Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"Beam collimation"”.

  1. Optical characterization of nanostructured plasmonic polarizers

    … spot size, as well as control over the incident beam collimation and polarization state. The electrical response of micro-polarizing structures fabricated on photodiodes was also characterized using this system. Guidance on how to perform such measurements is presented. Simulation of the optical …

    colo-mines Repository record for Optical characterization of nanostructured plasmonic polarizers (opens in a new tab)

  2. A low-cost man-portable free-space optics communication device for ethernet applications

    … the working range of the FSO. By improving beam collimation, adding precise mechanical movement and using assisting tools and techniques, the FSO network link was successfully established and tested over larger distances using 100Mbps. The maximum distance that could be achieved, with the …

    nps Repository record for A low-cost man-portable free-space optics communication device for ethernet applications (opens in a new tab)

  3. Design and Applications of Printed-circuit-board Huygens' Metasurfaces

    … devices are presented. Applications including beam collimation, angle doubling, and perfect refraction are investigated. Additionally, realization of printed-circuit-board prototypes are detailed with designs utilizing stacked-layer and wire-loop structures. Throughout the different …

    toronto-retro Repository record for Design and Applications of Printed-circuit-board Huygens' Metasurfaces (opens in a new tab)

  4. Chip-scale atomic beam production, collimation and its applications

    Atomic beams are a key technology for realizing navigation-grade timekeeping and inertial sensing instruments. Miniaturization of atom beam technology can enable new quantum sensor architectures benefitting from foundry production and microfabrication approaches. This thesis paves the way towards …

    gatech Repository record for Chip-scale atomic beam production, collimation and its applications (opens in a new tab)

  5. Study of Low Energy Electron-Impact Induced Ionization and Fragmentation of Uracil

    … a collision chamber and a flight tube. A beam of uracil is generated in the expansion chamber, passes through a skimmer and crossed with a pulsed beam of low energy electrons in the collision chamber. The electron gun has a pulse width of 1 μs providing the necessary time of flight …

    maynooth Download PDF for Study of Low Energy Electron-Impact Induced Ionization and Fragmentation of Uracil (opens in a new tab)

  6. High-accuracy characterization of optical components : detectors, coatings and fibers

    … plane and incidence angle and quality of beam collimation to be taken into account. The spectral reflectance and transmittance measurements are carried out for incidence angles varying between normal and Brewster's angle and the results are compared. For the first time, the reached …

    aalto Repository record for High-accuracy characterization of optical components : detectors, coatings and fibers (opens in a new tab)

  7. Analysis and design of optical guided-wave devices for quasi-phasematched second harmonic generation and Bragg deflection

    Integrated optics-based approaches to beam steering, beam shaping, beam collimation, and quasi-phasematched (QPM) second harmonic generation (SHG) of light offer significant advantages over conventional approaches based on bulk optics. The research in this dissertation addresses the analysis and …

    arizona-thes Repository record for Analysis and design of optical guided-wave devices for quasi-phasematched second harmonic generation and Bragg deflection (opens in a new tab)

  8. Plasmonic control of light emission for enhanced efficiency and beam shaping

    … NP-film system, and the demonstration of beam collimation and unidirectional diffraction utilizing a similar geometry. These results may find novel applications in the emerging field of solid-state smart lighting.

    bu Repository record for Plasmonic control of light emission for enhanced efficiency and beam shaping (opens in a new tab)

  9. Design and evaluation of a laser ion source for TITAN to measure 222Rn daughter product abundances

    … addresses several challenges, such as ion beam collimation, steering, filtering, and raster scanning. Quadrupole bender and space charge effects cause beam expansion and off-axis deflection, necessi-tating the use of Pierce electrodes, steering elements, and Einzel lenses to maintain beam …

    calgary Repository record for Design and evaluation of a laser ion source for TITAN to measure 222Rn daughter product abundances (opens in a new tab)

  10. Ελαχιστοποίηση της ακτινικής επιβάρυνσης ασθενών που υποβάλλονται σε πολυτομική υπολογιστική τομογραφία μέσω βελτιστοποίησης των παραμέτρων σάρωσης

    … at the console from -24% to 14%. Differences in beam collimation resulted in 50% variation in the CTDIW in the body phantom and 60% in the head phantom. In clinical practice effective dose values to pediatric patients are 2 5 to 10 times lower than in adults due to the adaptation of tube current. …

    greece Repository record for Ελαχιστοποίηση της ακτινικής επιβάρυνσης ασθενών που υποβάλλονται σε πολυτομική υπολογιστική τομογραφία μέσω βελτιστοποίησης των παραμέτρων σάρωσης (opens in a new tab)

