Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 52 for “"Background Correction"”

  1. Background correction for DNA array data using a mixture model

    … to obtain high quality data from an experiment. Background correction is a first step for DNA array data processing; however, current methods for background correction have disadvantages. In this thesis, I propose a mixture model to facilitate the background correction for DNA array data …

    uvic Repository record for Background correction for DNA array data using a mixture model (opens in a new tab)

  2. Comparison of background correction in tiling arrays and a spatial model

    … experimental process and the machinery involved, correction methods are needed to restore the data to its true biologically meaningful state. Therefore, it is important that the algorithms developed to remove any sort of technical biases are accurate and robust. This report explores the concept of …

    ksu Repository record for Comparison of background correction in tiling arrays and a spatial model (opens in a new tab)

  3. Investigations into Background Correction and Retention Time Alignment to Enhance Quantitative Chemometric Analysis of Comprehensive Two-Dimensional Liquid Chromatography-Diode Array Detection Data

    … project was to determine a means of performing background correction that removed two background ridges. The methods of simply subtracting out a mean blank sample, singular value decomposition based background correction (SVD-BC) and asymmetrically weighted least squares (AWLS) were compared. …

    vcu Repository record for Investigations into Background Correction and Retention Time Alignment to Enhance Quantitative Chemometric Analysis of Comprehensive Two-Dimensional Liquid Chromatography-Diode Array Detection Data (opens in a new tab)

  4. Thermal monitoring of natural source zone depletion

    … temperature data to NSZD rates involves use of background-corrected temperature data, energy balances to resolve NSZD energy, and an estimate of heat produced through NSZD. All current computational methods for quantifying NSZD rates using temperature data have the drawbacks of: 1) incomplete …

    colostate Repository record for Thermal monitoring of natural source zone depletion (opens in a new tab)

  5. Spectrochemical Analysis Of Whole Powdered Coal

    … atomiser. The effects of furnace programme, background correction and air ashing were investigated. As, Se, Cd and Sb were successfully determined in a variety of certified reference material coals. For As the coal was slurried in nickel nitrate, magnesium nitrate, nitric acid and ethanol. …

    plymouth Repository record for Spectrochemical Analysis Of Whole Powdered Coal (opens in a new tab)

  6. Optimization of thermal background suppression through Principal Component Analysis: Application to nulling interferometric observations of warm exozodiacal dust

    … in the N-band (11 $\mu$m), the thermal background is a major limit to the data's sensitivity and a challenge to the extraction of relevant information. In fact, the thermal background can even outshine the star, let alone circumstellar emissions. Thus, an effective background subtraction …

    liege Repository record for Optimization of thermal background suppression through Principal Component Analysis: Application to nulling interferometric observations of warm exozodiacal dust (opens in a new tab)

  7. Ανάπτυξη μεθοδολογιών υπολογιστικής νοημοσύνης για την επεξεργασία και ανάλυση δεδομένων γονιδιακής έκφρασης μικροσυστοιχιών cDNA

    … in the first part of this thesis, the problem of background estimation and correction of two-channel microarray data is addressed and two novel algorithms are proposed, namely the percentiles-based and the loess-based background correction methods. Both approaches are based on the multiplicative …

    greece Repository record for Ανάπτυξη μεθοδολογιών υπολογιστικής νοημοσύνης για την επεξεργασία και ανάλυση δεδομένων γονιδιακής έκφρασης μικροσυστοιχιών cDNA (opens in a new tab)

  8. Improving Experimental Outcomes in Kinome Microarrays Through Quality Control

    … as foreground signal and pixels interpreted as background signal. In this thesis, it is shown that too large of a spot size creates abnormal data characteristics, such as high skewness (the asymmetry of the distribution of the data), that can alter downstream results. Here, a feature is …

    sask Repository record for Improving Experimental Outcomes in Kinome Microarrays Through Quality Control (opens in a new tab)

