Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 125 for “"Beam intensity"”.

  1. Solid state x-ray detector calibration techniques and LINAC beam intensity measurements

    … been used to measure the the integrated electron beam current only. The measured x-ray flux and the known inner shell ionization cross sections are used to obtain measurements of dark currents of the order of ten to the minus fourteenth amperes. The same arrangement allows continuous, in-situ …

    nps Repository record for Solid state x-ray detector calibration techniques and LINAC beam intensity measurements (opens in a new tab)

  2. Beam intensity effects on the \(K^+ \rightarrow \pi^+v\bar{v}\) measurement at NA62

    … of particles (kaons) in an unseparated hadron beam. The optical design for a new CEDAR detector optimised to work with hydrogen as radiator gas, Cedar-H, is presented. Cedar-H has been commissioned and installed into NA62 with more than satisfactory performances and a 20% increase in light …

    birmingham Download PDF for Beam intensity effects on the \(K^+ \rightarrow \pi^+v\bar{v}\) measurement at NA62 (opens in a new tab)

  3. Studies of supersonic beam formation at low temperatures for a polarized helium 3 ion source

    The formation of a molecular beam using a miniature supersonic nozzle source is discussed. The results of operation at room, liquid nitrogen and liquid helium temperatures of a supersonic nozzle system designed for use in a polarized helium³ ion source are presented. It is shown that helium⁴ beam …

    ubc Repository record for Studies of supersonic beam formation at low temperatures for a polarized helium 3 ion source (opens in a new tab) Download PDF for Studies of supersonic beam formation at low temperatures for a polarized helium 3 ion source (opens in a new tab)

  4. Multiple Objective Linear Programming in Radiotherapy Treatment Planning

    The aim of intensity modulated radiation therapy (IMRT) is to kill tumor cells while at the same time protecting the surrounding tissue and organs from the damaging effect of radiation. To achieve these goals computerized inverse planning systems are used. Given the number of beams and beam …

    auckland-ms Repository record for Multiple Objective Linear Programming in Radiotherapy Treatment Planning (opens in a new tab)

  5. Photoinduced dichroism in amorphous As₂Se₃ thin film

    … in amorphous As₂Se₃ induced by a polarized beam of near band-gap light (λ = 632.8 nm) was measured in films that ranged in thickness from 0.25 µm to 1.93 µm. Most noncrystalline materials are initially isotropic and homogeneous. When amorphous As₂Se₃ (a chalcogenide glass) absorbs an intense …

    sask Repository record for Photoinduced dichroism in amorphous As₂Se₃ thin film (opens in a new tab)

  6. Observation and analysis of optical transition radiation at the NPS linac and its use for diagnostics of electron beams

    … for extensive analysis of the captured electron beam spot OTR patterns. The equipment is capable of measuring relative intensities to better than 1% for a constant source image. With beam energies of nearly 100 MeV the captured OTR images show an unexpected assymetry in the beam intensity …

    nps Repository record for Observation and analysis of optical transition radiation at the NPS linac and its use for diagnostics of electron beams (opens in a new tab)

  7. Electrical resistivity of thin films of potassium

    … films were deposited on a pyrex substrate from a beam of potassium vapor in a vacuum chamber which had a pressure less than 5 x 10-8 mm of Hg. The film thickness, in each case, was computed from a known beam intensity, exposure time, and film density. A surface ionization detector was used to …

    iastate Repository record for Electrical resistivity of thin films of potassium (opens in a new tab)

  8. Relaxation dynamics in borate glass formers probed by photon correlation at the microscopic and macroscopic length scale

    … results and independent of the incoming beam intensity in the undercooled liquid phase; are instead temperature independent and show a definite dependence on the X-ray beam intensity in the glass. We are therefore witnessing an atomic dynamics induced by the X-ray beam. Furthermore, we …

    trento Repository record for Relaxation dynamics in borate glass formers probed by photon correlation at the microscopic and macroscopic length scale (opens in a new tab)

  9. OPTIMIZATION OF ELECTROMAGNETIC WAVE PROPAGATION THROUGH A HETEROGENEOUS LIQUID CRYSTAL LAYER

    … engineer a material that can reduce transmitted beam intensity by the greatest factor, we look to liquid crystals. They have great potential to provide a starting point to engineer a material in order to show increased protection of DoD assets from high-energy beam weapons. We first develop …

    nps Repository record for OPTIMIZATION OF ELECTROMAGNETIC WAVE PROPAGATION THROUGH A HETEROGENEOUS LIQUID CRYSTAL LAYER (opens in a new tab)

