Results 1 to 16 of 16 for “"B1+-mapping"”
-
B1 Mapping for Magnetic Resonance Imaging
… and developing new methods of radiofrequency (B1) field mapping to improve quantitative MRI measures. The dissertation opens with an introduction and a brief primer on MRI physics, followed by an introduction to B1 and flip-angle mapping in MRI (Chapters 1-3). Chapter 4 presents a careful …
-
B1+-mapping and B1+ inhomogeneity correction at high field
… At such wavelength, the transmit magnetic field B1+ used to manipulate the magnetization in MR imaging is subject to constructive and destructive interferences and becomes position dependent. This inhomogeneity in the B1+ field leads to signal and contrast variations in the anatomical images …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Design of multidimensional radiofrequency pulses in magnetic resonance imaging
… (FOV) imaging of region-of-interest (ROI), B1 inhomogeneity correction, and simultaneous spatial-spectral selective excitation. While an elegant method known as Shinnar-Le Roux (SLR) method has been developed in one-dimensional RF pulse design, multidimensional RF pulse design remains an …
-
Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System.
… However, at ultrahigh field, severe transmit B1 (B1+) inhomogeneity occurs, limiting applications of most conventional MR techniques. Multidimensional spatially selective RF pulses have been proposed as a method to mitigate B1+ inhomogeneity. However, those RF pulses are typically very long …
-
Development and optimisation of high-field MRI techniques
… MR scanner and on a small bore 2.35T scanner: B1 becomes increasingly inhomogeneous at high fields resulting in image contrast non-uniformity. Compensation techniques greatly benefit from accurate B1 maps. A novel EPI-based B1 mapping method was implemented that is faster than pre-existing …
-
Three-dimensional T1 quantification techniques for assessment of cartilage quality using dGEMRIC
… shown that the main obstacles are related to B1 variations within the volume. As part of the work a 3D Look-Locker (3D-LL) T1 quantification pulse sequence have been created. In addition, new methods were developed for correction of B1 inhomogeneities and slab profile flip angle variations in …
-
Parallel transmission technologies for imaging the brain and body with 7 tesla MRI
… must first be mapped in a process known as “B1+ mapping”.</p> <p>To begin, I will go through some essential magnetic resonance physics and cover some of the key concepts used in this thesis. I will then introduce ultra-high field magnetic resonance imaging and discuss why it is of interest …
-
\(^{19}F\) Magnetresonanztomographie zur Bildgebung von Infektionen im Zeitverlauf
… entsprechend im Kapitel 4 \(Bloch-Siegert B_1^+-Mapping\) näher addressiert. Der Schwerpunkt liegt hierbei, wie der Kapitelname bereits andeutet, auf der Bloch-Siegert Methode, die insbesondere in der präsentierten Implementierung in einer Turbo/ Multi Spin Echo Sequenz eine effiziente Nutzung …
-
Advanced methodologies for neuromodulation and quantitative MRI with MB-SWIFT
… simultaneous quantitative T1 and T1?, or T1 and B1 3D MRI mapping. Look-Locker scheme that alternates magnetization from the laboratory frame’s +Z and -Z axes is combined with a 3D MB-SWIFT readout. The analytical solution describing the spin evolution during aLL and the correction required for …
-
Fast Absolute Quantification of In Vivo Water and Fat Content with Magnetic Resonance Imaging
… fat mass density can be computed, assuming the B1+ (transmit) and B1- (receive) fields can be measured. Phantom experiments with known water fat concentration were conducted to validate the feasibility of proposed method and in vivo data was collected from healthy volunteers. Results show good …
-
Mapping the Flip Angle in Magnetic Resonance Imaging Using the Accelerated 3D Look-Locker Sequence
… and above. In this thesis, a new technique for mapping the flip angle in 3D will be introduced. This technique is based on a highly time efficient T1 mapping technique, known as Look-Locker, which was adapted to map the flip angle using either a double angle (DALL) or dual repetition time (DτLL) …
-
Development and Application of Quantitative MRI Processing Tools to Track Structural and Functional Changes along the Neuraxis Following Spinal Cord Injury
… of the radio-frequency transmit field (B1+) inhomogeneities bias, which necessitates additional B1+ mapping. However, the effect of B1+ inhomogeneities on g-ratio maps is not known, and it is uncertain if an error and bias can be reduced by implementing a data-driven approach …