Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 365 for “"B-mode"”.

  1. Clutter Noise Reduction in Ultrafast B-Mode Image

    … (PWI), the presence of clutter noise on the B-mode image is unavoidable. The reduction of clutter noise is expected to increase the image contrast and spatial resolution, the two main criteria in ultrasound medical B-mode imaging for better diagnosis. Researchers have looked into this problem …

    whiterose Download PDF for Clutter Noise Reduction in Ultrafast B-Mode Image (opens in a new tab)

  2. Dekodér signálu ADS-B Mode-S pro přehledový radiolokátor

    ADS-B je mezinárodní standard pro sledování letadel a pozemních vozidel. Revize ADS-B DO-260C představuje zlepšení v několika oblastech, zejména lepší odolnost proti rušení. DO-260C využívá LDPC kanálové kódování. Cílem této práce je popsat ADS-B, LDPC kódy a poskytnout možné dekódovací algoritmy. …

    brno-tech Repository record for Dekodér signálu ADS-B Mode-S pro přehledový radiolokátor (opens in a new tab)

  3. Constraining Inflation Models with the BICEP/Keck B-mode Experiments

    Modern observational Cosmology is highly developed and the observable Universe on a large scale is currently well described by the standard LCDM model. The model has a small number of free parameters and describes how the Universe evolved from a hot, dense and homogeneous state with primordial …

    umn Repository record for Constraining Inflation Models with the BICEP/Keck B-mode Experiments (opens in a new tab)

  4. Improved interface for deep venous thrombosis screening using B-mode ultrasound

    … of deep venous thrombosis by processing B-mode ultrasound images, and by using information from additional force-torque and location sensors. It is known that deep venous thrombosis (DVT) is a disease that affects the venous system, where blood clots are formed and obstruct the venous …

    ubc Repository record for Improved interface for deep venous thrombosis screening using B-mode ultrasound (opens in a new tab) Download PDF for Improved interface for deep venous thrombosis screening using B-mode ultrasound (opens in a new tab)

  5. Temporal SNR Guided Adaptive B-mode and Color Doppler Transmit Parameter Selection

    … settings for one or both parameters during B-mode and color Doppler imaging without needing operator intervention. Frequency presents a tradeoff between data quality and imaging resolution. Acoustic output settings have a tradeoff between data quality and acoustic exposure levels. Acoustic …

    duke Repository record for Temporal SNR Guided Adaptive B-mode and Color Doppler Transmit Parameter Selection (opens in a new tab)

  6. Motion Estimation and Registration of B-Mode Ultrasound Images for Improved Visualisation

    This thesis presents a method for motion tracking between ultrasound images that originated from moving an ultrasound probe. The motion tracking is done in two steps: In the first step, a modified block-matching search is used to track the motion between frames by tracking the speckle and the …

    carleton Repository record for Motion Estimation and Registration of B-Mode Ultrasound Images for Improved Visualisation (opens in a new tab)

  7. Υπερηχογραφική απεικόνιση (b-mode) λιποϋπερτροφίας σε ινσουλινοθεραπευόμενους ασθενείς με διαβήτη (Βιβλιογραφική ανασκόπηση)

    … πριν γίνει ορατή και/ή ψηλαφητή. Το b-mode υπερηχογράφημα, καθιστά την πρώιμη διάγνωση εφικτή. Η απουσία κοινά αποδεκτών υπερηχογραφικών διαγνωστικών κριτηρίων λιποϋπερτροφίας δυσχεραίνουν την έρευνα, με πολλά κλινικά ερωτήματα να παραμένουν αναπάντητα. ΣΚΟΠΟΣ: Η βιβλιογραφική …

    athens Repository record for Υπερηχογραφική απεικόνιση (b-mode) λιποϋπερτροφίας σε ινσουλινοθεραπευόμενους ασθενείς με διαβήτη (Βιβλιογραφική ανασκόπηση) (opens in a new tab)

  8. Risk Factors in using B-mode High-resolution Measurement of Common Carotid

    … 전까지는 진단이 쉽지 않다. 혈관의 변화를 조기에 진단하기 위한 선별 검사로 B-mode 초음파를 이용한 경동맥 내막-중막의 두께(Intima-Media Thickness, IMT)의 측정이 좋은 방법으로 알려져 있다. 따라서 본 연구는 2005년 1월부터 2005년 9월까지 A대학병원에서 IMT를 측정한 16∼81세 400명의 내원자를 대상으로 B-mode 초음파를 사용하여 경동맥에서 IMT를 측정하였고, 일반적 특성, 건강행위, 가족력 및 질병력, 임상화학적 특성이 IMT에 영향을 미치는 요인을 파악하고자 하였다. …

    ajou Repository record for Risk Factors in using B-mode High-resolution Measurement of Common Carotid (opens in a new tab) Embargoed until 9999-12-31