  9. A novel spectropolarimeter for determiation of sucrose and other optically active samples.

    … which makes it suitable for colored samples. Background correction before apparent absorbance measurements, combined with multivariate statistical analysis over a wide spectral range, proved efficient to avoid chemical pretreatment of the samples. The instrument showed good performance for …

    baylor Repository record for A novel spectropolarimeter for determiation of sucrose and other optically active samples. (opens in a new tab)

  10. Investigation and Correction for the Partial Volume Spill in Effects in Positron Emission Tomography

    … well as application of post-filtering, using the background correction technique. This thesis involved analytical simulations for the digital XCAT2 phantom, and validation acquiring data from NEMA phantoms and patient datasets with the GE Signa PET/MR and Siemens Biograph mMR/mCT scanners. …

    whiterose Repository record for Investigation and Correction for the Partial Volume Spill in Effects in Positron Emission Tomography (opens in a new tab)

  11. Femtosekundinė priverstinės Ramano sklaidos spektroskopija, naudojant siaurajuostės spinduliuotės spektrinę moduliaciją /

    … modulation in FSRS setups can be usefull for background correction. Data processing has been done by using semi – automated Raman peak position detection based on continuous wavelet transform method.

    vilnius Repository record for Femtosekundinė priverstinės Ramano sklaidos spektroskopija, naudojant siaurajuostės spinduliuotės spektrinę moduliaciją / (opens in a new tab)

  12. Investigation of Matrix Effects on the Furnace Atomic Absorption Signals of Chromium, Nickel and Selenium

    … were investigated using Polarized Zeeman Effect background correction in conjunction with a detector/readout system capable of resolving absorbance signals in 18 msec readings. Both optical temperature control and current temperature control were employed for each analysis. Peak area, peak …

    odu Repository record for Investigation of Matrix Effects on the Furnace Atomic Absorption Signals of Chromium, Nickel and Selenium (opens in a new tab)

  13. DEVELOPMENT OF MAP/REDUCE BASED MICROARRAY ANALYSIS TOOLS

    … I implemented microarray quality assessment, background correction, normalization and summarization algorithms using the Map/Reduce framework. The Map/Reduce framework, first introduced by Google in 2004, offers a promising paradigm to develop scalable parallel applications for large-scale …

    clemson Repository record for DEVELOPMENT OF MAP/REDUCE BASED MICROARRAY ANALYSIS TOOLS (opens in a new tab)

  14. Determinação de cádmio, chumbo, tálio e zinco em águas e alimentos por espectrometria de absorção atômica com injeção de amostra em forno aquecido por chama (BIFF-AAS)

    … negligible in spectrometers furnished with D2 background correction system. Without background correction, only Na in high concentrations (> 1000 mg l-1) showed significant spectral interference. Limits of detection were 0.65 µg l-1 Cd, 32.0 µg l-1 Pb, 8.0 µg l-1 Tl e 5.0 µg l-1 Zn. The …

    brazil-ufscar Repository record for Determinação de cádmio, chumbo, tálio e zinco em águas e alimentos por espectrometria de absorção atômica com injeção de amostra em forno aquecido por chama (BIFF-AAS) (opens in a new tab)

  15. Characterization of polymer-modified electrodes from transient ultramicroelectrode experiments

    … The sensitivity of the analysis to proper background correction is discussed in the light of previous literature and demonstrated experimentally using the well studied Fe(CN)$\sb6\sp{-3/-4}$ system. This technique is used to measure diffusion coefficients and concentrations of benzoquinone …

    uiuc Repository record for Characterization of polymer-modified electrodes from transient ultramicroelectrode experiments (opens in a new tab)

  16. Precision Measurement of the Proton's Weak Charge using Parity-Violating Electron Scattering

    … is also presented, with a focus on the beamline background correction, the nonlinearity measurement, and the simulation to constrain error for a rescattering effect. Also detailed here is the final, unblinded Qweak result, which determined Qpw to 6.2% and provided the highest precision …

    vt Repository record for Precision Measurement of the Proton's Weak Charge using Parity-Violating Electron Scattering (opens in a new tab)

Page 1 of 3