Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 34 for “"B-Mode Imaging"”
-
Fast and accurate transient ultrasound propagation and b-mode imaging simulation methods
… transient ultrasound wave propagation. B-mode imaging is widely used in practical diagnostic ultrasound applications. The imaging system is based on the pulse echo model. Transient ultrasound pulse waves are generated from the transducer, and echo signals are received to generate images. …
-
Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking
… overarching objective is to advance prediction models of human limb movements. These models enable improved control of actuated exoskeletons. The first contribution is a new method for the measurement of tendon properties *in vivo*. A protocol for the recording of ultrasonic B-mode videos of the …
-
Effects of Histotripsy on Bacterial Viability in Suspension
… by passive cavitation detection, plane-wave B-mode imaging and high-speed photography. Results showed that both regimens reduced E. coli counts significantly. Cavitation cloud size in shock-scattering histotripsy quantified by high-speed photography strongly predicted the E. coli inactivation. …
-
Clutter Noise Reduction in Ultrafast B-Mode Image
Ultrafast ultrasound imaging using plane waves has advanced a myriad of novel ultrasound imaging methods such as ultrafast contrast-enhanced imaging and shear wave elastography. However, due to the lack of transmission focusing and the beam steering operation in plane wave imaging (PWI), the …
-
Improving Prostate Cancer Detection using Multiparametric Ultrasound
… the prostate. In TRUS guided biopsy, the TRUS B-mode imaging is used by the clinician to ensure the biopsy needles remain within the prostate but is not sensitive nor specific enough to identify and target PCa-suspicious regions. Multiparametric magnetic resonance imaging (mpMRI) fusion biopsy is …
-
Η επίδραση της θρέψης στην επασβέστωση των καρδιακών βαλβίδων σε ασθενείς με τελικού σταδίου νεφρική ανεπάρκεια υπό εξωνεφρική κάθαρση
… by using two-dimensional echocardiography (B-mode imaging) in 42 stabilized patients aged 73 years on average, undergoing 4-hour hemodialysis 3 times a week in the kidney unit of the general hospital "Konstantopoulio Nea Ionia-Patision". Nutritional level of patients was assessed by using the …
-
Mathematically modeling the mechanical constants of thoracolumbar fascia under compression, in vivo
… studies. Recently, new advances in ultrasound imaging have made it possible to move towards measuring tissue strain. Since this is an in vivo method, mechanical data of tissues in their natural environment allows a more accurate representation of tissue strain. However, many different methods …
-
Πρώιμη διάγνωση εν τω βάθει φλεβικής θρόμβωσης: πρωτοκολλοποιημένη μελέτη με υπέρηχους ασθενών μονάδας εντατικής θεραπείας
… ultrasound study using the compression test in B-mode imaging (image to gray scale). The criterion for the absence or presence of a clot within the lumen was the presence or absence of full compressibility of the venous lumen, respectively. Intermittent compression was applied to multiple cross …
-
Transthoracic Cardiac Acoustic Radiation Force Impulse Imaging
… Acoustic Radiation Force Impulse (ARFI) imaging system to measure myocardial function non-invasively in clinical setting. Heart failure is an important cardiovascular disease and contributes to the leading cause of death for developed countries. Patients exhibiting heart failure with a …
-
Improved interface for deep venous thrombosis screening using B-mode ultrasound
… of deep venous thrombosis by processing B-mode ultrasound images, and by using information from additional force-torque and location sensors. It is known that deep venous thrombosis (DVT) is a disease that affects the venous system, where blood clots are formed and obstruct the venous …
-
Piezoelectric Micromachined Ultrasound Transducers for Medical Imaging
… alternative to conventional bulk-PZT thickness-mode transducers for high frequency, forward-looking, catheter-based ultrasound imaging of the cardiovascular system. The appeal of pMUTs is based on several key advantages over conventional transducer technologies, including high operational …
-
Targeting and characterisation of magnetic microbubbles for drug delivery using passive acoustic mapping
… cell experiments and <em>in vivo</em> mouse models. In tissue phantoms magnetic localisation of microbubble-induced cavitation activity was demonstrated and resolved using PAM. Under clinically relevant flow conditions an increase in the energy of cavitation on the order of 2-5 times was …
-
Development of a High Resolution Microvascular Imaging Toolkit for Optical Coherence Tomography
… development of new optical coherence tomography imaging systems and techniques to improve in vivo 3D microvascular imaging. Specifically these systems and techniques were proposed to address three main problems with 3D Doppler optical coherence tomography imaging: (a) Motion artefacts, (b) angle …
-
Temporal SNR Guided Adaptive B-mode and Color Doppler Transmit Parameter Selection
<p>Ultrasound is a dominant modality in medical imaging. The use of ultrasound continues to increase, and improved methods and new applications continue to be developed. Given the prevalence of ultrasound and its increasing use, streamlining scans, making imaging more straightforward for operators, …
-
Medical Ultrasound Imaging and Interventional Component (MUSiiC) Framework for Advanced Ultrasound Image-guided Therapy
Medical ultrasound (US) imaging is a popular and convenient medical imaging modality thanks to its mobility, non-ionizing radiation, ease-of-use, and real-time data acquisition. Conventional US brightness mode (B-Mode) is one type of diagnostic medical imaging modality that represents tissue …
-
Towards reliable machine learning for ultrasound screening of aortic stenosis
… practice. Although echocardiography with Doppler imaging is the clinical standard, these assessments are typically limited to trained specialists. Point-of-care ultrasound (POCUS) offers an accessible alternative for AS screening but is restricted to basic 2D B-mode imaging, often lacking the …
-
Potential for coded excitation to improve the detection of tissue and blood motion in medical ultrasound.
Doppler ultrasound imaging modalities arguably represent one of the most complex task performed (usually in real time) by ultrasound scanners. At the heart of these techniques lies the ability to detect and estimate soft tissues or blood motion within the human body. As they have become an …
-
Translation of Intravascular Optical Ultrasound Imaging
ances in the field of intravascular imaging have provided clinicians with power ful tools to aid in the assessment and treatment of vascular pathology. Optical Ultra sound (OpUS) is an emerging modality with the potential to offer significant bene fits over existing commercial technologies such as …
-
AI-Assisted Ultrasound-Guided High-Intensity Focused Ultrasound (USgHIFU) in Non-Invasive Surgery
… (PINN) integrated with a realistic breast model, breast tumors are targeted with high precision. The model utilizes a bowlshaped acoustic transducer to focus ultrasound waves directly on the tumor, achieving intense localized heating. The PINN method efficiently solves partial differential …
-
Robust Sonographic Muscle Quality Assessment: A Live, Accurate Tissue Speed-of-Sound Estimation Framework
… and operator assessment of the resulting B-mode images. Tissue speed-of-sound (SoS) can robustly augment muscle quality assessment as an intrinsic property of the tissue; however, sonographic measurement of muscle SoS is frequently limited by hardware which requires bilateral access to the …
Page 1 of 2