  10. Spinduliuotės formavimo faziniu ,,top-hat" keitikliu ir optimizavimo tyrimas /

    … to process laser radiation, such as lenses, beamforming transducers, beam expanders, and other optical systems. In this work, we will explore what to do with a laser beam whose intensity has a plentiful intensity distribution to make its beam intensity as uniform as possible and save as much …

    vilnius Repository record for Spinduliuotės formavimo faziniu ,,top-hat" keitikliu ir optimizavimo tyrimas / (opens in a new tab)

  11. A spectrometer for study of neutron activation of beryllium-7 as a function of energy

    … of 13 microseconds per meter and monochromatic beam intensity up to 10(4)n/cm(2)-sec in the range 0.012-0.400 ev has been constructed for study of the activation cross section of Be(7) as a function of energy in the thermal region. First preliminary results using ZnS(Ag) as a detector suggest …

    nps Repository record for A spectrometer for study of neutron activation of beryllium-7 as a function of energy (opens in a new tab)

  12. Design of a nonlinear quasi-integrable lattice for resonance suppression at the University of Maryland Electron Ring

    … to myriad resonances and instabilities. At high beam intensity, uncontrolled resonance-driven losses can deteriorate beam quality and cause damage or radio-activation in beam line components and surrounding areas. This is currently a major limitation of achievable current densities in …

    maryland Repository record for Design of a nonlinear quasi-integrable lattice for resonance suppression at the University of Maryland Electron Ring (opens in a new tab)

  13. Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT

    Equispaced beam arrangements are typically used for IMRT plans. This beam arrangement provides adequate dose coverage to the target while sparing dose to other structures. However, an equispaced beam arrangement may not provide the best dose coverage to the target while sparing dose to the other …

    gatech Repository record for Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT (opens in a new tab)

  14. A LASER FOR OPHTHALMOLOGICAL COAGULATION

    … the pumping source and the active medium.. Laser beam intensity and diameter control mechanisms, and a pilot light system for directing and focusing purposes, have been incorporated into the laser coagulating unit. Some aspects of light coagulation and the basic principles of laser operation are …

    sask Repository record for A LASER FOR OPHTHALMOLOGICAL COAGULATION (opens in a new tab)

  15. Application of machine learning for energy reconstruction in the ATLAS liquid argon calorimeter

    The beam intensity of the Large Hadron Collider will be significantly increased during the Phase-II long shut down of 2024-2026. Signal processing techniques that are used to extract the energy of detected particles in ATLAS will suffer a significant loss in performance under these conditions. This …

    uvic Repository record for Application of machine learning for energy reconstruction in the ATLAS liquid argon calorimeter (opens in a new tab)

  16. Numerical simulation of high intensity laser drilling of metals

    … an effective computer program to simulate high beam intensity laser drilling of metals. The study consists of four parts. In the first part, laser history and laser drilling simulation history are reviewed. In the second part, the mathematical formulation is described, the physical model of …

    ut-knoxville Repository record for Numerical simulation of high intensity laser drilling of metals (opens in a new tab)

  17. Infrared laser-induced photolysis of ethylene.

    … has been studied. The influence of pressure, beam intensity, and irradiation time on the product distribution was investigated. Isotopic mixtures were also irradiated to gain insight into the mechanism and to investigate isotopic selectivity of the process. Changes in mechanism were apparent …

    ottawa-retro Repository record for Infrared laser-induced photolysis of ethylene. (opens in a new tab)

  18. Intensity-dependent effects in the Accelerator Test Facility 2 and extrapolation to future electron-positron linear colliders

    … these linear colliders require a nanometer beam size at the Interaction Point (IP). The electron and positron beams are transported inside the Beam Delivery Systems (BDS) from the linear accelerators (LINACS) to the IP. The beam is focused by two strong quadrupoles in the Final Focus System …

    oxford Repository record for Intensity-dependent effects in the Accelerator Test Facility 2 and extrapolation to future electron-positron linear colliders (opens in a new tab)

  19. Fluorine-18 Production for PET and an Investigation of the Fluorine-18(p,alpha)Oxygen-15 Reaction with a Radioactive Beam

    … important in the emerging field of a radioactive beam development for nuclear reaction studies. Aside from increasing some PET radiopharmaceutical yields by factors of 2-20, the present work made possible a factor of 10 ^3-10^4 improvement in ^{18}F ion beam intensity over previously published …

    mankato Repository record for Fluorine-18 Production for PET and an Investigation of the Fluorine-18(p,alpha)Oxygen-15 Reaction with a Radioactive Beam (opens in a new tab)

Page 1 of 7