Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 142 for “"Background signal"”.

  1. Ultrathin Single and Multi-Channel Fiberscopes for Biomedical Imaging

    … via a beamsplitter results in a lowobject to background signal ratio. The low contrast image is due to a low collectionefficiency of light from the ob ject as well as a high background signal from the Fresnelreflection at the proximal surface of the fiber bundle, where the illumination enters …

    arizona-thes Repository record for Ultrathin Single and Multi-Channel Fiberscopes for Biomedical Imaging (opens in a new tab)

  2. High dynamic range CMOS-integrated biosensors

    … sample preparation, biomolecular recognition, signal transduction and data analysis. With vii the recent advancements in very large scale integration (VLSI) and fabrication technologies, it is now possible to integrate several of these biosensing components into a small form factor. This thesis …

    texas Repository record for High dynamic range CMOS-integrated biosensors (opens in a new tab)

  3. Fast widefield techniques for fluorescence and phase endomicroscopy

    … tissue is often hampered by strong out-of-focus background signal. Laser scanning confocal endomicroscopy has been developed for optically-sectioned imaging free from background, but reliance on mechanical scanning fundamentally limits the frame rate and represents significant complexity and …

    bu Repository record for Fast widefield techniques for fluorescence and phase endomicroscopy (opens in a new tab)

  4. A Study of the Development of an Electrochemical Point-of-Care Urine Analysis Platform for Pathogen Screening

    … system by creating an assay that combines low background signals with built-in amplification. In this work, gold disk macroelectrodes are used in conjunction with a bio-recognition layer to capture pathogen-related nucleic acids and then this event is translated into an electrochemical signal. …

    mcmaster Repository record for A Study of the Development of an Electrochemical Point-of-Care Urine Analysis Platform for Pathogen Screening (opens in a new tab)

  5. Investigation of a background suppression transimpedance amplifier for photovoltaic detectors

    … at a high gain or in the presence of a large background signal. To eliminate saturation, an amplifier that is frequency dependent is developed. Additionally, the noise sources in the conventional transimpedance amplifier and photovoltaic detector are quantified for comparison to any modified …

    nps Repository record for Investigation of a background suppression transimpedance amplifier for photovoltaic detectors (opens in a new tab)

  6. Investigations into the feasibility of EXAFS measurements on the local lattice structure near isolated impurities in crystals

    … with estimations of the magnitude of the background signal that would be present in any EXAFS measurement on impurities, indicates that with existing technologies even these preliminary samples could only give marginally acceptable results. For this reason the actual experiment was not …

    rice Repository record for Investigations into the feasibility of EXAFS measurements on the local lattice structure near isolated impurities in crystals (opens in a new tab)

  7. Investigation of Electrode Processes and Double Layer Structure Using Visible/infrared Sum Frequency Generation

    … crystal Ag azimuthal rotation on resonant SFG signal line shapes is examined using broad band multiplex SFG. Detailed fitting analysis of acquired spectra is used to extract data as a function of azimuthal rotation angle. Magnitude of non-resonant background, relative phase of vibrational …

    uiuc Repository record for Investigation of Electrode Processes and Double Layer Structure Using Visible/infrared Sum Frequency Generation (opens in a new tab)

  8. SIMULTANEOUS ARTIFACTS CORRECTION AND ACCELERATION FOR CHEMICAL EXCHANGE SATURATION TRANSFER IMAGING VIA DEEP LEARNING

    … agents. CEST MRI methods rely on molecular signal saturation through radiofrequency pulses with the same frequency as a prescribed molecule (e.g., glutamate) to be measured in a magnetic field. Because the background signal from water modular is generally greater than the signal from the …

    temple Repository record for SIMULTANEOUS ARTIFACTS CORRECTION AND ACCELERATION FOR CHEMICAL EXCHANGE SATURATION TRANSFER IMAGING VIA DEEP LEARNING (opens in a new tab)

  9. Pulsed electrochemical detection of organic sulfur compounds at gold electrodes

    … of surface oxide, which results in a large background signal and the rapid poisoning of anodic activity. A three-step pulsed electrochemical detection (PED) waveform can be applied to maintain electrode activity and detect sulfur compounds following their separation by liquid chromatography. …

    iastate Repository record for Pulsed electrochemical detection of organic sulfur compounds at gold electrodes (opens in a new tab)

  10. A feasibility study for electron-muon correlations at ALICE

    … The e-μ channel would provide a much cleaner/low background signal than other currently-utilized probing methods, but it is statistics-limited, a re-striction which is of increased concern at ALICE due to the detector's geometry. With the use of Pythia simulations, the viability of undertaking an …

    cape-town Repository record for A feasibility study for electron-muon correlations at ALICE (opens in a new tab)

