Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"Base isolators"”

  1. Study on friction base isolators

    concordia

  2. Experimental investigation of uplift on seismic base isolators /

    Elastomeric rubber bearings reinforced with steel shims, are used to provide structural support in vertical direction and allow horizontal movements for the structure subjected to earthquake and thermal loads. Generally, it is known that tensile stress or uplift may occur when the structure is …

    metu Repository record for Experimental investigation of uplift on seismic base isolators / (opens in a new tab)

  3. Study on friction base isolators for seismic control of low-rise buildings

    Compares the performances of a friction base isolated structure with and without resilient constraints: i.e. with different combinations of slip surfaces and springs, tested on a shake table.

    concordia

  4. PARAMETRIC STUDY OF 1/24 SCALE LAMINATED RUBBER BEARINGS AND LEAD CORE RUBBER BEARINGS

    … designing and fabricating small scale models of base isolators which act as a passive control devices. Scale models of the laminated rubber bearings (with steel plates) and laminated rubber bearings with lead core are fabricated. A procedure to determine the stiffness properties and coefficient …

    ohiolink Repository record for PARAMETRIC STUDY OF 1/24 SCALE LAMINATED RUBBER BEARINGS AND LEAD CORE RUBBER BEARINGS (opens in a new tab)

  5. Recursive block-by-block integral equation solution for transient dynamic analysis with memory-type elements

    … structural response of multi-story nonlinear base isolated buildings for a given seismic event is presented. Using a recursive block-by-block convolution (RBBIEF) solution to the governing nonlinear Volterra integral equation, structural base motion acting through an arbitrary number of …

    nps Repository record for Recursive block-by-block integral equation solution for transient dynamic analysis with memory-type elements (opens in a new tab)

  6. A Comparison Study on Seismically Base Isolated Structures with Different Response Modification Factors

    … of columns of an 8-story hospital building with base isolators based on reduced and unreduced earthquake loads within the scope of TSC 2018. An increase of 4.8% in the column longitudinal reinforcement and 2.0% in the column concrete volume is observed. Additionally, a 0.26% increase in total …

    metu Repository record for A Comparison Study on Seismically Base Isolated Structures with Different Response Modification Factors (opens in a new tab)

  7. Development of a Novel Controllable Seismic Isolation System Based on Negative Stiffness Concept

    … negative stiffness devices (ASNSDs) and other base isolators to contribute new knowledge to the seismic protection field. Firstly, the beneficial effects of nonlinear damping and stiffness on seismic protection are investigated in the form of proposing a modified ASNSD with open-loop control. …

    uts Repository record for Development of a Novel Controllable Seismic Isolation System Based on Negative Stiffness Concept (opens in a new tab) Embargoed

  8. Uncoupled Base Rocking and Shear Mechanisms for Controlling Higher-mode Effects in High-rise Buildings

    … efficiency in limiting higher-mode effects, , base isolation can also be challenging for high-rise buildings due to base isolators being overloaded axially while undergoing significant lateral deformations. Combining both concepts by allowing base-isolated structures to rock at the base as well …

    toronto-retro Repository record for Uncoupled Base Rocking and Shear Mechanisms for Controlling Higher-mode Effects in High-rise Buildings (opens in a new tab)

  9. A Study of Integrated Structural Control Systems for Multi-Hazard Response Mitigation

    … of studies have focused on utilizing TMDs in base isolated structures to reduce resonant motions resulting from multi-hazards (both wind and seismic excitation). A recent study has investigated the wind-induced response of a base isolated (BI) structure with a TLD under wind loading, however, …

    mcmaster Repository record for A Study of Integrated Structural Control Systems for Multi-Hazard Response Mitigation (opens in a new tab)

  10. Hysteretic behaviour of steel- and fibre-reinforced elastomeric isolators fitted with superelastic shape memory alloy wire

    … of earthquake protective mechanisms, elastomeric base isolators, also called rubber bearings (RBs), are one of the most well-known systems that are widely used in buildings and bridges. They can regulate the seismic response of structures, increase the public safety, and reduce the cost of repair …

    ubc Repository record for Hysteretic behaviour of steel- and fibre-reinforced elastomeric isolators fitted with superelastic shape memory alloy wire (opens in a new tab)

  11. Fuzzy Logic Seismic Vibration Control of Buildings

    … device in a controlled manner using an algorithm based on fuzzy logic. First, a semi active fuzzy logic based Tuned Mass Damper (TMD) is developed and tested on a one storey structure subject to free and forced harmonic vibrations and its performance is compared with a passive TMD with the same …

    ohiolink Repository record for Fuzzy Logic Seismic Vibration Control of Buildings (opens in a new tab)

  12. Adaptive Characteristics of Fiber-Reinforced Elastomeric Isolators

    Seismic base isolation has become an increasingly common approach to reduce earthquake induced losses. Base isolation aims to decouple structures, such as buildings or bridges, from strong ground motions through the introduction of a flexible layer, typically located at the foundation. Base …

    mcmaster Repository record for Adaptive Characteristics of Fiber-Reinforced Elastomeric Isolators (opens in a new tab)

  13. Smart Vibration Control of Fluid Storage Tanks via Magnetorheological Dampers

    … application of passive control devices such as base isolators or baffles, to name but a few. The volume of experimental investigations done in this field is not comparable to the theoretical research work. Also, compared to the amount of theoretical research on passive systems, less has been …

    auckland-tech Repository record for Smart Vibration Control of Fluid Storage Tanks via Magnetorheological Dampers (opens in a new tab)

  14. SEISMICALLY RETROFITTING AND UPGRADING RC-MRF BY USING EXPANDED METAL PANELS

    … structural resisting systems for over 30 years based on their capacity in resisting both gravity loads and lateral forces like winds or earthquakes and on low cost of construction. However, there have been still many existing RC-MRFs not designed according to any modern seismic code. This may …

    liege Repository record for SEISMICALLY RETROFITTING AND UPGRADING RC-MRF BY USING EXPANDED METAL PANELS (opens in a new tab)