  1. Biosensor-based studies on coumarins

    … 7- hydroxycoumarin which was carried out on the BIAcore, an optical biosensor based on the phenomenon of surface plasmon resonance (SPR). The immunoassay was optimised and internally validated. Monoclonal antibodies were generated by somatic cell fusion using the spleens of mice immunised with a …

    dcu Repository record for Biosensor-based studies on coumarins (opens in a new tab)

  2. Immunoassays for the detection of illicit drugs and organophosphate pesticides

    … in a competitive ELISA format and on the BIAcore (a surface plasmon resonance based optical biosensor capable of monitoring biomolecular interactions in ‘real-time’). Combinatorial single chain Fv (scFv) antibody phage display libraries were also generated to morphine-3-glucuromde …

    dcu Repository record for Immunoassays for the detection of illicit drugs and organophosphate pesticides (opens in a new tab)

  3. Development of antibody-based assays for the detection of aflatoxins and organophosphates

    … in a surface plasmon resonance-based biosensor (BIAcore), which measures biomolecular interactions in ‘real-time’. Production of hapten-protein conjugates of the organophosphate pesticides chlorpyrifos and pirimiphos, and characterisation of antichlorpyrifos antibodies were also successfully …

    dcu Repository record for Development of antibody-based assays for the detection of aflatoxins and organophosphates (opens in a new tab)

  4. BINDING STUDIES OF EPIDERMAL GROWTH FACTOR RECEPTOR TARGETED COMPOUNDS USING SURFACE PLASMON RESONANCE

    … used Surface Plasmon Resonance (SPR) technology (Biacore) to study the binding kinetics of the antibodies EGF, Cetuximab and a candidate drug P-13 with the receptor EGFR. The candidate drug P-13 was synthesized and tested on Biacore for binding kinetics. This peptide is anticipated to bind to …

    vcu Repository record for BINDING STUDIES OF EPIDERMAL GROWTH FACTOR RECEPTOR TARGETED COMPOUNDS USING SURFACE PLASMON RESONANCE (opens in a new tab)

  5. Molecular Studies on the Interaction of Leptin With Its Receptor

    … a variety of biophysical techniques, namely BiaCore and microcalorimetry. To achieve this, it was necessary to express the leptin receptor. Because the receptor cDNA was not available at the start of this project, the initial goal was to obtain the cDNA encoding the extracellular domain of …

    glasgow Repository record for Molecular Studies on the Interaction of Leptin With Its Receptor (opens in a new tab)

  6. Sequential injection analysis for the investigation of biomolecular interactions

    … immobilized ligant. The commercially available BIAcore instrument, which uses surface plasmon resonance to evaluate biomolecular interactions, represents the standard in biosensor instrumentation. Therefore, comparison is made between results from BIAcore and those obtained with the SIB system. …

    washington Repository record for Sequential injection analysis for the investigation of biomolecular interactions (opens in a new tab)

  7. Antibody-based biosensor assays for the detection of zilpaterol and markers for prostate cancer

    … in a competitive ELISA format and on the Biacore (a surface plasmon resonance-based optical biosensor capable of monitoring biomolecular interactions in 'real-time'). A zilpaterol-HSA conjugate was used to generate and characterise single chain antibody fragments. A combinatorial single …

    dcu Repository record for Antibody-based biosensor assays for the detection of zilpaterol and markers for prostate cancer (opens in a new tab)

  8. Synthese von Cluster-Mannosiden als multivalente Inhibitoren für den Mannose-spezifischen Makrophagen-Rezeptor

    … und mittels Oberflächenplasmonenresonanz (SPR, Biacore), ELISA und Mikrokalorimetrie bezüglich ihrer biologischen Aktivität untersucht. Das MMR-Protein konnte durch Kultivierung von CHO-Zellen und Aufreinigung des Proteins aus dem Kulturmedium mittels Affinitätschromatographie isoliert werden.

    cau-kiel Repository record for Synthese von Cluster-Mannosiden als multivalente Inhibitoren für den Mannose-spezifischen Makrophagen-Rezeptor (opens in a new tab)

  9. Signalbindung und Membraninteraktion von heterotetrameren Adaptorprotein-Komplexen

    … mittels Oberflächenplasmonresonanz-Analyse (Biacore) in vitro untersucht. Alle getesteten Signale interagierten kaum mit AP4, aber gut mit AP3. Die Bindung an AP1 und AP2 war deutlich heterogener. Am auffälligsten dabei war, dass die lysosomalen Proteine LAMP-1 und LAMP-2B gut an AP1 banden, …

    goettingen Repository record for Signalbindung und Membraninteraktion von heterotetrameren Adaptorprotein-Komplexen (opens in a new tab)

