  1. Propagação de trinca por fadiga em risers rígidos

    … software and by the empirical expressions of BS7910, 2013. Elastoplastic analyses were performed and limited the propagation to a/t<0.8. Stress Intensity Factors (SIF) were calculated with the numerical method of the M-integral and generalized expressions were fitted. For a/t<0.5, the SIFs of …

    brazil-uerj Repository record for Propagação de trinca por fadiga em risers rígidos (opens in a new tab)

  2. Análise de criticidade de descontinuidade em um bocal de um vaso de pressão

    … de “fitness for service” empregando o guia BS7910 para avaliar um caso de um bocal de oito polegadas de diâmetro unido a um casco de dezesseis polegadas de diâmetro com uma grande descontinuidade do tipo falta de penetração em sua solda. A metodologia de fitness for service será comparada …

    brazil-ufrgs Repository record for Análise de criticidade de descontinuidade em um bocal de um vaso de pressão (opens in a new tab)

  3. Determinação da pressão de colapso em tubos API 5L X56 aplicando o método R6

    … Foi utilizado o método R6 conforme a norma BS7910:1999 e a Análise por Elementos Finitos. Foram feitos ensaios de tração e de caracterização da tenacidade do material utilizado por integral J, assim como o modelamento por Elementos Finitos do tubo e a aplicação dos “Failure Assessment …

    brazil-ufrgs Repository record for Determinação da pressão de colapso em tubos API 5L X56 aplicando o método R6 (opens in a new tab)

  4. Fracture and Failure Assessment of Fatigue-Cracked Circular Hollow Section X-Joints

    … assessment following the procedure outlined in BS7910 indicated that the level 2A assessment curve did not provide a conservative estimation on the failure load causing the brittle fracture observed in the experiment. The level 3C curve, in contrast, showed safe estimations. Based on the …

    nus Repository record for Fracture and Failure Assessment of Fatigue-Cracked Circular Hollow Section X-Joints (opens in a new tab)

  5. Assessment of Crack in Corrosion Defects in Natural Gas Transmission Pipelines

    … in comparison with the other methods, i.e. BS7910 and NG-18. The failure pressure for CIC defects for pipes tested fell between corrosion defects (lower bound) and crack defects (upper bound). The transition to crack defect behavior only occurs when the crack defect depth is significant or …

    waterloo Repository record for Assessment of Crack in Corrosion Defects in Natural Gas Transmission Pipelines (opens in a new tab)

  6. The effect of prior plastic strain on fracture initiation

    … integrity assessment procedures such as BS7910, prior plastic deformation during crack introduction is not taken into account when predicting the performance of components containing existing cracks. This leads to potentially overly-conservative assumptions about the integrity of the …

    bristol Repository record for The effect of prior plastic strain on fracture initiation (opens in a new tab)

  7. The influence of residual stresses on structural integrity of renewable energy marine structures.

    … steels and also the recommended trends in BS7910 using the 2-stage law and simplified law. Moreover, the specimen orientation, with respect to the weld geometry, has been examined and discussed in this work. This study presents, for the first time, residual stress characterisation in …

    cranfield Repository record for The influence of residual stresses on structural integrity of renewable energy marine structures. (opens in a new tab)

  8. Effects of structural steels microstructure and waveform on corrosion-fatigue behaviour of offshore wind turbine foundations.

    Marine structures in the offshore environment are subjected to constant cyclic wave and wind forces. Also, the foundations are in direct contact with seawater (SW), hence introducing corrosion damage in the structure. Due to the cyclic loading cracks could nucleate and grow, or existing cracks …

    cranfield Repository record for Effects of structural steels microstructure and waveform on corrosion-fatigue behaviour of offshore wind turbine foundations. (opens in a new tab)