Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"BOLD effect"”.

  1. Applications of magnetic resonance encephalography-spin-echo and multi-echo fMRI

    … based on the blood oxygenation level dependent (BOLD) effect has become a useful tool to study the functional connectivity of the human brain. However, conventional gradient-echo (GE) BOLD fMRI faces challenges like signal loss in areas with strong susceptibility gradients, reduced spatial …

    freiburg-diss Repository record for Applications of magnetic resonance encephalography-spin-echo and multi-echo fMRI (opens in a new tab)

  2. Inference of multi-scale connectivity in the brain

    … is to introduce a novel method to estimate effective connectivity of neural populations from continuous recordings of the activity of these populations which overcomes limitations of existing methods. This method estimates the connectivity of neural populations based on the covariance of the …

    freiburg-diss Repository record for Inference of multi-scale connectivity in the brain (opens in a new tab)

  3. MRI at 3 T of brain functions and fibre tracts adjacent to intracranial tumors

    … tumors (Paper 2); to investigate the effect of glioma resection on the spatial extent of fMRI activation as compared to the normal within-subject variability (Paper 3); to determine whether the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) can distinguish …

    lund Repository record for MRI at 3 T of brain functions and fibre tracts adjacent to intracranial tumors (opens in a new tab) Download PDF for MRI at 3 T of brain functions and fibre tracts adjacent to intracranial tumors (opens in a new tab)

  4. Functional brain mapping in mice

    … via the blood oxygenation level-dependent (BOLD) effect, which takes advantage of neurovascular coupling as surrogate of neuronal activity. Nociceptive studies in rats using fMRI have become integral parts of preclinical pain research. In contrast, mouse fMRI is far from being established, …

    fu-berlin Repository record for Functional brain mapping in mice (opens in a new tab)

  5. DEVELOPMENT OF MRI TECHNIQUES FOR MEASURING CEREBRAL BLOOD VOLUME, BLOOD FLOW, AND BLOOD OXYGENATION WITHIN A SINGLE SCAN

    … using the blood-oxygenation-level-dependent (BOLD) approach, which is sensitive to ensemble changes in cerebral blood volume (CBV), cerebral blood flow (CBF), and cerebral metabolic rate of oxygen (CMRO2). In order to understand and quantify the BOLD fMRI signal, it is essential to design …

    jhu Repository record for DEVELOPMENT OF MRI TECHNIQUES FOR MEASURING CEREBRAL BLOOD VOLUME, BLOOD FLOW, AND BLOOD OXYGENATION WITHIN A SINGLE SCAN (opens in a new tab)

  6. On the reproducibility and interpretability of group-level task-fMRI results

    … Ultimately, we conclude that exceedingly weak effects may not generalize across fMRI analysis software. </p> <p>In the second part of this work we shift our attention to the analytical methods applied for fMRI inference. Here, we seek to overcome limitations with the traditional statistical …

    oxford Repository record for On the reproducibility and interpretability of group-level task-fMRI results (opens in a new tab)

  7. Der kardiale BOLD-Effekt und die Narbendarstellung per delayed enhancement in der Magnetresonanztomographie im Vergleich zu Myokardszintigraphie und Koronarangiographie

    … wird als blood oxygenation level dependent(BOLD)-Effekt bezeichnet. In vorliegender Arbeit wurde die Technik der kardialen T2*-Messung an einem größeren Kol-lektiv von 55 Patienten mit vermuteter oder bekannter KHK erprobt. Die Messungen von T2* wurden in Atemanhaltetechnik mit einer …

    wurz-thes Repository record for Der kardiale BOLD-Effekt und die Narbendarstellung per delayed enhancement in der Magnetresonanztomographie im Vergleich zu Myokardszintigraphie und Koronarangiographie (opens in a new tab)

  8. Der BOLD-Effekt - eine nicht-invasive Messung der Blutsauerstoffsättigung im Herzen mittels T2-MRT in einem Schweinemodell einer akuten systemischen Hyper- und Hypoxämie

    … über einen Herzkatheter durchgeführt. Der BOLD-Effekt hat sich in jüngster Zeit als effektive Methode zur nicht-invasiven Bestimmung durch T2-Mapping im Blut erwiesen. Das Ziel dieser Studie war es, die Genauigkeit des BOLD-T2-Mappings mittels MRT mit der invasiven Bestimmung der …

    fu-berlin Repository record for Der BOLD-Effekt - eine nicht-invasive Messung der Blutsauerstoffsättigung im Herzen mittels T2-MRT in einem Schweinemodell einer akuten systemischen Hyper- und Hypoxämie (opens in a new tab)