  10. Microarray format for multi-parameter blood group serology

    … detection system, we have exploited the Biacore system as a recognised platform for real-time interaction studies. Although this system is not designed for the high throughput applications needed in blood testing, in this study it provided detailed information on the interactions between …

    edinburgh Repository record for Microarray format for multi-parameter blood group serology (opens in a new tab)

  11. Rapid methods for the detection of anti-protozoan drug residues.

    … enzyme-linked immunosorbent assay (ELISA) and Biacore assay formats that were applied successfully for the detection of halofuginone in ‘spiked’ egg samples. Immune phage display libraries were constructed and screened for diclazuril using a number of diclazuril-conjugates. A functional …

    dcu Repository record for Rapid methods for the detection of anti-protozoan drug residues. (opens in a new tab)

  12. Novel anitbody-based assays for disease and food contaminant detection

    … and subsequently used in an indirect ELISA and Biacore assay for the detection of antibodies to C. pseudotliberculosis in sheep serum samples. These assays were optimised using a variety of positive and negative controls and were then applied to a range of clinical samples from Irish herds. A …

    dcu Repository record for Novel anitbody-based assays for disease and food contaminant detection (opens in a new tab)

  13. The development and applications of polyclonal and monoclonal antibodies for the detection of illicit drugs in saliva samples

    … The antibodies were applied to a biosensor (BIAcore) assay for the detection of amphetamine and methamphetamine in saliva samples. The affinity constants for the antibodies were determined by ELISA and BIAcore methods. The values obtained were found to be similar by both methods. A novel …

    dcu Repository record for The development and applications of polyclonal and monoclonal antibodies for the detection of illicit drugs in saliva samples (opens in a new tab)

  14. Aptamers to the hepatitis C virus polymerase

    … Ten rounds of selection were performed using a Biacore 2000 and resultant aptamers cloned from rounds 2, 4, 8 and 10. Sequences of aptamers were aligned to elucidate common motifs and a proportion of the aptamers from rounds 8 and 10 (29/48) were screened for binding ability using the Biacore. …

    unsw Repository record for Aptamers to the hepatitis C virus polymerase (opens in a new tab)

  15. Structural and functional interactions between measles virus nucleocapsid protein and cellular heat shock protein

    … time using surface plasmon resonance technology (BIAcore). These same mutations, when incorporated into the N protein of recombinant infectious virus, also abrogate Hsp72-dependent infection phenotypes. Incorporation of a non-functional Hsp72 binding motif reduced the stimulatory effect of …

    ohiolink Repository record for Structural and functional interactions between measles virus nucleocapsid protein and cellular heat shock protein (opens in a new tab)

  16. Using a biosensor platform for the detection and characterization of autoantibodies in myasthenia gravis patients

    … a sensitive assay using a biosensor platform (Biacore™) for the measurement of these parameters in MG patients with MuSK antibodies. MuSK antigen was immobilized onto Biacore™ sensor chips and diluted sera injected over the surface to measure binding levels. Antibody isotype and subclass were …

    ubc Repository record for Using a biosensor platform for the detection and characterization of autoantibodies in myasthenia gravis patients (opens in a new tab)

  17. Generation and application of recombinant antibody fragments for prostate cancer detection.

    … kinetic analysis of candidate antibodies by Biacore. A differential expression profile of an anti-fPSA scFv and reformatted scAb was performed by ELISA. Individual antibodies isolated from the ‗biopanning‘ process were then characterised. The murine anti-fPSA antibodies were further analysed …

    dcu Repository record for Generation and application of recombinant antibody fragments for prostate cancer detection. (opens in a new tab)

  18. The production, characterisation and applications of polyclonal and monoclonal antibodies to warfarin

    … for warfarin and also for the development of a BIACORE-based inhibition immunoassay. A panel of murine monoclonal antibodies to warfarin was also generated by somatic cell fusion procedures, using the spleens of mice, following in vivo immunisation with a variety of warfarin-protein conjugates. …

    dcu Repository record for The production, characterisation and applications of polyclonal and monoclonal antibodies to warfarin (opens in a new tab)