Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"BEVAR"”.

  1. Hospital Incidence, Treatment, and Outcome of 885 Patients with Thoracoabdominal Aortic Aneurysms Treated in Switzerland over 10 Years—A Secondary Analysis of Swiss DRG Data

    … and branched endovascular aortic repair (f/bEVAR), the surgical management of thoraco-abdominal aortic aneurysms (TAAAs) remains a major challenge. The aim of this study was to analyse the hospital incidence and hospital mortality of patients treated for TAAAs in Switzerland. Secondary data …

    zurich Repository record for Hospital Incidence, Treatment, and Outcome of 885 Patients with Thoracoabdominal Aortic Aneurysms Treated in Switzerland over 10 Years—A Secondary Analysis of Swiss DRG Data (opens in a new tab) Restricted access

  2. Endoleak Ic following fenestrated and branched EVAR

    … Τα τελευταία χρόνια, η ανάπτυξη των FEVAR και BEVAR επέτρεψε τη θεραπεία ενός ευρέος φάσματος παθήσεων της αορτής, συμπεριλαμβανομένων των παρανεφρικών και υπερνεφρικών ανευρυσμάτων, ανευρυσμάτων θωρακικής αορτής και της νόσου του διαχωρισμού. Αυτές οι εξελίξεις στην ενδοαγγειακή χειρουργική …

    athens Repository record for Endoleak Ic following fenestrated and branched EVAR (opens in a new tab)

  3. Literature review of thoracoabdominal aortic aneurysm endovascular treatment clinical trials /

    … of less invasive endovascular repair. FEVAR and BEVAR are now used as important treatment options, especially in patients with high operative risk. This narrative literature review analyzed the current evidence on endovascular repair of TAAA. PubMed, Cochrane Library, and ClinicalTrials.gov were …

    vilnius Repository record for Literature review of thoracoabdominal aortic aneurysm endovascular treatment clinical trials / (opens in a new tab)

  4. Use of fenestrated/branched endovascular devices for rescue of proximal endograft failure after infrarenal endovascular aneurysm repair - a systematic review of the literature and an updated meta-analysis

    … με θυριδωτό/κλαδωτό ενδομόσχευμα (F/BEVAR) σε προηγούμενη ενδαγγειακή αποκατάσταση με ενδομόσχευμα (EVAR) που δεν διατηρεί σφράγιση κεντρικά. Υλικά και Μέθοδοι: Διεξήχθη συστηματική ανασκόπηση της βιβλιογραφίας με βάση τις κατευθυντήριες οδηγίες PRISMA μέχρι και το Σεπτέμβριο του …

    athens Repository record for Use of fenestrated/branched endovascular devices for rescue of proximal endograft failure after infrarenal endovascular aneurysm repair - a systematic review of the literature and an updated meta-analysis (opens in a new tab)

  5. Infection after endovascular repair of complex aortic and thoracoabdominal aneurysms with fenestrated and branched devices

    … για λοίμωξη μοσχεύματος σε συσκευές F/BEVAR, εκ των οποίων οι 9 (64.2%) ήταν άνδρες. Η μέση ηλικία των ασθενών ήταν 74± 6 έτη. Οι τύποι μοσχευμάτων που χρησιμοποιήθηκαν στις επεμβάσεις ήταν 7 συσκευές FEVAR (50%) και 7 συσκευές F/BEVAR (50%). Θετικές καλλιέργειες ελήφθησαν σε 13 …

    athens Repository record for Infection after endovascular repair of complex aortic and thoracoabdominal aneurysms with fenestrated and branched devices (opens in a new tab)

  6. Neue Stent-Graft-Designs in der Behandlung von thorakalen, thorakoabdominellen und abdominellen Aortenaneurysmen

    Die endovaskuläre Versorgung von Aortenaneurysmen hat sich in den letzten zwei Dekaden zunehmend als Therapie der ersten Wahl durchgesetzt. Offen operative Verfahren kommen gegenwärtig vor allem dann zum Einsatz, wenn die Patientenanatomie eine angemessene endovaskuläre Therapie einschränkt. Neue …

    fu-berlin Repository record for Neue Stent-Graft-Designs in der Behandlung von thorakalen, thorakoabdominellen und abdominellen Aortenaneurysmen (opens in a new tab)