  9. Quantitatively Studying Tissue Damage in Multiple Sclerosis Using Gradient Recalled Echo MRI Sequences

    … cause of it is still not definite and a fully effective treatment for MS is not yet available.Magnetic resonance imaging (MRI) has been used extensively in MS diagnosis and for monitoring disease. Clinical T1W, T2W and Fluid Attenuated Inversion Recovery (FLAIR) images are able to detect focal …

    wustl Repository record for Quantitatively Studying Tissue Damage in Multiple Sclerosis Using Gradient Recalled Echo MRI Sequences (opens in a new tab)

  10. Quantitatively Studying Tissue Damage in Multiple Sclerosis Using Gradient Recalled Echo MRI Sequences

    … cause of it is still not definite and a fully effective treatment for MS is not yet available.Magnetic resonance imaging (MRI) has been used extensively in MS diagnosis and for monitoring disease. Clinical T1W, T2W and Fluid Attenuated Inversion Recovery (FLAIR) images are able to detect focal …

    wustl Repository record for Quantitatively Studying Tissue Damage in Multiple Sclerosis Using Gradient Recalled Echo MRI Sequences (opens in a new tab)

  11. Investigation of brain tissue water NMR response by optimised quantitative single-voxel proton magnetic resonance spectroscopy

    … inflammation; and 4) estimation of the BOLD effect on the water spectral peak. The stability of the MR scanner used for all the investigations was assessed. Over the project period, the worst precision measurements of the scanner (for both water and metabolite signals) were observed to …

    glasgow Download PDF for Investigation of brain tissue water NMR response by optimised quantitative single-voxel proton magnetic resonance spectroscopy (opens in a new tab)

  12. Entwicklung und Optimierung leiser Magnetresonanz-Methoden für funktionelle Untersuchungen

    Ziel dieser Arbeit war die Entwicklung und Optimierung einer leisen Gradientenechosequenz für funktionelle Magnetresonanz-Experimente. Durch Modifikation der Gradientenformen wurde die Repetitionszeit einer ursprünglich von Hennel vorgeschlagenen Gradientenechosequenz um 28 verkürzt. Mit dieser …

    freiburg-diss Repository record for Entwicklung und Optimierung leiser Magnetresonanz-Methoden für funktionelle Untersuchungen (opens in a new tab)

  13. Combining EEG and MRI for the purpose of imaging neuronal currents in humans

    … based on the blood oxygenation level dependent (BOLD) effect, offers a resolution on the order of millimetres and seconds. However, none of these techniques applicable to humans offer a resolution on the length and time scale of neuronal processes (roughly micrometres and milliseconds, …

    zurich Repository record for Combining EEG and MRI for the purpose of imaging neuronal currents in humans (opens in a new tab)

  14. Tissue Damage Quantification in Alzheimer's Disease Brain via Magnetic Resonance Gradient Echo Plural Contrast Imaging (GEPCI)

    … for macroscopic magnetic field inhomogeneity effects and physiologic-motion-driven fluctuations in magnetic field as these are the major artifacts present with the gradient echo technique. The principal relaxation property used in this dissertation is the tissue-specific transverse relaxation …

    wustl Repository record for Tissue Damage Quantification in Alzheimer's Disease Brain via Magnetic Resonance Gradient Echo Plural Contrast Imaging (GEPCI) (opens in a new tab)

  15. Quality assurance in modern techniques of functional Magnetic Resonance Imaging (fMRI) based on BOLD using special anthropomorphic phantoms: applications in the stimulation of the motor and visual cerebral cortex

    … such as functional MRI (f MRI) which depends on BOLD(Blood Oxygen Level Dependant) contrast. The results of BOLD measurements rely on statistical analysis of the acquired signal and are sensitive to noise, SNR and even the examination conditions of the patientwith the use of stimulation devices. …

    greece Repository record for Quality assurance in modern techniques of functional Magnetic Resonance Imaging (fMRI) based on BOLD using special anthropomorphic phantoms: applications in the stimulation of the motor and visual cerebral cortex (opens in a new tab)