cross-sensitivity to temperature, which affects the pressure readout. In addition, the slow thermal response of temperature sensors used for such a dynamic application makes real-time sensing within a combustion engine very challenging. While numerous …

    waterloo Repository record for A Multifunctional MEMS Pressure and Temperature Sensor for Harsh Environment Applications (opens in a new tab)

  20. Nanostructured PVDF-TrFE based piezoelectric pressure sensors on catheter for cardiovascular applications

    … and flexible microsystems, with high sensitivity, fast recovery time, reduced form factor, for in situ blood pressure and flow monitoring with minimal invasiveness. Real-time endovascular pressure measurement techniques are crucial to evaluate the hemodynamics, which indicates the …

    texas Repository record for Nanostructured PVDF-TrFE based piezoelectric pressure sensors on catheter for cardiovascular applications (opens in a new tab)

Page 1 of 3