Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 14 of 14 for “"Bar stresses"”

  1. Performance of tension lap splices with MMFX high strength reinforcing bars

    … obtained from splice tests failing primarily at bar stresses less than their respective maximum allowable design yield strengths for tensile reinforcement of 80 ksi and 75 ksi. Limited data exists for splices failing at bar stresses greater than 75-80 ksi, and no data exists for splices failing …

    texas Repository record for Performance of tension lap splices with MMFX high strength reinforcing bars (opens in a new tab) Restricted access

  2. Lap Splicing of Large High-Strength Steel Reinforcing Bars

    Use of large bars is advantageous in large structures like nuclear power plants. Nevertheless, ACI 318-19 prohibits tension lap splices for bars larger than No. 11 [36 mm] because limited test data are available. Eleven large-scale reinforced concrete beams with tension lap splices were tested …

    ku Repository record for Lap Splicing of Large High-Strength Steel Reinforcing Bars (opens in a new tab)

  3. Bond of LAP-spliced bars in self-compacting concrete

    … equation for normal vibrated concrete predicted bar stresses of the unconfined specimens produced with self-compacting concrete acceptably well. The predicted values were lower than the measured values to be on the safe side. The error varied between 3.4% and 6.5%. All predictions of the ACI408 …

    metu Repository record for Bond of LAP-spliced bars in self-compacting concrete (opens in a new tab)

  4. Precast Deck Joints using FRP and Ultra-High Performance Concrete

    … with Glass Fiber Reinforced Polymer (GFRP) bars with cast-in-place joints made using Ultra-High Performance Concrete (UHPC). This thesis investigates the bond between GFRP bars and UHPC and splice length optimization to obtain narrow joints and simplified bar geometries. Multiple linear …

    uwo Repository record for Precast Deck Joints using FRP and Ultra-High Performance Concrete (opens in a new tab)

  5. Bond Strength of ASTM A 1035 Grade 100 Reinforcing Steel

    … Parameters studied include splice length, bar size, concrete compressive strength, cover, and the amount of confining transverse reinforcement. Lap splices developed bar stresses varying from 68 ksi to 155 ksi prior to splitting bond failure. Results indicate that the ACI 318-05 development …

    ku Repository record for Bond Strength of ASTM A 1035 Grade 100 Reinforcing Steel (opens in a new tab)

  6. Development length equation for high-strength materials

    … by the term [minimum side cover, cover over the bar or wire, or one-half the center-to-center spacing of the bars or wires] + [contribution of confining reinforcement across potential splitting planes] / [normal diameter of bar] in ACI 318-05. The basic assumption is that bar stress is a linear …

    texas Repository record for Development length equation for high-strength materials (opens in a new tab) Restricted access

  7. Increasing service life at bridge ends of moveable abutment bridges

    … insight into approach slab behavior and tie bar stresses due to friction. Parametric studies were completed on various approach slab properties including friction with soil, soil stiffness, tie bar style, and bridge skew. The outcome of this study includes recommendations for improving bridge …

    iastate Repository record for Increasing service life at bridge ends of moveable abutment bridges (opens in a new tab)

  8. Exploring Fiber-Reinforced Polymer Concrete for Accelerated Bridge Construction Applications

    … explore the impact of splice length, side cover, bar size, and temperature on bar stress in non-contact splice specimens. The test setup was similar to that completed by the Federal Highway Administration (FHWA) with UHPC. The results of the testing program indicate that FRPC exhibits significant …

    washington Repository record for Exploring Fiber-Reinforced Polymer Concrete for Accelerated Bridge Construction Applications (opens in a new tab)

  9. Study of support bearing details on response of deep beams

    … tension tie reinforcement anchored by straight bar embedment resulted in the longest beam. Identical overall lengths were provided for the specimens anchored using 90° standard hooks and friction-welded headed bars of head size 1.5 in. (38 mm). Finally, the shortest beam was anchored using …

    mcgill Repository record for Study of support bearing details on response of deep beams (opens in a new tab)

  10. Anchorage of Headed Reinforcing Bars in Exterior Beam-Column Joints

    In reinforced concrete members, headed bars are often used to anchor reinforcing steel when member geometry is insufficient for the full development of straight bars; the shorter development lengths and compact size also reduce congestion. Currently, very limited research has been performed on the …

    ku Repository record for Anchorage of Headed Reinforcing Bars in Exterior Beam-Column Joints (opens in a new tab)

  11. ANCHORAGE OF HIGH-STRENGTH REINFORCING BARS WITH STANDARD HOOKS

    Hooked bars are often used to anchor reinforcing steel where concrete dimensions are not sufficient to provide the required development length for straight reinforcement, such as in external beam-column joints. The purpose of this study is to expand the understanding of the behavior of hooked bars …

    ku Repository record for ANCHORAGE OF HIGH-STRENGTH REINFORCING BARS WITH STANDARD HOOKS (opens in a new tab)

  12. ANCHORAGE STRENGTH OF STANDARD HOOKED BARS IN SIMULATED EXTERIOR BEAM-COLUMN JOINTS

    The current ACI hooked bar design provisions are based on test results of 38 simulated beam-column joints containing two hooked bars. The provisions address the effects of hooked bar surface condition, concrete cover, amount of confining reinforcement confining the hooks, and type of concrete …

    ku Repository record for ANCHORAGE STRENGTH OF STANDARD HOOKED BARS IN SIMULATED EXTERIOR BEAM-COLUMN JOINTS (opens in a new tab)

  13. Experimental and Analytical Investigation of Continuity Diaphragms in Continuous Precast Prestressed Concrete Bridges

    … girders consisting of interlocking hairpin bars which was adopted by Virginia Department of Transportation (VDOT). In 2021, a new approach to the design of continuity diaphragms was proposed and approved for inclusion in the 10th edition of the AASHTO Specifications (2024) to allow for …

    vt Repository record for Experimental and Analytical Investigation of Continuity Diaphragms in Continuous Precast Prestressed Concrete Bridges (opens in a new tab)

  14. 3D strut-and-tie design recommendations for column and drilled shaft anchorages in drilled shaft footings

    … footing specimens designed with different column bar anchorage details: straight bars, hooked bars with two different hook orientations, and headed bars. All column reinforcement in Phase II specimens could yield during the tests regardless of the anchorage types. Furthermore, all anchorage types …

    texas Repository record for 3D strut-and-tie design recommendations for column and drilled shaft anchorages in drilled shaft footings (opens in a new tab)