Design of a "Free from damage" column base connection for seismic applications
… uma estratégia de dimensionamento inovadora baseada no desenvolvimento de estruturas incluindo amortecedores por atrito em ligações, apropriadamente dimensionadas para evitar qualquer dano em elementos de aço. O objectivo do estudo é o desenvolvimento de uma ligação de base de coluna …
-
Influence of Column-Base Fixity On Lateral Drift of Gable Frames
… the wind drift analysis, which assumes pinned connections at the base. The pinned connections provide no moment at the base and have zero rotational stiffness. However, in reality every connection provides some restraint and has some rotational stiffness. Hence, by considering a modeling …
-
Seismic Stability Response and Design of Wide Flange Columns in Steel Framed Structures
… ratios as well as stiffness and strength of the base connection. Preventing instability of steel wide-flange columns during earthquakes is essential for ensuring the safety, reliable seismic performance, and post-earthquake recovery of steel framed structures. Current seismic stability …
-
Structural Optimization using the Principle of Virtual Work and an Analytical Study on Metal Buildings
… understanding the behavior of structural systems based on the principle of virtual work was developed by Dr. Finley Charney in the early 1990s. The program was called DISPAR, which stands for DISplacement PARticipation factors, and was written to work in accordance with SAP90 and ETABS. This …
-
SSH over UDP
… is using TCP consistently for all its network connections and thus for its VPN feature. This causes the VPN feature to tunnel one TCP connection within another TCP connection. Many sources say that TCP in TCP tunneling, under realistic conditions, can give rise to conflicts between the two TCP …
-
Análise numérico-experimental de chumbador de base de pilar de aço submetido ao cisalhamento
The column base connection is responsible for transferring the superstructure actions to the foundation and consists, typically, of a base plate and threaded steel bars or anchor rods. A grout layer is used for filling the clearance between the base plate and the top of concrete block, usually …
-
Moment-resistant connections in precast concrete
… on two commercially available column-to-base connection arrangements. The structural characteristics of both systems are presented in the form of moment-rotation curves. A method by which these connections can be used in a practical design problem is proposed. One type of moment-resistant …
-
Parametric Study of Fatigue in Light Pole Structures
… criteria that incorporate loading conditions and connection detail categories.Initiative for the study was the occurrence of failures due to rapid fatigue resulting from wind induced vibration. Several failures have been associated with welded hand- hole details that have not been the subject of …
-
Fragility approach for performance-based design in fluid-structure interaction problems, Part I: Wind and wind turbines, Part II: Waves and elevated coastal structures
… focuses on a methodology for performance-based design using fragilities in fluid-structures interaction problems. Two types of fluid-structure interaction problems are investigated in this dissertation: Part I: wind-structure interaction (for wind turbine tower-base fatigue), and Part II: …
-
Fatigue performance of multi-sided high-mast lighting towers
… poles primarily occur just above the weld at the base plate connection indicating a fatigue type failure. Although these structures are designed to the current 2001 AASHTO Specification, their susceptibility to fatigue failure has become a nationwide problem. The objective of this research was to …
-
Computer modeling analysis of a steel framed support tower for the energy and environmental research center
… program was needed that could maintain a database for updating future changes in the structure, provide a current analysis picture, and generate as-built drawings. The program selected was STAAD III/ ISDS used in conjunction with Autostaad, a pre- and post-processing program that functions in …
-
Behavior of Welded Aluminum Light-pole Details near Fatigue Limit
… structural systems subjected to cyclic loading based on the response to wind. As a result, fatigue life analysis and design of such systems are necessary. A number of welded aluminum light-pole specimens have been fatigue tested, and for convenience, are broken down into three groups for ease of …
-
Design of One-Story Hollow Structural Section (HSS) Columns Subjected to Large Seismic Drift
… elastic design, plastic hinge design, and pinned base design. First, for elastic design, the compression and flexural strength of the HSS columns are calculated according to the AISC specifications, and the story drift ratio that causes the interaction equation to be violated for varying axial …
-
Rotational Strength and Stiffness of Shallowly Embedded Base Connections in Steel Moment Frames
Shallowly embedded column base connections with unreinforced block out concrete are a common method of connecting steel columns to their foundation. There has been little research done to accurately quantify the effects of this block out concrete on the connection strength and rigidity, and …
-
Cross laminated timber shear wall connections for seismic applications
… timber (CLT) shear wall systems and connections for seismic applications. CLT panels are gaining popularity as a building material because of their biaxial strength and light weight. CLT panels can be used in building construction not only as floors, but also as shear walls. However, …
-
Numerical Modelling of Exposed Base Plate Connections and Their Influence on System-level Seismic Response
Gravity columns with exposed base plate connections are often assumed as pinned in both analysis and design. However, past experiments have shown that base plate connections can provide a significant level of flexural strength and stiffness. This study investigates the influence that the effect of …
-
Assessment of Analytical Procedures for Designing Metal Buildings for Wind Drift Serviceability
… drift, for simplicity of analysis and design, connection at base of column is considered as pinned which provides no rotational restraint. The actual behavior of the connection however, is partially rigid, that provides some rotational stiffness even in case of single row of bolts. Moreover, …
-
Poiana: A Biophilic Balance (A proposal for biophilic consideration during design & development in the ruralcountryside of Romania)
… an innate desire humans exhibit toward creating connections to other living things, whether it be other humans or the surrounding environment. I suspect this stems from our evolution from hunter-gatherers into an agrarian civilization. The nineteenth century and industrial revolution marked a …
-
Fatigue reliability assessment and inspection scheduling for High-Mast Illumination Poles
… of severe fatigue-induced cracks at the shaft-to-base connection at the bottom of the poles. These cracks are believed to exist due to the galvanization process prior to deployment. Also, an unanticipated increase of fatigue demand from vortex-induced vibration is believed to exacerbate the …