  11. Dark Matter Annihilation and the Observed Positron Excess

    … show a flux of positrons above the expected background signal; this positron excess may point toward a primary source of positrons that could be explained by dark matter annihilations. Utilizing DarkSUSY to generate supersymmetric models in which the neutralino is the dark matter, we find …

    creighton Repository record for Dark Matter Annihilation and the Observed Positron Excess (opens in a new tab)

  12. A novel inspection system for aircraft engine turbine disks

    … techniques is difficult owing to the significant background signal from the edge. This thesis deals with the development of a reliable inspection system using a scanning novel technique comined with an eddy current test method. The scanning system performs well in detecting surface cracks existing …

    iastate Repository record for A novel inspection system for aircraft engine turbine disks (opens in a new tab)

  13. Application of non-imaging optical inspection to the detection of pinhole defects in latex condoms

    … to maximize contrast between pinhole transmitted signal and optical signal transmitted through the latex condom material, ultraviolet (u.v.) light of wavelength 253nm has been used. This inspection was performed during rotation of the condom, with the light source inside the condom and the …

    njit Repository record for Application of non-imaging optical inspection to the detection of pinhole defects in latex condoms (opens in a new tab)

  14. Clostridium perfringens and the beta2 (CPB2) toxin: Development of a diagnostic ELISA for neonatal piglet enteritis, and distribution of the gene in isolates from selected animal species

    … to be adjusted because of the presence of high background signal in some samples consistent with intestinal proteases. This was overcome by processing the samples at 4oC and using citrate buffer pH 6.1 containing 5% bovine serum albumin. The second objective was to identify cpb2 in Clostridium …

    guelph Repository record for Clostridium perfringens and the beta2 (CPB2) toxin: Development of a diagnostic ELISA for neonatal piglet enteritis, and distribution of the gene in isolates from selected animal species (opens in a new tab)

  15. Development of new polymer mass tag reagents for mass cytometry

    … (IMC) on the same Pt MCP-Ab conjugates had high background signal due to NSB. Images obtained on Ab conjugates of GSH treated Pt MCPs, had greatly reduced NSB, background signal and were highly specific to their intended targets. In the third part of my thesis, I describe the loading of Pd or Hg …

    toronto-retro Repository record for Development of new polymer mass tag reagents for mass cytometry (opens in a new tab)

  16. PULSED DOUBLE-QUANTUM COHERENCE ELECTRON PARAMAGNETIC RESONANCE IN PROTEIN STRUCTURE DETERMINATION

    … the inter-spin distance from the dipolar EPR signal. Double-quantum coherence (DQC) and double electron-electron resonance (DEER) are two such methods primarily used in studying the structure of proteins and other biomacromolecules. There are two main classes of spin labels used in PDS …

    cornell Repository record for PULSED DOUBLE-QUANTUM COHERENCE ELECTRON PARAMAGNETIC RESONANCE IN PROTEIN STRUCTURE DETERMINATION (opens in a new tab)

  17. Building practical apertureless scanning near-field microscopy

    … and these tips are used to detect near-field signal. Separating the weak a-SNOM system signals from the undesired background signal, the higher demodulation background suppression is utilized by lock-in detection.

    alabama Repository record for Building practical apertureless scanning near-field microscopy (opens in a new tab)

  18. Development of The Ark Assay For Quantitating Dna- Protein Crosslink Accumulation and Fanconi Anemia Pathway Involvement In The Repair Process

    … and anionic denaturation to remove excessive background signal, is premised upon isolating and measuring DPC-associated DNA and free, soluble DNA fragments. We show that the ARK assay effectively detects DPCs induced by a range of agents, and that DPC-defective models exhibit increased DPC …

    uthsc Repository record for Development of The Ark Assay For Quantitating Dna- Protein Crosslink Accumulation and Fanconi Anemia Pathway Involvement In The Repair Process (opens in a new tab)

  19. Improved sensitivity in fluorescence spectroscopy and microscopy

    … challenges still remain due to endogenous background signal that obscures measurements and spatial resolution that is limited by excitation and emission wavelengths. This work describes sensitivity and resolution improvements to fluorescence-based measurements through a combination of …

    gatech Repository record for Improved sensitivity in fluorescence spectroscopy and microscopy (opens in a new tab)

  20. A foreground detection system for automatic surveillance

    … segmenting foreground objects from the static background in the videos. In this thesis we introduce a novel system for background subtraction, which takes a di erent approach than the conventional background subtraction systems. We make the assumption that the video background is stationary and …

    uiuc Repository record for A foreground detection system for automatic surveillance (opens in a new tab)

Page 1 of 8