Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"Backwash water"”
-
Effects of backwash water recirculation in drinking water treatment - A case study on coagulation, flocculation, and sedimentation performance in Sweden
… investigate the impact of recycling spent filter backwash water (SFBW) in coagulation, flocculation and sedimentation processes in a Swedish drinking water treatment plant. The study focused on interpreting these effects based on dissolved organic carbon (DOC), turbidity reduction, and visual floc …
-
The Effect of Recycled Backwash Water Operations on Fouling in a Coagulation-Ultrafiltration Process and Impact of Preozonation on Membrane Productivity
… ultrafiltration (UF) membranes used for drinking water treatment, and was segmented into four key components. (1) In the first component of the work, the long-term fouling behavior of a polyethersulfone (PES) hollow-fiber UF membrane was studied at the pilot-scale for treatment of surface water …
-
Caracterização de água de lavagem de filtros em estações de tratamento de água de filtração direta
The water supply and treatment is considered as a great benefit considering that, if done efficiently, provides public health. However, considering the WTP (Water Treatment Plant) is an industry, with its inputs and waste generation, they must be constantly evaluated and monitored to verify the …
-
Drinking Water Biofilters-impacts of backwashing techniques at full scale
… and performance of biofilters requires routine backwashing, an event that may disrupt biofilter health and functionality. This study investigates the impact of backwashing on the performance of microbial biofilters at Britannia and Lemieux Water Treatment Plants. More specifically, the effects …
-
Management model to optimise the use of reverse osmosis brine to backwash ultra–filtration systems at Medupi power station
According to the Department of Water Affairs (DWAF, 2004 p.15), South Africa's water resources are scarce and extremely limited and much of this precious resource is utilised and consumed in our industries. Treatment and re-use of effluent generated is, in some cases, preferred over use of …
-
Evaluation of Rinse Water Recirculation Alternatives at Lackarebäck Water Treatment Plant
Water treatment plants generate large volumes of residual streams during normal drinking water production. At Lackarebäck, one of two water treatment plants in Gothenburg, these streams currently amount to approximately 6,300 m3 per day and are discharged without any reuse. This thesis evaluates …
-
Optimization of an Advanced Water Treatment Plant: Bromate Control and Biofiltration Improvement
The David L. Tippin Water Treatment Facility (DLTWTF) serving the city of Tampa, Florida is an advanced drinking water treatment facility consisting of coagulation/flocculation, ozonation, granular activated carbon biofiltration, and disinfection by chloramine. New regulations and the recent …
-
Backwash Optimization for Drinking Water Treatment Biological Filters
… study was conducted to examine the impacts of backwashing on biofiltration performance. Collapse pulsing resulted in significantly higher DOC removals (21%) compared to the water only backwash (13%). Three backwash procedures were investigated under nutrient supplemented conditions. Employing a …
-
Produção de água em ETA com alteração da carreira de filtração
Water treatment plants are designed according to the water quality on source, which directly sets up the treatment technology to be used and consequently influences costs of operation and maintenance. The adequacy of the processes in WTP is primordial for reducing costs and improving the quality of …
-
Efeitos da recirculação de água de lavagem de filtros em um sistema de filtração direta em escala de bancada
The residues generated in the Water Treatment Plants (WTP) are mainly formed by the sedimentation and the filter backwash water (FBWW). The FBWW represents the largest portion of water loss, and may comprise up to 10% of the station's flow. An alternative to the destination of this waste is the …
-
A Tidal Prism analysis of the soluble copper mixing zone around the Occoquan Water Treatment Plant
The Fairfax County Water Authority applies copper sulfate as an algaecide in the Occoquan Reservoir to control the growth of taste and odor causing algae. The Occoquan Water Treatment Plant removes water from the reservoir for distribution to portions of Fairfax County. Approximately once a day, …
-
Estudo de influência de cobertura plástica na remoção de água de lodos de estações de tratamento de água em leitos de drenagem
Most of Water Treatment Plant (WTP) for public supply in Brazil use surface water as source and conventional complete cycle as treatment system. In this type of treatment wastewater are restrained/generated which vary mainly according to the type and amount of chemical added and the characteristics …
-
A mathematical model for rapid gravity filter backwashing
A mathematical model for backwashing rapid gravity filters using a fluidising water wash has been developed. The model development has benefited from previous research carried out using a high speed video camera to obtain fundamental insights into the physical mechanisms of the backwash process. …
-
Sistema de leito de drenagem e sedimentador como solução para redução de volume de lodo de decantadores e reuso de água de lavagem de filtros
Water supply systems utilize, in most cases, conventional Water Treatment Plants (WTPs). These plants use alum and ferric salts in their coagulation process, and produce residues (sludge) mainly in filter systems and decanter tanks. The produced residues may be toxic to man and are usually disposed …
-
Filter backwashing mechanisms
An investigation of filter backwashing mechanisms was undertaken. High speed video recording equipment, operating at 200 frames/s, in conjunction with a rigid endoscope (borescope) has been used to obtain detailed visual information from inside the filter bed during backwash. In addition, …
-
Feasibility of Pulsed Air Operation in a Fixed Film Biological Reactor
… film biological reactor receiving domestic wastewater feed (primary effluent). The pulsed mode of aeration was compared to continuous flow or non-pulsed aeration based on BOD5 and TSS removals. The reactor utilized 0.19 to 0.20 in. (ES) gravel media with a 5.5 ft. depth. Automatic backwashing was …
-
Evaluation of granular media to wastewater treatment; advanced primary treatment utilising modified pumice, titanomagnetite and ceramic nozzles.
The treatment of wastewater to higher standards is becoming increasingly important as legislation and public perception demand reduced impact of human activity on the environment. Filtration of primary treated effluent (PTE) and secondary treated effluent (STE) offers a possible sustainable …
-
Exploring the Interplay of Operational Conditions, Microbial Communities, and Water Quality in Drinking Water Ozone-Biofiltration
Ensuring reliable access to safe drinking water is a growing global challenge as water utilities face variable source water quality driven by population growth, land‑use change, and climate change impacts. To address these challenges, utilities are implementing advanced treatment technologies …
-
Improving the Understanding of Factors Influencing Cryptosporidium Removals Reported for Granular Media Filtration
Cryptosporidium is an important waterborne protozoan pathogen which has been implicated in several large gastrointestinal disease outbreaks attributable to inadequate treatment of drinking water. Unfortunately, Cryptosporidium oocysts, the life cycle phase found in water, are highly resistant to …
-
Recyklace vod z praní filtrů v bazénových provozech.
Bakalářská práce se zabývá úpravou vody z praní filtrů v bazénových provozech ve světě a v ČR. Úvod práce je věnován obecnému popisu recirkulační úpravny bazénových vod a obecnému popisu recyklační linky pracích vod z filtrů a využití vody z recyklace. Práce zmiňuje vybrané sledované ukazatele, …
Page 1 of 2