Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"Baseline removal"”.

  1. Optimization of waveguide enhanced Raman spectroscopy systems

    … performance. The processing includes denoising, baseline removal and deconvolution. The novel multi-frame nonlocal means method has been proven more effective with simpler parameter settings than traditional methods. The asymmetric least square method has been strengthened by incorporating a …

    soton Download PDF for Optimization of waveguide enhanced Raman spectroscopy systems (opens in a new tab)

  2. A Comparison of Standard Denoising Methods for Peptide Identification

    … of using the standard preprocessing methods baseline removal, wavelet smoothing, and binning on spectra with Lewis et. al’s threshold method. We consider individual methods and combinations, using measures of distance from Lewis et. al's scoring function for comparison. Our findings showed …

    etsu Repository record for A Comparison of Standard Denoising Methods for Peptide Identification (opens in a new tab) Download PDF for A Comparison of Standard Denoising Methods for Peptide Identification (opens in a new tab)

  3. A Raman spectroscopic analysis of thin-films of carbon

    … namely: (1) acquisition, (2) smoothing, (3) baseline identification, (4) baseline removal, (5) peak decomposition, and (6) evaluation of ID/IG. The second aspect of this study aims to examine as to whether the form of the Raman spectrum is shaped by the location of the sample within the …

    ubc Repository record for A Raman spectroscopic analysis of thin-films of carbon (opens in a new tab) Download PDF for A Raman spectroscopic analysis of thin-films of carbon (opens in a new tab)

  4. Investigations of atherosclerotic coronary arteries by confocal raman microspectroscopy

    … algorithms were developed and tested for baseline removal, normalization and smoothing of Raman spectra obtained. Key analysis involving component analysis and generalized two-dimensional (2D) correlation followed. A model for chemical component analysis of eighteen major biochemicals …

    ubc Repository record for Investigations of atherosclerotic coronary arteries by confocal raman microspectroscopy (opens in a new tab) Download PDF for Investigations of atherosclerotic coronary arteries by confocal raman microspectroscopy (opens in a new tab)

  5. Comparative Evaluation of Bending Resistance and Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study

    … to 35 N·cm and retightened after 10 minutes. Baseline removal torque values (RTV) were recorded. Specimens were then subjected to cyclic loading for 100,000 cycles at 100 cycles/min (approximately 1.67 Hz) under 65–120 N at 30° off-axis, followed by post-cyclic RTV measurement. After …

    wvu Repository record for Comparative Evaluation of Bending Resistance and Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study (opens in a new tab)

  6. Elucidating the Complex Signaling Events Driving Intestinal Stem Cell Plasticity Following Injury

    … (PI3K) signaling pathway, p85α, in IECs. At baseline, removal of p85α led to increased activation of PI3K/Akt, as seen through elevations in phosphorylated PTEN, Akt, and GSK3β. The consequence of the persistent activation was a shifting of cells out of the stem cell niche, into more …

    uky-thes Repository record for Elucidating the Complex Signaling Events Driving Intestinal Stem Cell Plasticity Following Injury (opens in a new tab)

  7. Analysis of beat-to-beat QT interval variability in 12-lead ECG signals.

    … detection algorithm and implements an efficient baseline removal algorithm in the existing template matching approach. (vi) Effects of T-wave amplitude and ECG lead on beat-to-beat QTV in patients with Myocardial Infarction (MI) compared to healthy subjects are studied and suggest that increased …

    adelaide Repository record for Analysis of beat-to-beat QT interval variability in 12-lead ECG signals. (opens in a new tab)

  8. An algorithm for extracting the PPG Baseline Drift in real-time

    … be extracted. One such challenge is removing the baseline drift of the signal, which is caused by respiratory rate, muscle tremor and physiological changes within the body as a response to various stimuli. Over the years there have been many methods developed in order to condition the signal such …

    edithcowan Repository record for An algorithm for extracting the PPG Baseline Drift in real-time (opens in a new tab)

  9. Preventing Or Mitigating The Irreversible RO Membrane Fouling Caused By Dissolved Organic Matter And Colloidal Materials During Surface Water Treatment

    … sedimentation, and ultrafiltration, lead to the removal of 42.2% and 59.44% of DOM on using PACl and FeCl3 as coagulants, respectively, indicating improvement over the average baseline removal of 30% under non-optimized conditions. In addition, the removal of more than 90% turbidity (with PACl, …

    nodak Repository record for Preventing Or Mitigating The Irreversible RO Membrane Fouling Caused By Dissolved Organic Matter And Colloidal Materials During Surface Water Treatment (opens in a new tab)