  9. Evaluation of null subtraction imaging and interpolation techniques for ultrasound B-mode

    In biomedical ultrasound imaging, many attempts have been made to improve the lateral resolution through various adaptive and non-adaptive techniques. While each technique has its advantages and disadvantages, there are some challenges common to all methods. In particular, improvements in lateral …

    uiuc Repository record for Evaluation of null subtraction imaging and interpolation techniques for ultrasound B-mode (opens in a new tab)

  10. Fast and accurate transient ultrasound propagation and b-mode imaging simulation methods

    … transient ultrasound wave propagation. B-mode imaging is widely used in practical diagnostic ultrasound applications. The imaging system is based on the pulse echo model. Transient ultrasound pulse waves are generated from the transducer, and echo signals are received to generate images. …

    msu Repository record for Fast and accurate transient ultrasound propagation and b-mode imaging simulation methods (opens in a new tab)

  11. Automated Fatty Liver Disease Detection in Point-of-Care Ultrasound B-mode Images

    … acquired point-of-care-ultrasound (POCUS) B-mode images for the development of an automated classification algorithm for steatosis, the first NAFLD stage. A U-Net deep learning (DL) model is used for liver segmentation, followed by patch extraction, and DL-based classifiers. Average …

    guelph Repository record for Automated Fatty Liver Disease Detection in Point-of-Care Ultrasound B-mode Images (opens in a new tab)

  12. Utilization Of B-Mode Ultrasound As A Body Fat Estimate In Collegiate Football Players

    … and the three compartment-water (3C-W) model of Siri (1961), using Bioimpedance spectroscopy (BIS) to estimate total body water (TBW) and air-displacement plethysmography (BODPOD®) to determine body density (Db). Pearson’s product-moment correlation analyses were run to determine between …

    gsu Repository record for Utilization Of B-Mode Ultrasound As A Body Fat Estimate In Collegiate Football Players (opens in a new tab)

  13. Challenging $\Lambda$CDM: unraveling cosmic distances, dark sector phenomenology, and alternative primordial B-mode sources

    … Lambda Cold Dark Matter (LCDM) cosmological model, while remarkably successful, increasingly shows signs that it may not fully describe our Universe, as persistent tensions in expansion rates and structure formation remain unresolved. In this thesis, I challenge the LCDM paradigm using novel …

    unm Repository record for Challenging $\Lambda$CDM: unraveling cosmic distances, dark sector phenomenology, and alternative primordial B-mode sources (opens in a new tab)

  14. Real-time B-mode ultrasound image simulation and artifacts modelling of needles and brachytherapy seeds

    … simulators that synthesize realistic-looking B-mode images of tissue and interventional tools, such as the needle. For a prostate brachytherapy simulator in particular, both the needle and seed images need to be synthesized. In this thesis, we propose an interpolation-based method for simulating …

    ubc Repository record for Real-time B-mode ultrasound image simulation and artifacts modelling of needles and brachytherapy seeds (opens in a new tab) Download PDF for Real-time B-mode ultrasound image simulation and artifacts modelling of needles and brachytherapy seeds (opens in a new tab)

  15. Polarization Angle Calibration And B-Mode Characterization With The Bicep And Keck Array CMB Telescopes

    … waves that could imprint a detectable B-mode (curl-like) signal in the polarization of the CMB. It is this signal that the family of telescopes used by the BICEP1, BICEP2, and Keck Array collaborations were designed to detect. These telescopes are small aperture, on-axis, refracting …

    umn Repository record for Polarization Angle Calibration And B-Mode Characterization With The Bicep And Keck Array CMB Telescopes (opens in a new tab)

  16. Deep learning-based M-mode OCT system and B-mode OCT system diagnosis accuracy comparison

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-10-19 without embargo terms

    uiuc Repository record for Deep learning-based M-mode OCT system and B-mode OCT system diagnosis accuracy comparison (opens in a new tab)

  17. Validation of B-Mode Ultrasound Imaging as a Body Composition Measurement in Division I Football Players

    … the current study was to validate the use of B-mode ultrasound as a method to estimate body composition in Division I football players. Body composition was estimated using ultrasound, 7-site skinfold and a 4 compartmental model (4C) using Bioimpedance spectroscopy (BIS) to estimate total body …

    gsu Repository record for Validation of B-Mode Ultrasound Imaging as a Body Composition Measurement in Division I Football Players (opens in a new tab)

Page 1 of 19