  11. Lazerio pluošto astigmatizmo atsirandančio neašiniuose veidrodiniuose teleskopuose kompensavimas /

    … C. N. Man paper „Design of a low-loss off-axis beam expander” suggested idea allows to compensate astigmatism, created by mirror telescope made of concave and convex mirrors, either the incident beam is collimated or not. In this paper for beam quality assessment is mainly used Strehl ratio that …

    vilnius Repository record for Lazerio pluošto astigmatizmo atsirandančio neašiniuose veidrodiniuose teleskopuose kompensavimas / (opens in a new tab)

  12. A tomographic imaging system for pneumatic conveyors using optical fibres.

    … on preparation of the ends of the optical fibre, beam collimation and design of the transmitter and receiver circuits.The optical sensors are evaluated singly and as a tomographic array. Results relating to concentration measurement are presented for solids flow using sand with a mean of 300 …

    sheffield-hallam Download PDF for A tomographic imaging system for pneumatic conveyors using optical fibres. (opens in a new tab)

  13. Investigation of a Cluster of High-Power Helicon Thrusters for Advanced In-Space Electric Propulsion Applications

    … a single monolithic thruster in terms of beam collimation and exit velocities. The clustered HPH experiment operated at power levels ≥100 kW and could produce high energy, collimated plasma beams for in-space propulsion and beamed momentum applications. For this dissertation research, …

    washington Repository record for Investigation of a Cluster of High-Power Helicon Thrusters for Advanced In-Space Electric Propulsion Applications (opens in a new tab)

  14. Characterizations and Diagnostics of Compton Light Source

    … At the HIGS, a Free-Electron Laser (FEL) beam is Compton scattered with an electron beam in the Duke storage ring to produce an intense, highly polarized, and nearly monoenergetic gamma-ray beam with a tunable energy from about 1 MeV to 100 MeV. This unique gamma-ray beam has been used in …

    duke Repository record for Characterizations and Diagnostics of Compton Light Source (opens in a new tab)

  15. Development and Application of Realistic Anatomical and Imaging Models for Virtual Clinical Trials in Computed Tomography

    … this chapter was to investigate the effects of beam collimation and pitch on image quality in computed tomography under different respiratory and cardiac motion levels. A realistic human model with added lung lesions was used to cardiac and respiratory motions. Each case was imaged using DukeSim …

    duke Repository record for Development and Application of Realistic Anatomical and Imaging Models for Virtual Clinical Trials in Computed Tomography (opens in a new tab)

  16. Design and development of photonic devices using direct laser writing techniques

    … the thesis emphasizes the importance of precise beam spot positioning and control during irradiation. For this purpose it proposes an autofocus system for controlling the diode based laser writing process. Also, presents an extensive study on customizing a diode laser module to optimize beam …

    greece Repository record for Design and development of photonic devices using direct laser writing techniques (opens in a new tab)

  17. Holographic transmit reflect array at 5.8 GHz for wireless power transfer in the Fresnel Zone

    … successfully collimate the incoming power into beams at 10-meter, 5-meter, 3-meter, and 10-meter focal points respectively.

    gatech Repository record for Holographic transmit reflect array at 5.8 GHz for wireless power transfer in the Fresnel Zone (opens in a new tab)

  18. Radiation Dose and Diagnostic Accuracy in Pediatric Computed Tomography

    … <p></p> <p>The effects of bowtie filter and beam collimation on dose and risk were small compared to the effects of helical pitch and tube potential. The effects of any scan parameter were patient size-dependent, which could not be reflected by the difference in volume-weighted CT dose index …

    duke Repository record for Radiation Dose and Diagnostic Accuracy in Pediatric Computed Tomography (opens in a new tab)

  19. Development of an AI-assisted computational method for the determination of individual patient radiation dose from computed tomography examinations

    … characteristics of the CT scanner, such as beam collimation, fan angle, spectrum of the beam and rotation time, among others. Data preprocessing was performed using Python notebooks and available, open-source, Python libraries. A total of 11424 DICOM CT images and an equal number of ground …

    greece Repository record for Development of an AI-assisted computational method for the determination of individual patient radiation dose from computed tomography examinations (opens in a new tab)