Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 72 for “"Beam hardening"”
-
Automated Beam Hardening Correction for Myocardial Perfusion Imaging using Computed Tomography
… exam for invasive coronary angiography. However, beam hardening (BH) artifacts prevent accurate blood flow assessment and the reduction of false positive identification of coronary disease in MPI-CT. BH occurs when a poly-energetic x-ray beam passes through an attenuating material. Depending on …
-
Micro-Computed Tomography Semi-Empirical Beam Hardening Correction: Method And Application To Meteorites
… data can be susceptible to artifacts such as beam hardening, a consequence of high X-ray attenuation in these dense materials. A semi-empirical correction method for beam hardening and scatter that can be straightforwardly applied to available biomedical scanners is proposed and evaluated. …
-
The influence of scatter and beam hardening in X-ray computed tomography for dimensional metrology
… measurements. Scattered radiation and beam hardening are two phenomena that are well-known to severely degrade the quality of cone-beam CT data; however, the impact they have on dimensional measurements is not well understood. The aim of this work is to better understand how scatter and …
-
Beam Hardening and Scatter Artifact with Metal Objects Inside and Outside the Field of View in CBCT Imaging
… test, two observers rated paired images for beam hardening/scatter artifacts. Results: The Wilcoxon signed rank test showed no difference in the SD of grayscale values with the metal objects inside or outside the FOV (p=.2882). However, a subjective comparison of the two image groups (metal …
-
Bone Densitometry using CT Imaging
… from CT imaging requires a consideration of beam hardening artifacts. This effect, if not corrected, can cause severe errors in the measurements which result in inaccurate calculations. Dual energy correction as described by Alvarez (1976) is capable of eliminating beam hardening artifacts by …
-
Data-driven Image Quality Improvements for Cone-Beam Computed Tomography in Radiation Therapy
… a computed tomography (CT) image. On-board cone-beam CT (CBCT) images cannot be used for a daily-updated plan because of their insufficient image quality. The aim of this thesis is to reduce two artifacts responsible for image quality loss: scatter and beam hardening. Novel deep learning-based …
-
Effect of metallic restoration artifacts on maxillofacial cone beam computed tomography images.
… dental restorations on maxillofacial cone beam computed tomographic (CBCT) images can render certain areas unsuitable for diagnosis. It was hypothesized that image quality due to HDO artifacts was affected by CBCT acquisition parameters and the number and configuration of HDO. Simulated …
-
Timing-Pulse Measurement and Detector Calibration of the OsteoQuant
… two issues: motion-detector timing and dead-time/beam-hardening corrections.During translation, the motion-control system of the scanner repositions the sourceand detector by small intervals. However, the detector collects photon counts asynchronously with respect to the motor-timing pulses and …
-
The influence of surface determination in x-ray computed tomography
… mode in VGStudio’ (VG) algorithms, under beam hardening and noise effect. SD thresholding parameters were optimised by Taguchi methods when evaluating different types of surface conditions, including smooth and rough surfaces. Canny presented the worst performance during the measurement of …
-
A Survey of CT Phantom Considerations for the Study of Blooming Artifacts as Observed in CT Coronary Angiography Studies: A Preliminary Study
… angiography in routineclinical practice. A beam hardening phantom system was developed to determine thedependence of blooming with respect to measured density in Hounsfield Units (HU), of5mm diameter plaques. Custom software was developed to provide reproducibleobjective measurements of …
-
Characterization and Improvement of a Cone-Beam CT Scanner for Quantitative Imaging
… in different fields. In our case, the cone-beam CT scanner is used in the industrial field for qualitative and quantitative assessment of Procter and Gamble products. The Flash CT scanner, on which we do our research, has a microfocus x-ray tube, a detector size of 30 cm x 40 cm and a …
-
DETECTION AND QUANTIFICATION OF CORONARY CALCIUM FROMDUAL ENERGY CHEST X-RAYS: PHANTOM FEASIBILITY STUDY
… and the role of potential confounds such as beam hardening, scatter estimation, cardiac motion, and pulmonary artery pulsation. For the DE calcium signal, we will consider quantification, as compared to CT calcium score. We created digital 3D phantoms including heart, lung, coronary calcium, …
-
Investigation of sub-core scale fluid flow behaviour within heterogeneous sandstones : the role of deformation bands
… artefacts-free CT images are needed. Beam hardening artefact, in cylindrical-shaped samples, increases the X-ray attenuation values with increasing distance from the centre. A new beam hardening correction technique was developed using a post-processing linearization procedure on the …
-
Automated Modelling of Cortical Bone from Clinical CT
… for inaccuracies in CBM measurements caused by beam hardening effects to be considered for the first time: I show that beam hardening leads to an underestimation in cortical thickness and an overestimation in trabecular BMD and that these inaccuracies can be reduced through adjustments to the …
-
Phase contrast imaging with a laboratory-based microfocus X-ray source
… of monochromation reduces phase contrast due to beam hardening, so this method is unsuitable for phase imaging with this system. By increasing sample thickness, phase contrast is seen to plateau at a certain thickness, dependant on X-ray energy, revealing a practical limitation of the system. …
-
System Optimization and Patient Translational Motion Correction for Reduction of Artifacts in a Fan-Beam CT Scanner
… For our laboratory prototype CT system, a fan-beam/cone-beam focal high-resolution computed tomography (fHRCT) scanner, the major artifacts that affect image quality are distortions due to errors in the reconstruction algorithm's geometric parameters, ring artifacts caused by uncalibrated …
-
MicroCT of Coronary Stents: Staining Techniques for 3-D Pathological Analysis
… sensitivity and specificity while reducing beam-hardening artifact from stent struts. The developed staining techniques included iodine-potassium iodide, phosphomolybdic acid, and phosphotungstic acid, all of which bind to soft tissue and improve image quality through their ability to …
-
Caudad to cranial versus cranial to caudad CT scanning of the thorax: a comparison of two protocols
… compares artifact (motion at the lung bases and beam hardening from the superior vena cava and subclavian vein), clarity of vessels (hilar vessels, great vessels and aorta) and clarity of the nodal systems (stations 2R,2L,4R,5,6 and hilar) in the caudad to cranial and cranial to caudad direction …
-
Theory, Experiments, and Image Recovery Algorithms for X-ray Interferometry
… and correcting spectral artifacts resulting from beam hardening. Methods: The modulated phase grating interferometer (MPGI) is a potential solution for reducing X-ray dose by eliminating the analyzer grating used in alternative interferometer designs, including the Talbot-Lau interferometer (TLI). …
Page 1 of 4