Constructing an Innovative Base-Isolation System under Masonry Structures
… intrusive, monitorable and removable. A novel base-isolation technique has been proposed for the up-gradation of existing buildings against seismic actions which does not involve any alteration in existing buildings, and it is monitorable and removable. The method asks for the uncoupling of …
-
Mechanics, Characterization, and Design of an Adaptive Variable Friction Base Isolation System
… for high performing and resilient structures, base isolation has increasingly been utilized to reduce seismic forces on structures and further tailor structural response. Though many isolators are currently available, few offer the ability to tailor structural response at more than one demand …
-
Adaptive Control of Base Isolation Systems Using the Transmissibility-Based Semi-Active Controller
Base isolation system is one of the most effective seismic protection systems which is widely used to protect buildings of high importance against seismic hazards. However, the performance of these systems might be impaired under long-period earthquake ground motions due to the resonance effect. …
-
Experimental investigation of the base storey design of base isolated steel buildings
Recent research indicates that base isolation of buildings eliminates or reduces seismic loading to an acceptable level. This paper presents the results of the experimental investigations of various base storey schemes for steel buildings with base isolation. A steel frame was designed and built …
-
A Study of Neural and Conventional Control Paradigms in Active Digital Control
… chosen for investigation. The first problem is a base isolation system which is an example of rigid body structural control. The second problem involves the reduction of excessive vibrations of a nonlinear (geometrically) cantilevered plate structure which is an example of flexible structural …
-
Ανάπτυξη μεθοδολογιών ανάλυσης και σχεδιασμού συστημάτων σεισμικής μόνωσης της βάσης των κτηρίων για την ελαχιστοποίηση της στρεπτικής τους απόκρισης.
Base isolation is one of the most recent and effective means of protecting a structure against the devastating effects of strong earthquake motions. In case of structures with plan asymmetries though, the torsional response of the base isolation system may be significant. This means that the …
-
Study of seismic control systems on the behaviour of industrial storage racks
… orthogonal directions using two different frame systems: moment resisting frames in down aisle direction and braced frames in cross aisle direction. The design of racks is different from typical buildings because they are made of slender thin walled members, hence, making them sensitive to …
-
Equivalent Linearization Analysis Method for Base-isolated Buildings
Base isolation system, as one of the most popular means to mitigate the seismic risks, often exhibits strong nonlinearity. To simplify the procedure of structural design, bilinear force-deformation behavior is recommended for isolation systems in most modern structural codes. Although base …
-
Multi-resonant Electromagnetic Shunt in Base Isolation for Vibration Damping and Energy Harvesting
… multi-resonant electromagnetic shunt in base isolation. In this research, two multi-resonant shunt configurations, parallel and series, were proposed and optimized based on the H2 criteria when the base isolation system is subjected to ground acceleration excitations. The performance of …
-
Advanced Modeling and Applications of Smart Materials and Structures on Passive Vibration Suppression
… nonlinear autoregressive exogenous (NARX) model based on a recurrent neural network (RNN) for smart materials with hysteretic behaviors, a phenomenological model for superelastic shape memory alloy (SMA) helical springs, and a mathematical model using quasi-static electromagnetic theories for a …
-
Seismic Performance Comparison of a Fixed-Base Versus a Base-Isolated Office Building
The topic of this thesis is base isolation. The purpose of this thesis is to offer a relative understanding of the seismic performance enhancements that a typical 12-story steel office building can achieve through the implementation of base isolation technology. To reach this understanding, the …
-
Highly deformable confined rubberised concrete elements for seismic applications
… provide a proof-of-concept for a cost-effective base-isolation system made of confined rubberised concrete columns. The first part of this study examines the behaviour of short columns in a one-bay one-storey building made of conventional RC. The building collapsed with the brittle failure of the …
-
Συμβολή στη μελέτη των χαρακτηριστικών της μηχανικής συμπεριφοράς εφεδράνων σεισμικής μόνωσης και διερεύνηση της επιρροής τους στην απόκριση σεισμικά μονωμένων κατασκευών
… approach of the friction coefficient has been based on the elaboration and evaluation of the results of the experiments. In order to complete this part of the research a parametric investigation of the response of a seismic isolated multi-storey building was carried. The properties of the base …
-
Characterization of coupled response of wind-excited base-isolated tall buildings
… alongwind, crosswind and torsional story forces, base bending moments and torque. These advanced models permit wind-induced dynamic response analysis of tall buildings in both frequency and time domains. An analytical framework is presented for estimating stochastic three-dimensional (3D) coupled …
-
Base isolated residential buildings: field tests, laboratory experiments, numerical simulations
… The retrofit was implemented by using a hybrid base isolation system, which consists of high damping rubber bearings and low friction sliding bearings. In 2004, one of the buildings was tested under free vibration field tests. In December 2014, a high damping rubber bearing of the Solarino …
-
PERFORMANCE-BASED ENGINEERING FOR EVALUATION AND RETROFITTING NON-DUCTILE REINFORCED CONCRETE BUILDINGS INCORPORATING AFTERSHOCK HAZARD
Performance-based engineering (PBE) provides a probabilistic tool for assessing the seismic risk and performance of buildings. Only the mainshock hazard has been included in the current PBE framework, although the concern on aftershock hazard has been increased recently. This study develops …
-
Advanced methods for performance-based seismic loss assessment and their application to a base isolated and conventional office building
Seismic base isolation is a well-known seismic protection system that is used to protect structures from earthquakes. The superior seismic performance of base isolated structures has been proven in both analytical simulations and in real earthquakes. However, the use of base isolation in buildings …
-
Improved Seismic Design of Non-structural Components (NSCs) and Development of Innovative Control Approaches to Enhance the Seismic Performance of Buildings and NSCs
… components. Previous studies on NSCs are mostly based on the responses of simplified models of primary systems and components. These models, while providing valuable insight into understanding the influential parameters on NSCs seismic demands and behavioral patterns, may not adequately represent …
-
Αναλυτική διερεύνηση της δυναμικής συμπεριφοράς κτηριακών κατασκευών, σεισμικά μονωμένων με χρήση λικνιζόμενου ορόφου στη βάση
… excitations can be regarded as an innovative base isolation technique. From the 70's to the present, more than 400 buildings with rocking base isolation have been constructed in Russia and the wider region of the former Soviet Union. The rocking columns of these structures are an economical …