Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 4 of 4 for “"B0 Shimming"”.

  1. A Combined, Fine-Tune B0 Shimming and RF Receive Array using Transmission Line Resonators for Functional Imaging of the Human Temporal Lobe at 7 Tesla

    … use of either fully external shim arrays, or shimming circuity integrated within standard array technology. Here, the use of transmission line resonators (TLRs) is proposed for use as a combined receive-only/B0 shimming element for imaging and local shimming of the ventral temporal lobe. …

    umn Repository record for A Combined, Fine-Tune B0 Shimming and RF Receive Array using Transmission Line Resonators for Functional Imaging of the Human Temporal Lobe at 7 Tesla (opens in a new tab)

  2. The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging

    … integrated parallel reception, excitation, and shimming (iPRES-W) coil design, is further developed to remove some of these wired connections by offering a compact and easy-to-integrate MR-compatible wireless data transfer solution, which requires no scanner modifications or additional antenna …

    duke Repository record for The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging (opens in a new tab)

  3. Methods for Homogenization of Spatio-Temporal B\(_0\) Magnetic Field Variations in Cardiac MRI at Ultra-High Field Strength

    … mechanisms, but suffers from spatio-temporal B0 magnetic field variations. Due to the resulting spatial misregistration and intra-voxel dephasing, these B0-field inhomogeneities generate a variety of undesired image artifacts, e.g., artificial image deformation. The resulting macroscopic field …

    wurz-thes Repository record for Methods for Homogenization of Spatio-Temporal B\(_0\) Magnetic Field Variations in Cardiac MRI at Ultra-High Field Strength (opens in a new tab)

  4. Parametrische suszeptibilitätsgewichtete Bildgebung des Myokards mittels Magnetresonanzbildgebung bei hohen Magnetfeldern

    … einer Studie mit gesunden Probanden werden zudem B0 Shimming Techniken angewendet um makroskopische Feldinhomogenitäten zu reduzieren und dadurch die Suszeptibiltätsempfindlichkeit gegenüber mikroskopischen Effekten zu verstärken. Diese Arbeit liefert erste in-vivo Normwerte für T2* Zeiten im …

    fu-berlin Repository record for Parametrische suszeptibilitätsgewichtete Bildgebung des Myokards mittels Magnetresonanzbildgebung bei hohen Magnetfeldern (opens in a new tab)