Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"B1 mapping"”.
-
B1 Mapping for Magnetic Resonance Imaging
… and developing new methods of radiofrequency (B1) field mapping to improve quantitative MRI measures. The dissertation opens with an introduction and a brief primer on MRI physics, followed by an introduction to B1 and flip-angle mapping in MRI (Chapters 1-3). Chapter 4 presents a careful …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI
… comes with its own set of challenges, with the B1 field being one of the significant hurdles. This dissertation presents a variety of alternate approaches to gathering a better understanding of the B1 field. At ultrahigh frequencies, i.e., those equal to or above 300 MHz for 1H, B1 field …
-
Design of multidimensional radiofrequency pulses in magnetic resonance imaging
… (FOV) imaging of region-of-interest (ROI), B1 inhomogeneity correction, and simultaneous spatial-spectral selective excitation. While an elegant method known as Shinnar-Le Roux (SLR) method has been developed in one-dimensional RF pulse design, multidimensional RF pulse design remains an …
-
Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System.
… However, at ultrahigh field, severe transmit B1 (B1+) inhomogeneity occurs, limiting applications of most conventional MR techniques. Multidimensional spatially selective RF pulses have been proposed as a method to mitigate B1+ inhomogeneity. However, those RF pulses are typically very long …
-
Three-dimensional T1 quantification techniques for assessment of cartilage quality using dGEMRIC
… shown that the main obstacles are related to B1 variations within the volume. As part of the work a 3D Look-Locker (3D-LL) T1 quantification pulse sequence have been created. In addition, new methods were developed for correction of B1 inhomogeneities and slab profile flip angle variations in …
-
Parallel transmission technologies for imaging the brain and body with 7 tesla MRI
… must first be mapped in a process known as “B1+ mapping”.</p> <p>To begin, I will go through some essential magnetic resonance physics and cover some of the key concepts used in this thesis. I will then introduce ultra-high field magnetic resonance imaging and discuss why it is of interest …
-
\(^{19}F\) Magnetresonanztomographie zur Bildgebung von Infektionen im Zeitverlauf
… entsprechend im Kapitel 4 \(Bloch-Siegert B_1^+-Mapping\) näher addressiert. Der Schwerpunkt liegt hierbei, wie der Kapitelname bereits andeutet, auf der Bloch-Siegert Methode, die insbesondere in der präsentierten Implementierung in einer Turbo/ Multi Spin Echo Sequenz eine effiziente Nutzung …
-
Advanced methodologies for neuromodulation and quantitative MRI with MB-SWIFT
… simultaneous quantitative T1 and T1?, or T1 and B1 3D MRI mapping. Look-Locker scheme that alternates magnetization from the laboratory frame’s +Z and -Z axes is combined with a 3D MB-SWIFT readout. The analytical solution describing the spin evolution during aLL and the correction required for …
-
Development and Application of Quantitative MRI Processing Tools to Track Structural and Functional Changes along the Neuraxis Following Spinal Cord Injury
… of the radio-frequency transmit field (B1+) inhomogeneities bias, which necessitates additional B1+ mapping. However, the effect of B1+ inhomogeneities on g-ratio maps is not known, and it is uncertain if an error and bias can be reduced by implementing a data-driven approach …